← Back to Minden

Document Minden_doc_3e3e1742b8

Full Text

www.sunrise-eng.com WASHINGTON, UT 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] JOSEPH PHILLIPS, P.E. PRINCIPAL ENGINEER DATE DATE DATE ENGINEERING TECHNICIAN JOLENE POLISH CHAIRMAN VICE CHAIRMAN BOARD MEMBER BOARD MEMBER TOWN OF MINDEN SEEMAN RANCH PARK PROJECT PRELIMINARY SHEET SET 2021 TOWN MANAGER JD FRISBY BILL DRISCOLL ROXANNE STANGLE STEVE THALER SUSAN JACKSON CITY COUNCIL APPROVALS BOARD MEMBER BRYAN DAVIS September 9, 2021 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] G2 SHEET INDEX ORTH N LOCATION MAP ABBREVIATIONS PROJECT SITE BUCKEYE RD. O R E G O N I D A H O U T A H C A L I F O R N I A A R I Z O N A AREA MAP ORTH N PROJECT LOCATION DOUGLAS COUNTY MAIN ST. 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] G3 TRAFFIC CONTROL NOTES CONSTRUCTION NOTES DESIGN CRITERIA LEGEND A ~ DETAIL - TITLE MATCHLINE SEE DWG XX01 12.31.21 09.09.21 ---PAGE BREAK--- GP1 GP2 GP3 GP4 GP5 DP1, SP1, UP1 DP2, SP2, UP2 ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] G4 ENGINEERING 12.31.21 09.09.21 ---PAGE BREAK--- Buckeye Rd. ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] DP1 ENGINEERING MATCHLINE SEE DWG DP2 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] DP2 ENGINEERING ORTH N MATCHLINE SEE DWG DP1 12.31.21 09.09.21 ---PAGE BREAK--- Buckeye Rd. ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] SP1 ENGINEERING MATCHLINE SEE DWG SP2 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] SP2 ENGINEERING ORTH N MATCHLINE SEE DWG SP1 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] GP1 ENGINEERING ORTH N MATCHLINE SEE DWG GP3 MATCHLINE SEE DWG GP2 12.31.21 09.09.21 ---PAGE BREAK--- Buckeye Rd. www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] GP2 ENGINEERING ORTH N MATCHLINE SEE DWG GP1 MATCHLINE SEE DWG GP3 MATCHLINE SEE DWG GP4 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] GP3 ENGINEERING MATCHLINE SEE DWG GP1 MATCHLINE SEE DWG GP2 MATCHLINE SEE DWG GP5 ORTH N 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] GP4 ENGINEERING MATCHLINE SEE DWG GP5 MATCHLINE SEE DWG GP2 ORTH N 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] GP5 ENGINEERING MATCHLINE SEE DWG GP4 MATCHLINE SEE DWG GP3 ORTH N 12.31.21 09.09.21 ---PAGE BREAK--- Buckeye Rd. Cut/Fill Summary Name Red Blue Volume Surface Totals Cut Factor 1.000 Fill Factor 1.000 2d Area 531242.41 Sq. Ft. 531242.41 Sq. Ft. Cut 312.65 Cu. Yd. 312.65 Cu. Yd. Fill 1932.37 Cu. Yd. 1932.37 Cu. Yd. Net 1619.72 Cu. Yd. 1619.72 Cu. Yd. ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] GP6 ENGINEERING 12.31.21 09.09.21 ---PAGE BREAK--- SEE DWG AP3 MATCHLINE MATCHLINE SEE DWG AP2 AP2 AP3 AP3 AP4 AP5 AP6 ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] AP1 ENGINEERING ALIGNMENT & PROFILE INDEX 12.31.21 09.09.21 ---PAGE BREAK--- SEE DWG AP3 MATC CHLINE SEE DWG AP2 Δ www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] AP2 ENGINEERING ORTH N 12.31.21 09.09.21 ---PAGE BREAK--- SEE DWG AP3 MAT HLINE SEE DWG AP2 Δ www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] AP3 ENGINEERING ORTH N ORTH N 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] AP4 ENGINEERING ORTH N 12.31.21 09.09.21 ---PAGE BREAK--- Δ www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] AP5 ENGINEERING ORTH N 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] AP6 ENGINEERING ORTH N 12.31.21 09.09.21 ---PAGE BREAK--- Buckeye Rd. ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] UP1 ENGINEERING MATCHLINE SEE DWG UP2 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] UP2 ENGINEERING ORTH N MATCHLINE SEE DWG UP1 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] D1 ENGINEERING A ~ DETAIL - GRAVEL PAVEMENT B ~ SECTION - ASPHALT CONCRETE C ~ DETAIL - TYPICAL TRAIL CROSS SECTION D ~ DETAIL - WATER FEATURE CROSS SECTIONS 12.31.21 09.09.21 ---PAGE BREAK--- D ~ DETAIL - STABILIZED CONSTRUCTION ENTRANCE www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] D2 ENGINEERING E TYP DETAIL - ACCESSIBLE PARKING VAN VAN/CAR VAN ACCESSIBLE ACCESSIBLE PARKING F TYP DETAIL - ACCESSIBLE PARKING SIGN G TYP DETAIL - PAVILION CONCRETE SLAB H TYP DETAIL - WATER FOUNTAIN STATION B TYP DETAIL - CONCRETE SLAB A TYP DETAIL - CONCRETE PAVILION SLAB C TYP DETAIL - FISH SCREEN/GATE 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] D3 ENGINEERING FRONT VIEW 4 RIGHT SIDE VIEW TOP VIEW 2 1 3 FRONT VIEW 4 2 1 TOP VIEW 3 BOTTOM VIEW MOUNTING DETAIL 4 5 A ~ DETAIL - PARK BENCH B ~ DETAIL - TRASH RECEPTACLE C TYP PLAN VIEW - BENCH SLAB D TYP DETAIL - PICNIC TABLE E TYP DETAIL - PEDESTAL GRILL F TYP DETAIL - FROST FREE HYDRANT 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] D4 ENGINEERING A TYP DETAIL - MOW CURB & FENCE CURB 12" FENCE CURB 6" MOW CURB B TYP DETAIL - RIPRAP LINED DITCH C TYP DETAIL - RAILROAD TIE WHEELSTOP D TYP CONCEPT - FLOATING DOCK E ~ DETAIL - CONCRETE STAIRS F ~ DETAIL - STAIR HANDRAIL G ~ DETAIL - ABRASIVE NOSING 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] D5 ENGINEERING A TYP DETAIL - CHAINLINK FENCE KNUCKLED TOP AND BOTTOM SELVAGE BOTTOM GATE HINGE AND GATE DETAILS TYPICAL TIE DETAILS TOP GATE HINGE BRACE AND TRUSS CONNECTIONS 12.31.21 09.09.21 ---PAGE BREAK--- D6 ---PAGE BREAK--- D7 ---PAGE BREAK--- D8 ---PAGE BREAK--- D9 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] D10 ENGINEERING ---PAGE BREAK--- Buckeye Rd. Buckeye Rd. ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP1 ENGINEERING OVERALL LANDSCAPE PLAN Scale: 1"=50'-0" LANDSCAPE & IRRIGATION PLAN SHEETS Page Sheet Plan Description 1 Overall Landscape Plan LP1 2 LP2 3 LP3 4 Planting Plan - Area B LP4 5 LP5 6 7 LP8 8 9 Landscape Materials & Plant List 10 Planting Plan Details & Notes LP9 Planting Plan - Area C Irrigation Plan - Area C Irrigation Plan Details LP10 Irrigation Plan Notes Planting Plan - Area A Irrigation Plan - Areas A & B LP6 LP7 AREA B AREA A AREA C Trees LANDSCAPE MATERIALS & PLANT LIST Scientific Name Common Name Symbol Shrubs Grasses Annuals/Perennials Other Materials Know what'sbelow. before you dig. Call R 12.31.21 09.09.21 ---PAGE BREAK--- ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP2 ENGINEERING PLANTING PLAN - AREA A Scale: 1"=10'-0" EXISTING PARKING & LANDSCAPING EXISTING PARKING & LANDSCAPING Know what'sbelow. before you dig. Call R MATCH LINE SEE SHEET LP3 MATCH LINE SEE SHEET LP3 Buckeye Rd. 12.31.21 09.09.21 ---PAGE BREAK--- ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP3 ENGINEERING WATER FEATURE Scale: 1"=10'-0" Know what'sbelow. before you dig. Call R MATCH LINE SEE SHEET LP2 MATCH LINE - SEE SHEET LP4 Buckeye Rd. PLANTING PLAN - AREA B Scale: 1"=10'-0" 12.31.21 09.09.21 ---PAGE BREAK--- ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP4 ENGINEERING PLANTING PLAN - AREA C Scale: 1"=10'-0" Know what'sbelow. before you dig. Call R MATCH LINE - SEE SHEET LP4 DOG PARK 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP5 ENGINEERING MULTI-STEM TREE PLANTING Not to Scale ™TREE TIE ™ ™ TREE TIE TAPER DOWN DEPTH OF MULCH AT CROWN OF PLANT SCARIFY SIDES OF PLANTING HOLE 2 X CONTAINER DIAMETER INSTALL ROOT BALL EVEN WITH FINISH GRADE AND KEEP MULCH AWAY FROM BASE OF PLANT CONSTRUCT 2-3" TALL WATERING RING AROUND EDGE OF PLANTING PIT NOTE: EXCAVATE PLANTING PITS AS ROUND PLANTING HOLES EXISTING SUBGRADE PLANTING SOIL WEED BARRIER FABRIC MULCH TREE PLANTING & STAKING DETAIL Not to Scale SHRUB PLANTING DETAIL Not to Scale LANDSCAPE NOTES: MAINTENANCE & GUARANTEE: GENERAL CONSTRUCTION NOTES: Know what'sbelow. before you dig. Call R TAPER DOWN DEPTH OF MULCH AT CROWN OF PLANT SCARIFY SIDES OF PLANTING HOLE INSTALL ROOT BALL EVEN WITH FINISH GRADE AND KEEP MULCH AWAY FROM BASE OF PLANT CONSTRUCT 2-3" TALL WATERING RING AROUND EDGE OF PLANTING PIT NOTE: EXCAVATE PLANTING PITS AS ROUND PLANTING HOLES EXISTING SUBGRADE PLANTING SOIL MULCH 2 X CONTAINER DIAMETER EXISTING SUBGRADE MULCH AS PER PLAN BOULDER BURY 1/3 OF BOULDER BOULDER INSTALLATION DETAIL Not to Scale GRASS PLANTING DETAIL Not to Scale 12.31.21 09.09.21 ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP6 ENGINEERING Know what'sbelow. before you dig. Call R Trees LANDSCAPE MATERIALS & PLANT LIST Scientific Name Common Name Symbol Qty Notes Size Shrubs Grasses Annuals/Perennials Other Materials 12.31.21 09.09.21 ---PAGE BREAK--- Buckeye Rd. Buckeye Rd. ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP7 ENGINEERING IRRIGATION PLAN - AREAS A & B Scale: 1"=20'-0" EXISTING PARKING & LANDSCAPING RAIN BIRD CONTROL ZONE KIT, MODEL NO. XCZ-100-PRB-COM (OR APPROVED EQUAL). APPROVED BALL VALVE, LINE SIZE SIGNATURE 1" QUICK COUPLER APPROVED MANUAL DRAIN VALVE. INSTALLED AT LOW POINT OF MAIN & DRIP LINES. APPROVED NEW 1" SCH 40 PVC MAINLINE APPROVED NEW 4" SCH 40 PVC SLEEVE. TORO NEW 1" BLUE STRIPE HOSE (OR APPROVED EQUAL). 2. 1/4" VINYL DISTRIBUTION TUBING: RAIN BIRD DT - 025 (OR APPROVED EQUAL) REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT. 1. SYSTEM DESIGN IS BASED ON MAX. FLOW OF 12 G.P.M. WITH 50 P.S.I. AT IRRIGATION CONTROL VALVES CONTRACTOR SHALL VERIFY FLOW RATES AND PRESSURE AND NOTES: EXISTING EXISTING 1" RPZ BACKFLOW DEVICE w/ BLOW OUT FLUSH FITTING RAIN BIRD EXISTING WATER METER AS PER CITY STANDARDS. NOT SHOWN (SEE DETAILS). APPROVED NEW 1" SCH 40 PVC LATERAL LINE IRRIGATION LEGEND EXISTING EXISTING RAINBIRD TBOS2-CMI &TBOS2-FTUS: 1 STATION BATTERY OPERATED IRRIGATION CONTROLLER w/ FIELD TRANSMITTER. EXISTING EXISTING LINE SIZE STOP & WASTE VALVE EXISTING EXISTING CONTROL ZONE KIT, MODEL NO. XCZ-100-PRB-COM EXISTING EXISTING 1" SCH 40 PVC MAINLINE RAIN BIRD RAINBIRD PEB SERIES VALVE (OR APPROVED EQUAL). RAIN BIRD RAIN BIRD RAIN BIRD 5004-PC-SAM-R ROTOR w/4.0 NOZZLE (OR APPROVED EQUAL). 5004-PC-SAM-R ROTOR w/2.0 NOZZLE (OR APPROVED EQUAL). 