Full Text
OTSEGO COUNTY COURT HOUSE / WINDOW AND ROOF REPLACEMENT Gaylord, Michigan CS-001 COVER SHEET SHEET INDEX ARCHITECTURAL GENERAL NO. A-200 EXISTING FIRST FLOOR PLAN LAKE MICHIGAN LAKE SUPERIOR LAKE ERIE LAKE HURON PROJECT LOCATION W. MAIN STREET / M - 32 I - 75 S. OTSEGO AVE. A-202 EXISTING ROOF PLAN A-300 EXISTING EXTERIOR ELEVATIONS / WINDOW SCHEDULE A-201 EXISTING SECOND FLOOR PLAN Sheet Number: Project Number: Sheet Title: Drawn: Checked: Approved: Seal: 45650 Grand River Avenue Novi, Michigan 48374 Ph: (248)349-4500 • Fax: (248)349-1429 Issued For Date THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2019 Project: Client: Corporate Headquarters Lansing • Gaylord • Sault Ste. Marie Key Plan: Novi • Wyandotte • Muskegon www.sidockgroup.com Sidock Group No Scale ARCHITECTS ENGINEERS CONSULTANTS 757 S. Wisconsin Ave. Gaylord, Michigan 49735 Ph: (989)705-8400 • Fax: (989)705-8403 Gaylord Office OTSEGO COUNTY OTSEGO COUNTY COURTHOUSE / WINDOW AND ROOF REPLACEMENT 225 W. MAIN STREET GAYLORD, MI 49735 19099 04/05/19 BID SET CS-001 LB TM BB COVER SHEET A-310 DETAILS CODE DATA BUILDING CODE: MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS - 2015 ALTERATION LEVEL 1 MBC CONSTRUCTION TYPE: VB OCC. GROUP: B (BUSINESS) SITE DATA: ZONING: B-1 (LOCAL BUSINESS) SITE AREA: 1.7 ACRES ENERGY CODE: ASHRAE STANDARD 90.1-2013 W/ 2017 MICHIGAN ENERGY CODE W/ PART 10A AMENDMENTS ---PAGE BREAK--- EXISTING COUNTY BUILDING A A A A A A A A A A A A A A A A A A A A A A A NOTES: · REMOVE AND REPLACE EXISTING WINDOWS WHERE INDICATED. · CONTRACTOR TO REMOVE AND DISPOSE OF EXISTING WINDOWS. · CONTRACTOR TO VERIFY EXISTING ROUGH OPENINGS BEFORE SUBMITTING WINDOW SHOP DRAWINGS. · CONTRACTOR TO COORDINATE WITH OWNER WHEN EACH WINDOW IS TO BE REPLACED - DO NOT START ON AN OPENING UNLESS IT CAN BE REPLACED AND SECURED BY THE END OF THE DAY. · CONTRACTOR TO PATCH AND REPAIR EXISTING CONSTRUCTION AS REQUIRED. · CONTRACTOR MUST VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. A A A A A A Sheet Number: Project Number: Sheet Title: Drawn: Checked: Approved: Seal: 45650 Grand River Avenue Novi, Michigan 48374 Ph: (248)349-4500 • Fax: (248)349-1429 Issued For Date THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2019 Project: Client: Corporate Headquarters Lansing • Gaylord • Sault Ste. Marie Key Plan: Novi • Wyandotte • Muskegon www.sidockgroup.com Sidock Group No Scale ARCHITECTS ENGINEERS CONSULTANTS 757 S. Wisconsin Ave. Gaylord, Michigan 49735 Ph: (989)705-8400 • Fax: (989)705-8403 Gaylord Office OTSEGO COUNTY OTSEGO COUNTY COURTHOUSE / WINDOW AND ROOF REPLACEMENT 225 W. MAIN