← Back to Woodburn

Document Woodburn_doc_90e4804dbe

Full Text

WILDFIRE SMOKE PROTECTION PLAN 1. Purpose The purpose of this plan is to protect City employees from the hazards of wildfire smoke exposure. 2. Scope The standards and guidelines of this policy apply whenever an employee performs work activities and the air quality index (where the ambient air concentration for PM2.5 is at or above 35.5 ug/m3) is above 101. It does not apply when an employee performs work activity in: Enclosed buildings and structures in which the air is filtered by a mechanical ventilation system and the windows, doors, bays, and other exterior openings are kept closed, except when it is necessary to open doors to enter or exit. Enclosed vehicles in which the air is filtered by a cabin air filter and the windows, doors, and other openings are kept closed, except when it is necessary to open doors to enter and exit. Employees driving or operating buses and other enclosed vehicles used for transit systems where doors are frequently opened to board and de-board passengers are NOT exempt from these rules. When any other applicable standard addresses other hazards that may be present, both standards shall be followed. Where the requirements of one standard are more restrictive than the other, the more stringent requirements shall be followed. 3. Definitions Air Quality Index – The Air Quality Index (AQI) was developed by the US Environmental Protection Agency as an indicator of overall air quality and is based on the five criteria pollutants regulated under the Clean Air Act: ground-level ozone, particulate matter, carbon monoxide, sulfur dioxide, and nitrogen dioxide. For the purposes of this rule, the AQI can be determined by the following means: ---PAGE BREAK--- • Check the current ambient air concentration for PM2.5 from the U.S. EPA AirNow website, the Oregon Department of Environmental Quality’s air quality website, or equivalent source; or • Obtain the current concentration in ambient air for PM2.5 directly from the U.S. EPA (via AirNow app), the Interagency Wildland Fire Air Quality Response Program, or the Oregon Department of Environmental Quality’s air quality website; or • Directly measure the work location ambient air concentration for PM2.5 in accordance with the manufacturer’s instructions for the testing device used; or • If all of the previous methods are not practical, use the 5-3-1 Visibility Chart below to estimate the current air quality and corresponding AQI risk category Distance you can see* You are: OR You have • An adult • A teenager • An older child • Age 65 and over • Pregnant • A young child • Asthma • Respiratory illness • Lung or heart disease 5 miles check visibility minimize outdoor activity minimize outdoor activity 3 miles minimize outdoor activity stay inside stay inside 1 mile stay inside stay inside stay inside Greater Hazard – The ability of an employer to demonstrate that compliance with the requirements of the rule would expose an employee to a hazard associated with a substantially more serious injury or illness, thereby providing a narrow exception to the rule to the degree that the greater hazard exists. An example of a greater hazard in relation to the use of non- flame-resistant filtering face piece respirators would include potential facial burns to a qualified employee working within the minimum approach distance (MAD) of an energized high voltage electrical system where flame resistant clothing is required. ---PAGE BREAK--- NIOSH – The National Institute for Occupational Safety and Health of the United States Centers for Disease Control and Prevention. NIOSH tests and approves respirators for use in the workplace. PM2.5 – Solid particles and liquid droplets suspended in air, known as fine particulate matter, with an aerodynamic diameter of 2.5 micrometers or smaller and measured in micrograms per cubic meter (ug/m3). Sensitive Groups – People with pre-existing health conditions and those who are sensitive to air pollution who are among those likely to experience health problems from exposure to wildfire smoke. Examples of sensitive groups include: people with lung disease such as asthma or chronic obstructive pulmonary disease (COPD), including bronchitis and and those who smoke; people with respiratory infections, such as pneumonia, acute bronchitis, bronchiolitis, cold, flu, or those with or recovering from COVID-19; people with existing heart or circulatory problems, such as irregular heartbeat, congestive heart failure, coronary artery disease, angina, and those who have had a heart attack or stroke; children under 18 years old, and adults over age 65; pregnant women; people with diabetes; and people with other medical or health conditions which can be exacerbated by exposure to wildfire smoke as determined by a physician. Wildfire Smoke – Emissions from unplanned fires in wildlands, which may include adjacent developed and cultivated areas to which the fire spreads or from where it originates. Wildlands – Uncultivated and sparsely populated geographical areas covered primarily by grass, brush, trees, slash, or a combination thereof. 