5004-PC-SAM-R ROTOR w/1.5 NOZZLE (OR APPROVED EQUAL). DRIP ZONE & FLOW CHART TURF ZONE & FLOW CHART NEW RAINBIRD TBOS-BT1 & TBOS-BT4: 1 & 4 STATION BATTERY OPERATED IRRIGATION CONTROLLER w/ FIELD TRANSMITTER. SEE PLAN FOR SIZE. Know what'sbelow. before you dig. Call R MATCH LINE - SEE SHEET LP8 12.31.21 09.09.21 ---PAGE BREAK--- ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP8 ENGINEERING IRRIGATION PLAN - AREA C Scale: 1"=20'-0" RAIN BIRD CONTROL ZONE KIT, MODEL NO. XCZ-100-PRB-COM (OR APPROVED EQUAL). APPROVED BALL VALVE, LINE SIZE SIGNATURE 1" QUICK COUPLER APPROVED MANUAL DRAIN VALVE. INSTALLED AT LOW POINT OF MAIN & DRIP LINES. APPROVED NEW 1" SCH 40 PVC MAINLINE APPROVED NEW 4" SCH 40 PVC SLEEVE. TORO NEW 1" BLUE STRIPE HOSE (OR APPROVED EQUAL). 2. 1/4" VINYL DISTRIBUTION TUBING: RAIN BIRD DT - 025 (OR APPROVED EQUAL) REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT. 1. SYSTEM DESIGN IS BASED ON MAX. FLOW OF 12 G.P.M. WITH 50 P.S.I. AT IRRIGATION CONTROL VALVES CONTRACTOR SHALL VERIFY FLOW RATES AND PRESSURE AND NOTES: EXISTING EXISTING 1" RPZ BACKFLOW DEVICE w/ BLOW OUT FLUSH FITTING RAIN BIRD EXISTING WATER METER AS PER CITY STANDARDS. NOT SHOWN (SEE DETAILS). APPROVED NEW 1" SCH 40 PVC LATERAL LINE IRRIGATION LEGEND EXISTING EXISTING RAINBIRD TBOS2-CMI & TBOS2-FTUS: 1 STATION BATTERY OPERATED IRRIGATION CONTROLLER w/ FIELD TRANSMITTER. EXISTING EXISTING LINE SIZE STOP & WASTE VALVE EXISTING EXISTING CONTROL ZONE KIT, MODEL NO. XCZ-100-PRB-COM EXISTING EXISTING 1" SCH 40 PVC MAINLINE RAIN BIRD RAINBIRD PEB SERIES VALVE (OR APPROVED EQUAL). RAIN BIRD RAIN BIRD RAIN BIRD 5004-PC-SAM-R ROTOR w/4.0 NOZZLE (OR APPROVED EQUAL). 5004-PC-SAM-R ROTOR w/2.0 NOZZLE (OR APPROVED EQUAL). 5004-PC-SAM-R ROTOR w/1.5 NOZZLE (OR APPROVED EQUAL). DRIP ZONE & FLOW CHART TURF ZONE & FLOW CHART DOG PARK NEW RAINBIRD TBOS-BT1 & TBOS-BT4: 1 & 4 STATION BATTERY OPERATED IRRIGATION CONTROLLER w/ FIELD TRANSMITTER. SEE PLAN FOR SIZE. Know what'sbelow. before you dig. Call R MATCH LINE - SEE SHEET LP7 12.31.21 09.09.21 ---PAGE BREAK--- DIFFUSER BUG CAP 1/4 INCH TUBING STAKE FINISH GRADE 1/4 INCH PE DISTRIBUTION TUBING SINGLE OUTLET EMITTER PE DISTRIBUTION TUBING FINISH GRADE SHRUB STAKE DIFFUSER BUG CAP AT EDGE OF ROOTBALL POINT SOURCE EMITTER SYSTEM REFER TO ENLARGEMENT PE DISTRIBUTION TUBING 18" 24" SEE NOTE #2 PLAN VIEW FINISH GRADE SIDEWALK OR CURB BASE COURSE LATERAL LINE TRENCH BACKFILL MATERIAL EXISTING SUB-GRADE DETECTABLE WARNING TAPE - MAINLINE (TYP.) MAINLINE CONTROLLER WIRES. BUNDLE AND TAPE TOGETHER EVERY 20' NOTE: 1. TIE A LOOSE 24" LOOP IN ALL WIRING AT CHANGES OF DIRECTION GREATER THAN 30 DEGREES. UNTIE LOOPS AFTER ALL CONNECTIONS HAVE BEEN MADE. 2. MAINLINE AND LATERAL LINES TO BE PLACED NO MORE THAN 12" FROM BACK OF SIDEWALK OR CURB IN PARK STRIPS AND MEDIANS. 6" ASPHALT OR CONCRETE PAVING BASE COURSE COMPACTED SUBGRADE DETECTABLE WARNING TAPE (TYP.) SURROUND SLEEVES WITH 2" OF SAND IN ALL DIRECTIONS NOTE: 1. WHEN MULTIPLE PIPES OCCUR IN ONE TRENCH ADD MULTIPLE SLEEVES. 2. WIRES SHALL BE IN SEPARATE SLEEVE. SEPARATE SCHEDULE 40 SLEEVE FOR: CONTROLLER WIRES - 4" MIN. SIZE LATERAL LINES - 4" MIN. SIZE MAINLINE - 4" OR 6" SIZE 12" MIN. ROUND TAN PLASTIC VALVE BOX WITH LOCKING COVER LABELED WITH 3" HT. HEAT BRANDED LETTERS - " QC " 3/4" SIZE BRASS NIPPLE (LENGTH AS REQUIRED) 6" MINIMUM DEPTH OF 3/4" WASHED ANGULAR GRAVEL FINISH GRADE, LID 1" ABOVE SIDEWALK, CURB, WALL, ETC. PVC SCH 40 STREET ELL BRICK STABILIZER PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) PVC SCH 40 STREET ELL PVC SCH 40 TEE OR ELL PVC MAINLINE PIPE PVC SCH 40 ELL NOTE: 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. VALVE BOX COVER COLOR: TAN FINISH GRADE, LID 1" ABOVE 1" BALL VALVE WITH STAINLESS STEEL GEAR CLAMP OR PVC CONNECTION PE DISTRIBUTION TUBE OR PVC MAINLINE BRICK SUPPORT 3/4" ANGULAR GRAVEL SUMP 12" X12" VALVE BOX COVER COLOR: TAN FINISH GRADE, LID 1" ABOVE FINISH GRADE GATE VALVE, LINE SIZE PVC MAINLINE BRICK SUPPORT 3/4" ANGULAR GRAVEL SUMP 12" X12" ADJACENT CONCRETE SIDEWALK/CURB FINISH GRADE ROTOR POP-UP SPRINKLER PVC SCH. 80 NIPPLE (LENGTH AS REQUIRED) PVC SCH. 40 ELL MARLEX STREET ELL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) MARLEX STREET ELL PVC SCH 40 TEE OR ELL PVC LATERAL PIPE 18" MIN. 3" MIN. 3" MIN. PVC MAINLINE AND GATE VALVE BEYOND FINISH GRADE; LID 1" ABOVE VALVE BOX WITH COVER. COLOR:TAN 30-INCH LINEAR LENGTH OF WIRE, COILED WATERPROOF CONNECTORS ID TAG: CHRISTIE TAG WITH VALVE NUMBER, PURPLE (RECLAIMED) OR YELLOW (CULINARY) FINISH GRADE REMOTE CONTROL VALVE PER IRRIGATION PLAN LEGEND SCH 80 ACTION UNION (2 TYP.) PVC LATERAL PIPE PVC SCH 40 ELL 6" MINIMUM DEPTH OF 3/4" WASHED ANGULAR GRAVEL STABILIZING BRICK (TYP.) PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) VALVE MANIFOLD NOTE: GROUP VALVES TOGETHER & PROVIDE ONE GATE VALVE, LINE SIZE PER GROUP 1" QUICK COUPLER (WHERE INDICATED) REMOTE CONTROL VALVE GATE VALVE MAINLINE CONTROL MODULE RAIN BIRD TBOS RAIN SHUT-OFF DEVICE RAIN BIRD TBOS WATERPROOF CONNECTION (TYPICAL) RAIN BIRD TBOS SOLENOID (TYPICAL) REMOTE CONTROL VALVE (TYPICAL) TBOS TM A B C 1 2 34C 1 5 4 2 3 Rain Bird PRS-Dial Pressure regulator 9V DC latching solenoid 2 x 1.5 mm² cable Rain Bird waterproof wire connector Manual valve 2 1 3 4 5 1 4 2 3 Pressure-regulating filter Rain Bird PRF-075-RBY 9V DC latching solenoid Rain Bird waterproof wire connector Manual valve 1 2 3 4 ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP9 ENGINEERING Not to Scale XCZ-PRB-150-COM 1.5" COMMERCIAL CONTROL ZONE KIT IN A SQUARE VALVE BOX, STRAIGHT CONFIGURATION Not to Scale QUICK COUPLER Not to Scale SLEEVE SECTION Not to Scale IRRIGATION TRENCH SECTION Not to Scale GATE VALVE Not to Scale MANUAL DRAIN VALVE Not to Scale THREE PROGRAM BATTERY-OPERATED CONTROLLER Not to Scale SHRUB EMITTER LAYOUT Not to Scale REMOTE CONTROL IRRIGATION VALVE Not to Scale RAINBIRD 5000 ROTOR SPRINKLER Not to Scale RAINBIRD XCZ-075-PFR START-UP KIT+TBOS-II Not to Scale PEB VALVE+PRS-DIAL+TBOS-II RAINBIRD TBOS WIRING DIAGRAM Know what'sbelow. before you dig. Call R 12.31.21 09.09.21 ---PAGE BREAK--- ORTH N www.sunrise-eng.com WASHINGTON, UTAH 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] LP10 ENGINEERING IRRIGATION NOTES: GENERAL CONSTRUCTION NOTES: MAINTENANCE AND GUARANTEE: Know what'sbelow. before you dig. Call R 12.31.21 09.09.21 ---PAGE BREAK--- GENERAL NOTES 1. CONSULT ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL LIGHTING FIXTURES. 2. VERIFY ALL EQUIPMENT DIMENSIONS AND LOCATIONS BEFORE BEGINNING ROUGH IN. CONSULT ALL APPLICABLE CONTRACT DRAWINGS AND SHOP DRAWINGS TO INSURE NEC CODE CLEARANCES REQUIRED AROUND ALL ELECTRICAL EQUIPMENT. 3. CONTRACTOR SHALL VERIFY ALL ELECTRICAL LOADS (VOLTAGE, PHASE, CONNECTION REQUIREMENTS, ETC.) OF ALL EQUIPMENT FURNISHED UNDER ALL DIVISIONS, INCLUDING ALL EXISTING EQUIPMENT TO BE RE-USED. REVIEW ALL SHOP DRAWINGS AND EXISTING EQUIPMENT BEFORE BEGINNING ROUGH IN. 4. SEE SECTION 265100 (16510) OF THE SPECIFICATION REQUIRED COORDINATION MEETINGS WITH MECHANICAL AND CEILING CONTRACTORS. 5. SEE APPLICABLE SHOP DRAWINGS FOR ROUGH IN LOCATION OF ALL EQUIPMENT, WIRING DEVICES, ETC. WHERE APPLICABLE MOUNT ALL WIRING DEVICES ABOVE BACK SPLASH EXCEPT THOSE SERVING UNDER COUNTER EQUIPMENT. 6. SEE SPECIFICATION FOR ENERGY SAVING LAMP AND BALLAST REQUIREMENTS. 7. FINISHES OF ALL LIGHT FIXTURES SHALL BE AS SELECTED BY ARCHITECT. 8. THE ELECTRICAL CONTRACTOR SHALL NOTIFY AND COOPERATE WITH THE MECHANICAL CONTRACTOR SUCH THAT NO PIPING, DUCTS, OR EQUIPMENT FOREIGN TO THE OPERATION OF THE ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE INSTALLED IN, ENTER OR PASS THRU ELECTRICAL ROOMS OR SPACES, OR ABOVE OR BELOW ELECTRICAL EQUIPMENT IN OTHER AREAS. 9. ELECTRICAL BOXES SHALL NOT BE LOCATED IN MASONRY COLUMNS IN BRICK WALLS OR IN GROUTED CELLS ADJACENT TO OPENINGS. COORDINATE LOCATION OF BOXES WITH MASONRY CONTRACTOR. 10. ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS, AND CEILINGS SHALL BE SEALED WITH APPROVED MATERIAL TO MAINTAIN FIRE RATING OF SURFACE PENETRATED. 11. CONTRACTOR SHALL VERIFY FURNITURE LAYOUT PRIOR TO ANY FLOORBOX OR POKE-THRU INSTALLATION. COORDINATE EXACT LOCATION OF FLOOR BOX OR POKE-THRU WITH OWNER AND FURNITURE PROVIDER PRIOR TO ROUGH-IN. 12. CIRCUITS EXTENDING OVER 70' FOR 120 VOLT AND 115' FOR 277 VOLT 20 AMP CIRCUITS SHALL BE RUN WITH CONDUCTORS PER TABLE BELOW. A. THESE ARE BASED ON MAXIMUM LENGTH OF CIRCUIT. B. PERFORM VOLTAGE DROP CALCULATIONS AND PROVIDE CONDUCTOR SIZE TO KEEP BRANCH CIRCUIT VOLTAGE DROP LESS THAN 3% WITH A 15 AMP LOAD. C. CONTRACTOR SHALL ENSURE THAT THE INSTALLATION OF EACH BRANCH CIRCUIT STAYS WITHIN 3% VOLTAGE DROP FOR A 15 AMP LOAD. IF NECESSARY, CONTRACTOR SHALL INCREASE WIRE AND CONDUIT SIZE TO MEET THE STANDARD AT NO ADDITIONAL COST TO OWNER. MAXIMUM LENGTH <70 MIN. #12 AWG 70 - 115 115 - 170 170 - 270 20 AMP MINIMUM BRANCH CIRCUIT CONDUCTOR SIZING BRANCH CIRCUIT VOLTAGE CONDUCTOR LENGTH (FT) 120 VOLT 277 VOLT 271 - 380 >380 MIN. #12 AWG MIN. #10 AWG MIN. #12 AWG MIN. #8 AWG MIN. #10 AWG MIN. #6 AWG MIN. #8 AWG NOTE B MIN. #8 AWG NOTE B NOTE B ONE CIRCUIT, HOME RUN TO PANEL CONDUIT RUN CONCEALED IN FLOOR OR GROUND DUPLEX RECEPTACLE 9. 11. AS NOTED +16" OR WEATHERPROOF RECEPTACLE WP 2. 9. AS NOTED +24" OR POWER POLE JUNCTION BOX IN FLOOR) J AS NOTED PANEL BOARD TOP AT LIGHT FIXTURE (LETTER DESIGNATES TYPE) A STANDARD MOUNTING HEIGHT UNLESS OTHERWISE NOTED ON PLANS SYMBOL DESCRIPTION MOUNTING HEIGHT NOTES FLOOD OR TRACK FIXTURE AS NOTED TIMER SWITCH 6. STM LIGHT FIXTURE AS NOTED 1 LIGHT FIXTURE GENERAL NOTES REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF LIGHT FIXTURES. BRING ALL DISCREPANCIES OF LOCATIONS AND QUANTITIES TO THE ATTENTION OF THE ARCHITECT AND ELECTRICAL ENGINEER PRIOR TO BIDDING. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS AND LOCATIONS OF LIGHT FIXTURES. BRING ALL DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING. REFER TO THE SPECIFICATIONS FOR OTHER LIGHT FIXTURE, FUSING, BALLAST, AND LAMP REQUIREMENTS AND ACCEPTABLE MANUFACTURERS. CONFIRM AVAILABLE MOUNTING DEPTHS OF ALL LIGHT FIXTURES AND COMPARE WITH DEPTHS SHOWN ON SHOP DRAWINGS. BRING ALL POTENTIAL CONFLICT AREAS TO THE ATTENTION OF THE ARCHITECT AND ELECTRICAL ENGINEER PRIOR TO RELEASE. REFER TO LIGHTING PLANS FOR ALL LINEAR FIXTURE THE CATALOG NUMBER IS BASED ON THE FIXTURE SPECIFIED AND MAY NOT REFLECT THE QUANTITY OR OVERALL LENGTH OF LINEAR FIXTURES REQUIRED. CONTRACTOR TO NOTE THAT VARIOUS FIXTURE MAY BE REQUIRED TO ACHIEVE THE OVERALL RUN LENGTH. REFER TO LIGHTING PLANS FOR ALL UNDERCABINET FIXTURE THE CATALOG NUMBER IS BASED ON THE FIXTURE SPECIFIED AND MAY NOT REFLECT THE QUANTITY OR OVERALL LENGTH OF UNDERCABINET FIXTURES REQUIRED. CONTRACTOR TO NOTE THAT VARIOUS FIXTURE MAY BE REQUIRED TO ACHIEVE THE OVERALL RUN LENGTH OR TO FIT WITHIN THE MILLWORK. COORDINATE FIXTURE LAYOUT WITH MILLWORK SHOP DRAWINGS PRIOR TO LIGHTING SUBMITTALS. WHEN A CONTRADICTION EXISTS BETWEEN A SPECIFIC MODEL NUMBER AND THE DESCRIPTION, THE DESCRIPTION SHALL GOVERN. PRIOR APPROVALS SHALL BE SUBMITTED TO THE ELECTRICAL ENGINEER'S OFFICE AT LEAST EIGHT WORKING DAYS BEFORE THE BID. PRIOR APPROVALS RECEIVED AFTER THIS TIME PERIOD SHALL BE REJECTED. REFER TO SPECIFICATIONS 260500, 265100 & 265600 (16001, 16510 & 16551). VALUE ENGINEERING CONDUCTED WITHOUT THE DESIGN TEAM IE; ARCHITECT, OWNER, ENGINEER & LIGHTING CONSULTANT/DESIGNER WILL NOT BE ALLOWED, REVIEWED OR APPROVED. SFBA CFBA WALL@CLG CCBA SCBA A.F.F. STANDARD FINISH AS SELECTED BY THE ARCHITECT CUSTOM FINISH AS SELECTED BY THE ARCHITECT STANDARD PAINTED COLOR AS SELECTED BY THE ARCHITECT CUSTOM PAINTED COLOR AS SELECTED BY THE ARCHITECT WALL MOUNT AT CORNER OF WALL AND CEILING ABOVE FINISH FLOOR 5. 3. 4. 2. LIGHT FIXTURE ABBREVIATION SCHEDULE 1. 6. 8. 7. 9. 10. LIGHT FIXTURE SCHEDULE NOTES www.sunrise-eng.com WASHINGTON, UT 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] ENGINEERING 635 South State Street Salt Lake City, Utah 84111 P:[PHONE REDACTED] F:[PHONE REDACTED] www.bnaconsulting.com BNA CONSULTING SALT LAKE ST.GEORGE ---PAGE BREAK--- ELECTRICAL SPECIFICATIONS 1. a. DIVISION 26 - ELECTRICAL Electrical General Provisions: Description of Work: Extent of electrical work is indicated on drawings. Provide all labor, materials, equipment, supervision and service necessary for a complete electrical system. Work includes, but is not necessarily limited to the following items: a. Electrical Connections for Equipment i. b. Grounding j. Panelboards and Switchboards c. Conduit Raceway k. d. Conductors and Cables l. Overcurrent Protective Devices e. Electrical Boxes and Fittings f. Supporting Devices Light Fixtures g. Electrical Seismic Control Electrical Identification h. Wiring Devices b. Visit the site during the bidding period to determine existing conditions affecting electrical and other work. All costs arising from site conditions and/or preparation shall be included in the base bid. No additional charges will be allowed due to inadequate site inspection. c. Quality Assurance: Perform work in accordance with the National Electrical Code (NEC). Comply with requirements of State and Local Ordinances. Obtain all permits, inspections, etc. from Authority Having Jurisdiction (AHJ). Employ only qualified craftsmen with at least three years of experience. Workmanship shall be neat, have a good mechanical appearance and conform to best electrical state contracting license. Provide equipment and material that are Underwriters Laboratories Inc. (UL) listed and labeled. 1. Submittals: After the Contract is awarded but prior to manufacture or installation of any equipment, prepare complete shop drawings. 2. ELECTRONIC SUBMITTAL REQUIREMENTS: a. Provide submittals in Portable Document Format (PDF). b. Documents must be electronically bookmarked and keyword searchable using Adobe Acrobat (http://www.adobe.com/acrobat) or Bluebeam Revu (http://www.bluebeam.com) for each relevant section. Include electronic bookmarks separating “Light Fixtures” from “Panelboards”. c. Electronically highlight all options for light fixtures, electrical equipment, etc. Manual highlighting and scanning of the documents is NOT acceptable and will NOT be reviewed. d. Provide only completed cutsheets for all fixture and equipment types. Blank cutsheets submitted with a schedule are NOT acceptable and will NOT be reviewed. e. A maximum of one submittal per specification section is allowed. It is NOT acceptable to provide a product by product submittal. Single product by product submittals will NOT be reviewed. Wiring Devices Panelboards and Switchboards Light Fixtures Overcurrent Protective Devices d. Record Drawings: Maintain on a daily basis, a complete set of record drawings, reflecting an accurate dimensional record of all buried or concealed work. Mark record drawings to show the precise location of concealed work and