STREET GAYLORD, MI 49735 19099 04/05/19 BID SET A-200 LB TM BB EXISTING FIRST FLOOR PLAN SCALE: N EXISTING FIRST FLOOR PLAN 1/8"=1'-0" ---PAGE BREAK--- NOTES: · REMOVE AND REPLACE EXISTING WINDOWS WHERE INDICATED. · CONTRACTOR TO REMOVE AND DISPOSE OF EXISTING WINDOWS. · CONTRACTOR TO VERIFY EXISTING ROUGH OPENINGS BEFORE SUBMITTING WINDOW SHOP DRAWINGS. · CONTRACTOR TO COORDINATE WITH OWNER WHEN EACH WINDOW IS TO BE REPLACED - DO NOT START ON AN OPENING UNLESS IT CAN BE REPLACED AND SECURED BY THE END OF THE DAY. · CONTRACTOR TO PATCH AND REPAIR EXISTING CONSTRUCTION AS REQUIRED. · CONTRACTOR MUST VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. EXISTING COUNTY BUILDING EXISTING SHERIFF'S BUILDING A A A A A A A A A A A A A A A A A A Sheet Number: Project Number: Sheet Title: Drawn: Checked: Approved: Seal: 45650 Grand River Avenue Novi, Michigan 48374 Ph: (248)349-4500 • Fax: (248)349-1429 Issued For Date THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2019 Project: Client: Corporate Headquarters Lansing • Gaylord • Sault Ste. Marie Key Plan: Novi • Wyandotte • Muskegon www.sidockgroup.com Sidock Group No Scale ARCHITECTS ENGINEERS CONSULTANTS 757 S. Wisconsin Ave. Gaylord, Michigan 49735 Ph: (989)705-8400 • Fax: (989)705-8403 Gaylord Office OTSEGO COUNTY OTSEGO COUNTY COURTHOUSE / WINDOW AND ROOF REPLACEMENT 225 W. MAIN STREET GAYLORD, MI 49735 19099 04/05/19 BID SET A-201 LB TM BB EXISTING SECOND FLOOR PLAN SCALE: N EXISTING SECOND FLOOR PLAN 1/8"=1'-0" ---PAGE BREAK--- EXISTING COUNTY BUILDING EXISTING SHERIFF'S BUILDING ROOF SYSTEM NOTE: REMOVE EXISTING SHINGLES & FELT PAPER. REPLACE WITH 30 YEAR DIMENSIONAL ASPHALT SHINGLES ON #15 FELT PAPER ON EXISTING SHEATHING. FULLY ADHERED SINGLE PLY MEMBRANE (PVC) ROOF SYSTEM (TAN) ON 1 4" ROOF PROTECTION BOARD ON 1 2" RIGID POLY ISO INSULATION ON EXISTING STRUCTURAL DECK. REFER TO DETAIL 1/A-310. FULLY ADHERED SINGLE PLY MEMBRANE (PVC) ROOF SYSTEM (TAN) ON 1 4" ROOF PROTECTION BOARD ON RIGID POLY ISO INSULATION MIN., R-30) TAPERED ON EXISTING STRUCTURAL DECK. REFER TO DETAIL 2/A-310. REMOVE EXISTING SHINGLES & FELT PAPER ON FIRST FLOOR MANSARD ROOF & CLOCK TOWER. REPLACE WITH 30 YEAR DIMENSIONAL ASPHALT SHINGLES ON #15 FELT PAPER ON EXISTING SHEATHING. ROOF LEGEND - ICE BARRIER MATERIAL, 3 ROWS WIDE LAPPED 6" MINIMUM - MEMBRANE 2A - MEMBRANE 2B ALTERNATE: 1. STANDING SEAM METAL ROOM ON ICE & WATER SHIELD ON ALL MANSARD ROOF AND CLOCK TOWER PER MANUFACTURER INSTALLATION REQUIREMENTS WITH ICE AND WATER SHIELD AND SNOW GUARDS OVER ENTRY DOORS AND WALKWAYS. 