4. Policy It is the policy of the City of Woodburn to follow and adhere to Oregon OSHA rules addressing employee exposure to wildfire smoke. Therefore, the City implements the following smoke- related practices to help prevent employees from suffering from exposure to wildfire smoke while at their work site(s). 5. General Guidelines 5.1. Monitoring and Communicating Air Quality Supervisors shall monitor air quality and communicate wildfire smoke hazards when the concentrations in ambient air for PM2.5 is at or above 35.5 ug/m3 (AQI 101), before employees are exposed to it. This means, supervisors shall notify employees: When work location ambient air concentration for PM2.5 is at or above • AQI 101 - 276; • AQI 277 - 848; ---PAGE BREAK--- • AQI 849 or above; or • drops below levels requiring protective measures Supervisors shall also enable and encourage employees to inform the City if the air quality improves or worsens; and if they experience severe health that may be the result of wildfire smoke exposure such as asthma attacks, difficulty breathing, and chest pain occur. 5.2. Exposure Controls Whenever employee exposure to PM2.5 is at or above 35.5 ug/m3 (AQI 101), the supervisor must maintain a sufficient number and sizes of NIOSH-approved filtering facepiece respirators that effectively protect wearers from PM2.5 at each work location where employees are exposed. Such respirators shall be provided at no cost and be readily available for voluntary use to all exposed workers at their request. City shall also use engineering or administrative controls to reduce employee PM2.5 exposure to less than AQI 277 whenever feasible. Engineering controls include providing work in enclosed buildings, structures, or vehicles where the air is adequately filtered. Administrative controls include relocating work to an outdoor location where the current ambient air concentration of PM2.5 is less than AQI 277 or changing work schedules to a time when ambient air concentration of PM2.5 is less than AQI 277. Whenever employee exposure to PM2.5 is at or above AQI 277 even after the application of engineering and administrative controls, employees must wear NIOSH-approved filtering facepiece respirators in accordance with Protection from Wildfire Smoke Standards in OAR 437- 004-9791 Protection from Wildfire Smoke Appendix A. Whenever employee exposure to PM2.5 is at or above AQI 849, even after the application of engineering and administrative controls, employees must wear NIOSH-approved respirators for mandatory use by implementing a Respirator Protection Program in accordance with 29CFR 1910.134 or OAR [PHONE REDACTED] N95s can be substituted for NIOSH-approved filtering face piece respirators for exposures below AQI 848. For exposures at AQI 849and above, NIOSH-approved respirators must be worn. The attached Appendix A includes workplace guidance on the proper use of- and fitting for filtering face piece respirators. 6. Training All employees, including new employees, supervisory, and non-supervisory employees will be trained in the following topics, before employees begin work that can reasonably be ---PAGE BREAK--- anticipated to expose employees to a workplace ambient air concentration for PM2.5 at or above 35.5 ug/m3 (AQI 101). Training shall include at least the following elements: of wildfire smoke exposure, including: Eyes: burning sensations, redness, and tearing of the eyes caused by irritation and inflammation of the eyes that can temporarily impair one’s vision. Respiratory system: runny nose, sore throat, cough, difficulty breathing, sinus irritation, wheezing, shortness of breath; Fatigue, headache, irregular heartbeat, chest pain. The potential health effects of wildfire smoke, including increased risk of health effects to sensitive groups; The definition of sensitive groups as defined under section The employee’s right to report health issues related to wildfire smoke exposure and obtain medical treatment for workplace exposure to wildfire smoke without fear of retaliation; The procedures the supervisor must follow if an employee exhibits severe of wildfire smoke exposure, including appropriate emergency response procedures; How employees can obtain the current and forecasted ambient air