equipment, including concealed or embedded conduit and junction boxes and all changes and deviations in the work from that shown on the Contract Documents. e. Operation and Maintenance Manuals: Provide operating instruction and maintenance data books for all equipment and materials furnished under this division. f. Guarantee: Ensure that electrical systems installed under this contract is in proper wiring order and in compliance with drawings, specifications, and/or authorized changes. Without additional charge, replace any work or materials which develop defects, except form ordinary wear and tear, within one year from the date of substantial completion. g. Fire Protection Seals: Seal all penetrations for work of this section through fire rated floors, walls, and ceilings to prevent the spread of smoke, fire, toxic gas, or water through the penetration either before, during and after fire. h. Power Outages: All power outages required for execution of this work shall occur during the non-standard working hours and at the convenience of the owner. Include all costs for overtime work in bid. 2. Electrical Connections for Equipment: Verify exact load and location of all equipment before rough-in for each electrical connection. Provide complete assembly of material, including but not necessarily limited to, raceways, conductors, cords, cord caps, plugs, wiring devices, pressure connectors, terminals (lugs), electrical insulating tape, heat-shrinkable insulating tubing, cable ties, solderless wire nuts, and other items and accessories as needed to complete splices, terminations, and connections as required. For permanently installed fixed equipment, provide flexible seal-tite connection. For movable and/or portable equipment, provide wiring device, cord cap, and multi-conductor cord. 3. Grounding: Provide grounding and bonding of all electrical and communication apparatus, machinery, appliances, building components, and items required by the NEC to provide a permanent, continuous low impedance, grounding system. Provide an NEC bonding/grounding conductor in all raceways used for power distribution. 4. Conduit Raceways: Provide metal conduit, tubing, and fittings of types, grades, sizes, and weights (wall thickness) as required; with minimum trade size of 3/4". Install electrical raceway systems in accordance with manufacturer ’s written instructions and applicable requirements of NEC and NECA “Standard of Installation” in accordance with the following: a. Feeders: Install feeders rated 100 Amps and greater, in Electrical Mettalic conduit (EMT); Where buried below grade, install in concrete encased non-metallic conduit or duct (Schedule 40 PVC). b. Branch Circuits, and individual Equipment Circuits rated less than 100 Amps: Install in Electrical Metallic Tubing (EMT). Where located in poured walls, below concrete slab-on-grade, or in earth fill, install in non-metallic plastic duct (Schedule 40 PVC). Encase non-metallic plastic duct1-1/4" and larger in concrete. c. Provide rigid metal conduit (RMC) for all bends in buried conduit greater than 30 degrees. Provide protective coating for rigid metal conduit bends. Install flexible conduit for connections of motors, transformers, and other electrical equipment where subject to movement and vibrations. Provide OZ, expansion fittings on all conduits crossing building expansion joints, both in slab and suspended. d. Provide surface raceways of sizes and channels indicated. Provide fittings that match and mate with raceway. 5. Conductors and Cables: Provide factory-fabricated conductors for sized, ratings, material, and types indicated for each service. Provide copper conductors, with THHN/THWN insulation. Size all conductors in accordance with NEC; minimum size to be #12 AWG. Provide stranded conductors for #8 AWG and larger. 6. Electrical Boxes and Fittings: Provide one piece galvanized flat rolled sheet steel interior outlet wiring boxes, corrosion-resistant cast-metal weatherproof outlet wiring boxes, code-gage sheet steel junctions and pull boxes, cast-iron waterproof adjustable floor boxes, galvanized cast- metal conduit bodies, corrosion-resistant punched-steel box knockout closures, conduit lockouts and malleable steel conduit bushings and offset connectors, and all accessories as required to suit each respective location and installation. Fasten boxes rigidly to substrates or structural surfaces to which attached, or solidly embed electrical boxes in concrete or masonry. Use bar hangers for stud construction. 7. Supporting Devices: Provide supports, anchors, sleeves and seals as required for a complete raceway support system, including but not limited to: clevis hangers, riser clamps, c-clamps, beam clamps, one and two hole conduit straps, offset conduit clamps, expansion anchors, toggle bolts, threaded rods, U-channel strut system, and all associated accessories. Install in accordance with manufacturer ’s written instructions and with recognized industry practices to insure supporting devices comply with requirements. Provide rigid attachment of all floor mounted equipment to the floor slab or structural system. 