1 2A 2B 3 Sheet Number: Project Number: Sheet Title: Drawn: Checked: Approved: Seal: 45650 Grand River Avenue Novi, Michigan 48374 Ph: (248)349-4500 • Fax: (248)349-1429 Issued For Date THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2019 Project: Client: Corporate Headquarters Lansing • Gaylord • Sault Ste. Marie Key Plan: Novi • Wyandotte • Muskegon www.sidockgroup.com Sidock Group No Scale ARCHITECTS ENGINEERS CONSULTANTS 757 S. Wisconsin Ave. Gaylord, Michigan 49735 Ph: (989)705-8400 • Fax: (989)705-8403 Gaylord Office OTSEGO COUNTY OTSEGO COUNTY COURTHOUSE / WINDOW AND ROOF REPLACEMENT 225 W. MAIN STREET GAYLORD, MI 49735 19099 04/05/19 BID SET A-202 LB TM BB EXISTING ROOF PLAN 1 A-310 2 A-310 SCALE: N EXISTING ROOF PLAN 1/8"=1'-0" 2B 1 1 1 1 1 1 1 1 2A 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 SLOPE 1/4" PER FOOT MIN. TYP. SLOPE 1/4" PER FOOT MIN. TYP. SLOPE 1/4" PER FOOT MIN. TYP. 3 3 3 3 3 3 3 3 LINE OF MANSARD ROOF AT FIRST FLOOR BELOW MAIN ROOF LINE OF MANSARD ROOF AT FIRST FLOOR BELOW MAIN ROOF EXISTING MANSARD SLOPE, V.I.F. EXISTING MANSARD SLOPE, V.I.F. EXISTING MANSARD SLOPE, V.I.F. 45° ANGLE, TYP. OUTLINE OF STRUCTURE BELOW TO REMAIN, TYP. L.P. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. EX. L.P. L.P. H.P. L.P. L.P. H.P. SLOPE 1/8" PER FOOT MIN. TYP. EXIST. EXIST. EXIST. EXIST. EXISTING CLOCK TOWER ROOF EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. EXIST. PITCH, V.I.F. PLANTER BOX BELOW REMOVE AND REPLACE EXISTING DRIP EDGE WITH NEW CONTINUOUS PRE-FINISHED METAL DRIP EDGE AT ENTIRE PERIMETER. TYP. U.N.O. 4 A-310 ROOF NOTES 1. INSTALL 1/4" ROOF PROTECTION/ RECOVER BOARD BELOW ALL MEMBRANE ROOFING, TYP. 2. PROVIDE AND INSTALL SOLID WOOD BLOCKING AT ALL TRANSITIONS AND EDGES TO HEIGHT OF ROOF INSULATION, INSTALLED PER ROOF SYSTEM MANUFACTURER. 3. ALL MEMBRANE ROOFING TO BE SLOPED AT 1/4" PER FOOT MINIMUM U.N.O. 4. SADDLES ARE REQUIRED AT ALL LOCATIONS INDICATED OR OTHERWISE NOT INDICATED (I.E. MECHANICAL UNITS, EQUIPMENT CURBS, INSIDE CORNERS AT PARAPET WALLS, ETC.) IN ORDER TO PROVIDE POSITIVE ROOF DRAINAGE. SLOPE ALL SADDLES AT 1/2" PER FOOT MINIMUM U.N.O. 5. DO NOT "BRIDGE" MEMBRANE ROOFING. 6. ALL ROOFTOP PENETRATIONS INCLUDING PLUMBING VENTS, MECHANICAL CURBS, AND ARCHITECTURAL CURBS, SHALL HAVE FLASHING INSTALLED PER ROOF SYSTEM MANUFACTURER. 7. CONTRACTOR TO PROVIDE ALLOWANCE FOR REPLACEMENT OF 15% OF EXIST. ROOF SHEATHING. 8. CONTRACTOR TO PROVIDE ALLOWANCE FOR REPLACEMENT OF 10% OF ROOF FRAMING MEMBERS. 9. ALL ROOF VENTILATION TO COMPLY WITH MBC REQUIREMENTS, "BY OTHER", FIIELD VERIFY EXISTING CONDITIONS AND UPGRADE TO MEET CODE AS REQUIRED. 2A 2A EXIST. EXIST. EXIST. EXIST. 