Full Text
Updated as of 4/4/2019 Commonly Missed Final Building Inspection Items *NOT INTENDED TO BE A COMPLETE LIST* RESIDENTIAL Exterior: 1. R319.1 House Numbers Installed 2. R401.3 Grade shall fall 6 inches within the first 10 feet away from the structure 3. R806.1 Roof Ventilation Installed 4. E3901.7 GFCI protected outlets with bubble type covers installed front and rear also for decks, porches etc. over 20 sq. ft. 5. R109.1.6 Permanent Power Installed 6. R109.1.6 Sewer Line/Septic Tank approved by proper authority 7. R109.1.6 Handrails, guardrails, steps and decks complete plus code compliant Interior: 1. E Chapter 34 All electrical lights & outlets operation with GFCI & AFCI protection where required 2. R314-315 Smoke alarms/carbon monoxide alarms operation & installed where required 3. P2901 Hot and Cold water Operational 4. R109.1.6 ALL plumbing fixtures installed and operational 5. P2801.7 Water heater seismic bracing, top 1/3 and bottom 1/3 6. R109.1.6 All HVAC systems complete and operational 7. M17-24 Combustion air supplied where required 8. R109.1.6 All handrails, guardrails, and stairs complete and code compliant 9. R310 All egress windows/doors operational and code compliant 10. R302.5 Dwelling/garage fire separation 11. N1101.9 Energy efficiency certificate posted on or in electrical sub panel 12. R408 Crawl space ventilation and vapor retarder installed 13. R408.5 All construction debris removed