8. Electrical Seismic Control: Provide seismic control equipment including but not limited to: vibration isolators, flexible connections, rigid steel frames, anchors, inserts and attachments, seismic snubber and bracing to meet the seismic requirements for the project site. 9. Wiring Devices: Provide grade factory-fabricated wiring devices, in types, and electrical ratings for applications indicated and complying with NEMA STDS Pub No. WD-1. Provide heavy duty specification grade, 20- amperes rated, grounding type convenience outlets,. Provide 20- amperes rated toggle switches. Construct wiring device of heavy duty high impact nylon and provide cover plates to match. Provide devices in colors selected by Architect. 10. 11. Panelboard and Switchboards: Provide galvanized sheet steel cabinet type enclosures, in sizes and NEMA types as indicated, code-gage minimum 16-gauge thickness. Provide dead front safety type panelboards with door-in-door hinged fronts. Equip with Copper bus bars, full-sized neutral and ground bus. Provide enclosures fabricated by same manufacturer as overcurrent devices. Bolt engraved plastic laminate labels indicating panel name and voltage on the interior and exterior of panelboard or switchboard. Overcurrent Protective Devices: Provide Overcurrent Protective Devices of the same manufacturer as the switchboard and/or panelboard manufacturer. Provide factory-assembled devices of amperage, voltage, and rms interrupting rating shown. Provide devices as follows: a. Molded Case Thermal Trip Circuit Breakers: i. Provide factory-assembled bolt-on molded case circuit breakers with permanent thermal trip and adjustable instantaneous magnetic trip in each pole. Series rating is not acceptable. Construct breakers for mounting and operating in any physical position and in an ambient temperature of 40 degrees C. ii. Circuit breakers 15 amps through 599 amps shall be molded case solid-state circuit breakers. b. Molded Case Solid-State Circuit Breakers i. Provide factory assembled bolt-on molded case circuit breakers UL listed for application at 100% of their continuous ampere rating. ii. Circuit breakers 600 amps through 1199 amps shall be molded case solid-state circuit breakers. iii. Solid-state trip mechanisms shall have the following functions: Adjustable long time ampere rating; adjustable long time delay; short time pick up- adjustable short time delay; adjustable instantaneous pick up. c. Insulated Case Circuit Breakers i. Provide factory assembled bolt-on insulated case circuit breakers with solid-state trip mechanisms and manual spring charging mechanism. Breakers shall be UL listed for application at 100% of their continuous ampere rating. ii. Circuit breakers 1200 amper and larger shall be insulated case circuit breakers. iii. On service disconnect breakers where phase to ground voltage exceeds 150-volts, the solid state trip mechnaism shall include adjustable ground fault pick up and adjustable ground fault time delay with ground fault test button; Over/Under voltage trip; Current imbalance trip. iv. Provide an energy-reducing maintenance switch with local, lit status indicator to allow for a reduction fo the instantaneous pickup and instantaneous delay settings. Device shall mount in face of dead-front. d. Fusible Switches i. Privde factory-assembled fusible switch units for individual mounting and four mounting within power distribution panelboard and switchboards. Provide siwtch units with quick-make, quick-break mechanisms, visible blades and dual horsepower ratings. Series rated ems are not acceptable. Equip with locable handles with on/off indication. Interlock switch covers and handles. e. Ground Fault Protection i. Provide solit-state ground-fault relay that requires no external source of power. Construct with adjustable pick-up current sensitivity for ground fault current from 200 to 1200 amperes, with calibrated dial to show pick-up point settings. Provide factory set time delay of 1.5 seconds and protection that precludes tampering with setting after installation. 12. 