3 EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN REMOVE AND REPLACE EXISTING DRIP EDGE WITH NEW CONTINUOUS PRE-FINISHED METAL DRIP EDGE AT ENTIRE PERIMETER. TYP. U.N.O. REMOVE AND REPLACE EXISTING DRIP EDGE WITH NEW CONTINUOUS PRE-FINISHED METAL DRIP EDGE AT ENTIRE PERIMETER. TYP. U.N.O. REMOVE AND REPLACE EXISTING DRIP EDGE WITH NEW CONTINUOUS PRE-FINISHED METAL DRIP EDGE AT ENTIRE PERIMETER. TYP. U.N.O. 2 A-310 REMOVE AND REPLACE EXISTING DRIP EDGE WITH NEW CONTINUOUS PRE-FINISHED METAL DRIP EDGE AT ENTIRE PERIMETER. TYP. U.N.O. ---PAGE BREAK--- NOTES: · REMOVE AND REPLACE EXISTING WINDOWS WHERE INDICATED. · CONTRACTOR TO REMOVE AND DISPOSE OF EXISTING WINDOWS. · CONTRACTOR TO VERIFY EXISTING ROUGH OPENINGS BEFORE SUBMITTING WINDOW SHOP DRAWINGS. · CONTRACTOR TO COORDINATE WITH OWNER WHEN EACH WINDOW IS TO BE REPLACED - DO NOT START ON AN OPENING UNLESS IT CAN BE REPLACED AND SECURED BY THE END OF THE DAY. · CONTRACTOR TO PATCH AND REPAIR EXISTING CONSTRUCTION AS REQUIRED. · CONTRACTOR MUST VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. A A A A A A A A A A A A A A A A A A A A A NOTE NOTE REMOVE EXISTING WOOD WINDOW SILL AND REPLACE WITH A CEDAR WINDOW SILL TO MATCH EXISTING - PAINT TO MATCH EXISTING - INSTALL SEALANT AROUND ALL EDGES NOTE NOTE 2 A-310 SCALE: PARTIAL EXISTING WEST ELEVATION 1/8"=1'-0" SCALE: EXISTING SOUTH ELEVATION 1/8"=1'-0" 1 3 3 1 A-310 3 A-310 A A A A A A A A OBSCURE GLASS OBSCURE GLASS OBSCURE GLASS OBSCURE GLASS NOTE A A A A A A A A NOTE NOTE SCALE: EXISTING EAST ELEVATION 1/8"=1'-0" SCALE: EXISTING WEST ELEVATION 1/8"=1'-0" 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 A A B B B B B SCALE: EXISTING NORTH ELEVATION 1/8"=1'-0" 3 3 1 1 1 EXISTING CLOCK TOWER TO REMAIN 3 2A 2A 2A 2A 2A 2A 2A 2B 2B NUMBER A WINDOW SCHEDULE TYPE CASEMENT / CLAD FRAME SIZE DETAILS NOTES NOTE: - ACCEPTABLE WINDOW MANUFACTURER'S" ANDERSEN WINDOWS, PELLA WINDOWS OR ARCHITECT APPROVED EQUAL - CONTRACTOR TO FIELD VERIFY ALL OPENINGS TO VERIFY SIZE OF WINDOWS AND OPENINGS BEFORE SUBMITTING SHOP DRAWINGS - EXTERIOR PAINT AND COLOR (SHERWIN WILLIAMS LOXON SELF-CLEANING ACRYLIC COATING LX13: COLOR T.B.D.) - INTERIOR EXPOSED WOOD SHALL BE EITHER PREFINISHED TO MATCH EXIST. STAIN COLOR OR COME UNFINISHED AND BE FIELD STAINED TO MATCH EXIST. STAIN COLOR SUBMITTALS - SHOP DRAWINGS AND PRODUCT DATA - COLOR SAMPLE A or B / A-310 1" INSULATED GLAZING W/ LOW-E AND ARGON GAS x B CASEMENT / CLAD 1" INSULATED GLAZING W/ LOW-E AND ARGON GAS A / A-310 x ROOF SYSTEM NOTE: REMOVE EXISTING SHINGLES & FELT PAPER. REPLACE WITH 30 YEAR DIMENSIONAL ASPHALT SHINGLES