concentration for PM2.5 and equivalent AQI level; How to effectively operate and interpret any air quality monitoring device provided by the employer to comply with these rules, for each employee designated by the employer to operate such devices; The employer's methods to protect employees from wildfire smoke; The employer's communication system for wildfire smoke hazards covered under section and The importance, limitations, and benefits of using a filtering face piece respirator when provided by the employer, and how to properly put them on. 7. References OAR [PHONE REDACTED] and OAR [PHONE REDACTED] Protection from Wildfire Smoke Appendix A: 8. Review of Policy and Procedures This policy will be reviewed annually or as state and federal regulations are revised and necessitate a change in the policy or procedures. ---PAGE BREAK--- Adopted: August 2021 Revised: September 2024 ---PAGE BREAK--- Appendix Mandatory Workplace Guidance for THE USE OF FILTERING FACEPIECE RESPIRATORS TO ADDRESS WILDFIRE SMOKE This appendix applies only to employers that require NIOSH-approved filtering face piece respirators, including N95, P95, and R95, to be used by their workers for protection exclusively for wildfire smoke exposures when workplace ambient air concentrations of PM2.5 is at or aboveAQI 277 but below PM2.5 AQI 849. Filtering face piece respirators are disposable, negative-pressure, air purifying respirators where an integral part of the face piece or the entire face piece is made of air contaminant filtering material. This appendix does not apply to other types of respirators, including but not limited to elastomeric tight-fitting respirators, nor does it apply to situations where workers use filtering face piece respirators for protection against air contaminants other than PM2.5 from wildfire smoke. Employers whose workers are required to wear filtering face piece respirators to protect against wildfire smoke exposures when workplace ambient air concentrations of PM2.5 is at or above AQI 277 must develop either a respiratory protection program in accordance with the Respiratory Protection Standard (29 CFR 1910.134); or a Wildfire Smoke filtering face piece respiratory protection program in accordance with the following requirements when workplace ambient air concentrations of PM2.5 are under AQI 849: Employee training. Employers must ensure that employees wearing filtering face piece respirators are trained in the proper use of the respirators, including putting them on and removing them, any limitations on their use, how to care for the respirator, and the ability to demonstrate a seal check as described in below. Filtering face piece respirator user seal check. Each employee who uses a filtering face piece respirator must perform a user seal check to ensure that the respirator is properly sealed to the face is achieved each time the respirator is put on. Either the positive or negative pressure checks listed in this appendix or the respirator manufacturer’s recommended user seal check method must be used. 1. Instructions for positive pressure user seal check. Once you have properly donned the respirator, place your hands over the face piece, covering as much surface area as possible. Exhale gently into the face piece. The face fit is considered satisfactory if a slight positive pressure is being built up inside the face piece without any evidence of outward leakage of air at the seal. Examples of evidence that it is leaking could be the feeling of air movement on your face along the seal of the face piece, fogging of your glasses, or a lack of pressure being built up inside the face piece. If the particulate respirator has an exhalation valve, then performing a ---PAGE BREAK--- positive pressure check may not be possible. In such cases, a negative pressure check must be performed. 2. Instructions for negative pressure user seal check. Negative pressure seal checks are typically conducted on particulate respirators that have exhalation valves. To conduct a negative pressure user seal check, cover the filter surface with your hands as much as possible and then inhale. The face piece should collapse on your face and you should not feel air passing between your face and the face piece. 3. Correcting problems discovered during the seal check. In the case of either type of seal check (positive or negative), if air leaks around the nose, use both hands to readjust the nosepiece by placing your fingertips at the top of the metal nose clip. Slide your fingertips down both sides of the metal strip to more efficiently mold the nose area to the shape of your nose. Readjust the straps along the sides of your head until a proper seal is achieved.