13. Lighting Fixtures: Provide lighting fixtures complete with all components for each size, type, and rating indicated. This includes, but not limited to housing, driver, reflectors, and wiring. Size fuses per ballast manufacturer ’s recommendation. Provide all necessary supports, brackets, and miscellaneous equipment for mounting of fixtures. Support all ceiling mounted fixtures from the building structure with #12 ga. steel wire attached to each corner; independent of the ceiling system. Provide backing supports. Provide gypsum board protection as required to maintain fire rating of each ceiling in which fixtures are installed. Provide all exterior fixtures with damp or wet location label as required by application. Provide Class 2 wiring for all fixtures indicated to have 0-10v dimming. Electrical identification: a. Provide electrical identification products for buried electrical lines, arc-flash hazard labels (ANSI Z535.4), source of supply labels, available fault current labels and emergency operating signs to equipment installed as part of this project. b. Provide coverplates that match devices with etched panel name and circuit number supplying the device. c. Provide permenant labels on coverplates indicating source of power (i.e. Panel - Circuit www.sunrise-eng.com WASHINGTON, UT 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] ENGINEERING 635 South State Street Salt Lake City, Utah 84111 P:[PHONE REDACTED] F:[PHONE REDACTED] www.bnaconsulting.com BNA CONSULTING SALT LAKE ST.GEORGE ---PAGE BREAK--- OC OC 1. PROVIDE PULL ROPE IN ALL EMPTY CONDUITS. 2. REFER TO CONDUCTOR SIZING CHART ON COVER SHEET FOR MINIMUM CONDUCTOR SIZE BASED ON CIRCUIT GENERAL SHEET NOTES S1 PROPOSED LOCATION OF NEW POLE MOUNTED TRANSFORMER. REFER TO ONE-LINE DIAGRAM FOR MORE INFORMATION. S2 PROPOSED LOCATION OF SERVICE METER TO BE MOUNTED ON EXTERIOR FOR RESTROOM BUILDING. REFER TO ONE-LINE DIAGRAM FOR MORE INFORMATION. S3 LOCATION OF EXISTING IRRIGATION CONTROLLER. PROVIDE CONTROLLER WITH DEDICATED 120V CIRCUIT IN RESTROOM BUILDING USING 1" CONDUIT. S4 LOCATION OF PRE-MANUFACTURED RESTROOM BUILDING. REFER TO CIVIL DRAWINGS AND BUILDING SHOP DRAWINGS FOR MORE INFORMATION. S5 A NEW IRRIGATION CONTROLLER WILL BE INSTALLED INSIDE RESTROOM BUILDING MECHANICAL ROOM. COORDINATE WITH RESTROOM BUILDING MANUFACTURER TO PROVIDE CONTROLLER WITH DEDICATED 120V CIRCUIT. S6 PROVIDE 1" CONDUITS FROM RESTROOM BUILDING PANEL TO IN-GRADE JUNCTION BOX SHOWN. REFER TO DIAGRAM L010 FOR IN-GRADE JUNCTION BOX REQUIREMENTS. S7 LOCATION OF PAVILION. PROVIDE PAVILION WITH RECEPTACLES AND LIGHT FIXTURES AS SHOWN. MOUNT RECEPTACLES ON PAVILION POSTS IN OPPOSITE CORNERS. CONCEAL ALL SURFACE MOUNTED CONDUIT AS MUCH AS POSSIBLE AGAINST STRUCTURAL ELEMENTS. REFER TO CIVIL DRAWINGS PAVILION SHOP DRAWINGS FOR MORE INFORMATION. EXTEND 1" CONDUIT FROM IN-GRADE JUNCTION BOX AND PROVIDE DEDICATED 120V CIRCUIT FOR RECEPTACLES AND LIGHTS SHOWN. WIRE RECEPTACLES TO BE "HOT" AT ALL TIMES. LIGHT FIXTURES HAVE INTEGRAL SENSORS FOR CONTROL. www.sunrise-eng.com WASHINGTON, UT 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] ENGINEERING 635 South State Street Salt Lake City, Utah 84111 P:[PHONE REDACTED] F:[PHONE REDACTED] www.bnaconsulting.com BNA CONSULTING SALT LAKE ST.GEORGE ---PAGE BREAK--- www.sunrise-eng.com WASHINGTON, UT 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] ENGINEERING 635 South State Street Salt Lake City, Utah 84111 P:[PHONE REDACTED] F:[PHONE REDACTED] www.bnaconsulting.com BNA CONSULTING SALT LAKE ST.GEORGE ---PAGE BREAK--- UNDERGROUND HANDHOLE (11"X18") L010 DIAGRAM 11-1/2" 18-1/2" 18" 1/2" 20-1/2" 3/4" 3/8"-16 UNC STAINLESS STEEL HEX HEAD BOLT WITH WASHER QUAZITE PC1118HG00 COVER GASKETTED HEAVY DUTY W/4 BOLTS ENGRAVE PER UTILITY AS APPLICABLE 'ELECTRICAL' OR 'SIGNAL' 13-1/2" GASKET QUAZITE PC1118BG18 OPEN BOTTOM WITH GASKET TOP FLUSH WITH ADJACENT SURFACE TO SLOPE 1/2" PER FOOT AWAY FOR 2 FEET GASKET 200 #NYLON PULL CORD 2" 2'-6" GRAVEL SUMP RIGID (WRAPPED) ELBOW AND VERTICAL RUN CONDUIT ENTRY, CAP FOR FUTURE USE BUSHING TYPICAL MAIN ELECTRICAL SERVICE GROUNDING F020 DIAGRAM UFER (2/0 AWG) BUILDING STEEL 6' MIN. 3/4"x10' GROUND RODS METAL WATER PIPE GROUNDING CONDUCTOR PVC SLEEVE MAIN ELECTRICAL SERVICE EQUIPMENT MAIN BONDING JUMPER EGB IBT F019 EXX 5' MAX 20' MIN. 2" MIN. IBT - BONDING TERMINAL #6 CU BC ≤ 25'-#4 CU ≤ 50'-#1 CU ≤ 75'-#2/0 CU > 75'-#3/0 CU BC SIZE CONDUIT BELOW SLAB U007 DIAGRAM SAND BED 4" MIN. ROAD BASE FLOOR SLAB 4" SAND 4" 2" MIN. SAND 4" MIN. SAND FLOOR SLAB SAND BED 4" MIN. ROAD BASE 8" MIN. FROM BOTTOM OF CONCRETE TO TOP OF CONDUITS 2" SAND NOTES: 1. SEE SPECIFICATION FOR ALL INSTALLATION REQUIREMENTS. 2. INSTALL DETECTABLE MARKING TAPE FOR ALL UNDERGROUND WIRING. SEE SPECIFICATION FOR MORE INFORMATION. MARKING TAPE: 6-8" BELOW FINISHED GRADE MARKING TAPE: 6-8" BELOW FINISHED GRADE DEVICE MOUNTING HEIGHTS NTS FLOOR LINE 16" MIN. 48" MAXIMUM TYPICAL REFLECTED CEILING HORN/STROBE INSTALL SPEAKERS AND SMOKE DETECTORS IN SAME LAY-IN TILE WHERE DEVICES ARE SHOWN IN SAME WALL SPACE, ALIGN VERTICALLY AND HORIZONTALLY AS SHOWN. COORDINATE WITH ARCHITECTURAL DRAWINGS & CABINETRY DRAWINGS 96" TYPICAL WALL SECTION R001 S DIAGRAM J VOLUME CONTROL WALL PHONE LIGHT SWITCH OUTLET DATA OUTLET FIRE ALARM PULL STATION JUNCTION BOX OUTLET DISTANCE DETERMINED BY ARCHITECT MILLWORK www.sunrise-eng.com WASHINGTON, UT 84780 11 NORTH 300 WEST TEL [PHONE REDACTED] Z FAX [PHONE REDACTED] ENGINEERING 635 South State Street Salt Lake City, Utah 84111 P:[PHONE REDACTED] F:[PHONE REDACTED] www.bnaconsulting.com BNA CONSULTING SALT LAKE ST.GEORGE