ON #15 FELT PAPER ON EXISTING SHEATHING. FULLY ADHERED SINGLE PLY MEMBRANE (PVC) ROOF SYSTEM (TAN) ON 1 4" ROOF PROTECTION BOARD ON 1 2" RIGID POLY ISO INSULATION ON EXISTING STRUCTURAL DECK. REFER TO DETAIL 1/A-310. FULLY ADHERED SINGLE PLY MEMBRANE (PVC) ROOF SYSTEM (TAN) ON 1 4" ROOF PROTECTION BOARD ON RIGID POLY ISO INSULATION MIN., R-30) TAPERED ON EXISTING STRUCTURAL DECK. REFER TO DETAIL 2/A-310. REMOVE EXISTING SHINGLES & FELT PAPER ON FIRST FLOOR MANSARD ROOF & CLOCK TOWER. REPLACE WITH 30 YEAR DIMENSIONAL ASPHALT SHINGLES ON #15 FELT PAPER ON EXISTING SHEATHING. ALTERNATE: 1. STANDING SEAM METAL ROOM ON ICE & WATER SHIELD ON ALL MANSARD ROOF AND CLOCK TOWER PER MANUFACTURER INSTALLATION REQUIREMENTS WITH ICE AND WATER SHIELD AND SNOW GUARDS OVER ENTRY DOORS AND WALKWAYS. 1 2A 2B 3 ADDITIVE: 1. PAINT EXISTING WINDOWS TO MATCH NEW WINDOW COLOR. PAINT EXTERIOR TRIM, STUCCO AND MISCELLANEOUS ARCHITECTURAL ELEMENTS. SHERWIN WILLIAMS LOXON SELF-CLEANING ACRYLIC COATING LX13 (COLOR Sheet Number: Project Number: Sheet Title: Drawn: Checked: Approved: Seal: 45650 Grand River Avenue Novi, Michigan 48374 Ph: (248)349-4500 • Fax: (248)349-1429 Issued For Date THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2019 Project: Client: Corporate Headquarters Lansing • Gaylord • Sault Ste. Marie Key Plan: Novi • Wyandotte • Muskegon www.sidockgroup.com Sidock Group No Scale ARCHITECTS ENGINEERS CONSULTANTS 757 S. Wisconsin Ave. Gaylord, Michigan 49735 Ph: (989)705-8400 • Fax: (989)705-8403 Gaylord Office OTSEGO COUNTY OTSEGO COUNTY COURTHOUSE / WINDOW AND ROOF REPLACEMENT 225 W. MAIN STREET GAYLORD, MI 49735 19099 04/05/19 BID SET A-300 LB TM BB EXISTING EXTERIOR ELEVATIONS, WINDOW SCHEDULE ROOF NOTES 1. INSTALL 1/4" ROOF PROTECTION/ RECOVER BOARD BELOW ALL MEMBRANE ROOFING, TYP. 2. PROVIDE AND INSTALL SOLID WOOD BLOCKING AT ALL TRANSITIONS AND EDGES TO HEIGHT OF ROOF INSULATION, INSTALLED PER ROOF SYSTEM MANUFACTURER. 3. ALL MEMBRANE ROOFING TO BE SLOPED AT 1/4" PER FOOT MINIMUM U.N.O. 4. SADDLES ARE REQUIRED AT ALL LOCATIONS INDICATED OR OTHERWISE NOT INDICATED (I.E. MECHANICAL UNITS, EQUIPMENT CURBS, INSIDE CORNERS AT PARAPET WALLS, ETC.) IN ORDER TO PROVIDE POSITIVE ROOF DRAINAGE. SLOPE ALL SADDLES AT 1/2" PER FOOT MINIMUM U.N.O. 5. DO NOT "BRIDGE" MEMBRANE ROOFING. 6. ALL ROOFTOP PENETRATIONS INCLUDING PLUMBING VENTS, MECHANICAL CURBS, AND ARCHITECTURAL CURBS, SHALL HAVE FLASHING INSTALLED PER ROOF SYSTEM MANUFACTURER. 7. CONTRACTOR TO PROVIDE ALLOWANCE FOR REPLACEMENT OF 15% OF EXIST. ROOF SHEATHING. 8. CONTRACTOR TO PROVIDE ALLOWANCE FOR REPLACEMENT OF 10% OF ROOF FRAMING MEMBERS. 9. ALL ROOF VENTILATION TO COMPLY WITH MBC REQUIREMENTS, "BY OTHER", FIIELD VERIFY EXISTING CONDITIONS AND UPGRADE TO MEET CODE AS REQUIRED. NOTE: CONTRACTOR TO FIELD VERIFY ALL OPENINGS TO VERIFY SIZE OF WINDOWS AND OPENINGS BEFORE SUBMITTING SHOP DRAWINGS NOTE: ALL WINDOWS TO RECEIVE NEW MEMBRANE FLASHING PER WINDOW MANUFACTURE INSTALLATION REQUIREMENTS. ---PAGE BREAK--- JAMB HEAD SILL NEW ALUMINUM COVERED BRICK MOLD HEAD SILL EXISTING STUCCO FINISH SIDING - PATCH AND REPAIR AS REQUIRED DUE TO INSTALLATION OF NEW WINDOW INSTALL SEALANT AROUND PERIMETER OF NEW WINDOW REPLACE EXISTING JAMB TRIM IF REQUIRED FOR INSTALLATION OF NEW WINDOW - WOOD & STAIN TO MATCH EXISTING NEW ALUMINUM COVERED WOOD CASMENT WINDOW NEW ALUMINUM COVERED SILL NOSING EXISTING STUCCO FINISH SIDING - PATCH AND REPAIR AS REQUIRED DUE TO INSTALLATION OF NEW WINDOW INSTALL SEALANT AROUND PERIMETER OF NEW WINDOW REPLACE EXISTING SOLID SURFACE SILL IF REQUIRED FOR INSTALLATION OF NEW WINDOW NEW ALUMINUM COVERED WOOD CASMENT WINDOW NEW ALUMINUM COVERED BRICK MOLD EXISTING BRICK VENEER TO REMAIN INSTALL SEALANT AROUND PERIMETER OF NEW WINDOW REPLACE EXISTING JAMB TRIM IF REQUIRED FOR INSTALLATION OF NEW WINDOW - WOOD & STAIN TO MATCH EXISTING NEW ALUMINUM COVERED WOOD CASMENT WINDOW NEW ALUMINUM COVERED SILL NOSING EXISTING WOOD SILL TO REMAIN - TOUCH-UP PAINT AS REQUIRED FROM CONSTRUCTION ACTIVITIES INSTALL SEALANT AROUND PERIMETER OF NEW WINDOW REPLACE EXISTING SOLID SURFACE SILL IF REQUIRED FOR INSTALLATION OF NEW WINDOW NEW ALUMINUM COVERED WOOD CASMENT WINDOW NEW ALUMINUM COVERED BRICK MOLD INSTALL SEALANT AROUND PERIMETER OF NEW WINDOW NEW ALUMINUM COVERED WOOD CASMENT WINDOW REPLACE EXISTING JAMB TRIM IF REQUIRED FOR INSTALLATION OF NEW WINDOW - WOOD & STAIN TO MATCH EXISTING NEW ALUMINUM COVERED BRICK MOLD EXISTING STUCCO FINISH SIDING - PATCH AND REPAIR AS REQUIRED DUE TO INSTALLATION OF NEW WINDOW INSTALL SEALANT AROUND PERIMETER OF NEW WINDOW NEW ALUMINUM COVERED WOOD CASMENT WINDOW REPLACE EXISTING JAMB TRIM IF REQUIRED FOR INSTALLATION OF NEW WINDOW - WOOD & STAIN TO MATCH EXISTING JAMB Sheet Number: Project Number: Sheet Title: Drawn: Checked: Approved: Seal: 45650 Grand River Avenue Novi, Michigan 48374 Ph: (248)349-4500 • Fax: (248)349-1429 Issued For Date THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2019 Project: Client: Corporate Headquarters Lansing • Gaylord • Sault Ste. Marie Key Plan: Novi • Wyandotte • Muskegon www.sidockgroup.com Sidock Group No Scale ARCHITECTS ENGINEERS CONSULTANTS 757 S. Wisconsin Ave. Gaylord, Michigan 49735 Ph: (989)705-8400 • Fax: (989)705-8403 Gaylord Office OTSEGO COUNTY OTSEGO COUNTY COURTHOUSE / WINDOW AND ROOF REPLACEMENT 225 W. MAIN STREET GAYLORD, MI 49735 19099 04/05/19 BID SET A-310 LB TM BB DETAILS FULLY ADHERED SINGLE PLY MEMBRANE (PVC) ROOF SYSTEM (TAN) ON 1 4" ROOF PROTECTION BOARD ON 1 2" MIN. TAPERED RIGID POLY ISO INSULATION ON EXIST. STRUCTURAL DECK SLOPE 1 8" PER FOOT MIN. EXIST. STRUCTURAL DECK FULLY ADHERED SINGLE PLY MEMBRANE (PVC) ROOF SYSTEM (TAN) ON 1 4" ROOF PROTECTION BOARD ON TAPERED RIGID POLY ISO INSULATION MIN., R-30) ON EXIST. STRUCTURAL DECK SLOPE 1 4" PER FOOT MIN. 12" PRE-FINISHED METAL EDGE FLASHING REMOVE EXISTING SHINGLES AND FELT PAPER. REPLACE WITH 30 YEAR DIMEN. ASPHALT SHINGLES ON #15 FELT PAPER ON EXT. SHEATHING 5" 12 EX. EXISTING SHEATHING EXISITNG STEEL JOIST EXISTING STRUCTURE EXISITNG 2X BLOCKING EXISITNG 1 1 2" RIGID INSULATION SCALE: A-310 3A METAL ROOF DETAIL (ALT.) 3/4"=1'-0" SCALE: A-310 2 MEMBRANE ROOF TRANSITION DETAIL 1 1/2"=1'-0" SCALE: A-310 1 MEMBRANE ROOF TRANSITION DETAIL 1 1/2"=1'-0" REMOVE EXISTING SHINGLES AND FELT PAPER. REPLACE WITH 30 YEAR DIMEN. ASPHALT SHINGLES ON #15 FELT PAPER ON EXT. SHEATHING SCALE: A-310 3 SHINGLE ROOF DETAIL 3/4"=1'-0" EXIST. BUILDING STRUCTURE EXIST. EXT. CLADDING EXISTING FLASHING EXIST. ROOF STRUCTURE EXIST. BUILDING STRUCTURE EXIST. BUILDING STRUCTURE REMOVE EXIST. SHINGLES AND FELT PAPER. REPLACE WITH 30 YEAR DIMEN. ASPHALT SHINGLES ON #15 FELT PAPER ON EXT. SHEATHING REMOVE EXIST. SHINGLES AND FELT PAPER. REPLACE W/ STANDING SEAM METAL ROOF ON ICE & WATER SHIELD ON EXT. SHEATHING SCALE: A-310 B WINDOW DETAILS 1 1/2"=1'-0" SCALE: A-310 A WINDOW DETAILS 1 1/2"=1'-0" 2A PRE-FINISHED METAL EDGE FLASHING 2B FULLY ADHERED SINGLE PLY MEMBRANE (PVC) ROOF SYSTEM (TAN) ON 1 4" ROOF PROTECTION BOARD ON TAPERED RIGID POLY ISO INSULATION ON EXIST. STRUCTURAL DECK SLOPE 1 8" PER FOOT MIN. EXIST. STRUCTURAL DECK SCALE: A-310 4 MEMBRANE ROOF TRANSITION DETAIL 1 1/2"=1'-0" 2B EXIST. EXTERIOR WALL PRE-FINISHED METAL DRIP EDGE 12 EX. 12 EX. EXIST. EXT. CLADDING PRE-FINISHED METAL COUNTER FLASHING EXIST. ROOF STRUCTURE EXIST. BUILDING STRUCTURE PRE-FINISHED METAL DRIP EDGE 12 EX. REGLET W/ SEALANT NEW 2X BLOCKING, MATCH INSULATION HEIGHT LAP MEMBRANE ROOF 1'-0" MIN. DOWN SHEATHING BELOW SHINGLES, VERIFY WITH MANUFACTURER LAP MEMBRANE ROOF 1'-0" MIN. DOWN SHEATHING BELOW SHINGLES, VERIFY WITH MANUFACTURER NOTE: ALL WINDOWS TO RECEIVE NEW MEMBRANE FLASHING PER WINDOW MANUFACTURE INSTALLATION REQUIREMENTS. EXISTING STRUCTURE DECK 8" MIN. METAL FLASHING, REGLET WITH SEALANT TERMINATION BAR WITH SEALANT EXTEND MEMBRANE ROOFING