Full Text
SUBMITTAL Yes Revise Accept PROPOSED FLOOR PLANS. Clear plans showing proposed area, Dimensions of each room and space, Use of each room and space, Egress plan, Window/Door locations with sizes, A statement indicating that actual construction will comply with applicable local ordinances and building codes. Accessibility details. ENERGY CODE COMPLIANCE. Show R-values of slab, walls floors, and ceiling. Window U-factors. Permit applications and inspection requests can be made online by visiting If a project is over 3000 square feet, or when structural elements are being changed, a registered design professional shall prepare and stamp the plans. BUILDING DEPARTMENT MILLCREEK Is the property within FEMA Floodplain Zones A, AE, AO, or an Alluvial Fan? (click on Flood Plain layer within the Geological Features Map) Always identify floodplain on cover sheet of plans and reference source, elevations, and obtain any floodplain permits required. Please contact the Millcreek Flood Plain Manager for more information. millcreek.us Millcreek 3330 South 1300 East Millcreek, Utah 84106 Phone: (801) 214-2700 2015 International Residential Code (IRC) and MKZ 19.02.090 Building And Use Permits Required MKZ 19.02.090 Building And Use Permits Required CODE ANALYSIS. Note applicable building codes, Occupancy type, Construction type, Fire sprinkler and alarm requirements, Design occupant load, Restroom count, Floor area, Egress design, Note the compliance method used in the 2018 International Existing Building Code for remodeling existing buildings. CONTRACTOR INFORMATION SHEET. Name and contact information of who is performing the work. Dumpsters, restrooms, and material storage shall be kept on the property and off city streets, sidewalks and adjacent properties. Dumpsters can be stored on the street for a maximum of one week by obtaining a dumpster encroachment permit from the Public Works Department. Please visit PROPERTY ADDRESS: Refer to for more information and documents. (i.e. Apply for a permit, request an inspection, adopted construction codes, forms and links, climate and geographic design, and FAQ's) Note sheet/page number in plans COMMERCIAL ALTERATION BUILDING PERMIT REQUIREMENTS Certain commercial uses require an approval from the Salt Lake County Health Department. Please visit their website for more information. DATE: EXISTING FLOOR PLANS. Clear plans showing the current use and layout of the area. Label all features to be demolished, specifically any load bearing members. SCOPE OF WORK. An itemized list of work that is being proposed. Project description. Please visit the Utah Department of Air Quality for more information about demolition requirements. quality/asbestos-renovation-or-demolition APPLICANT NAME: GENERAL Locate valuable information using the millcreek.us "Map Gallery" at Remember, this is meant to be a helpful guide, not a comprehensive list. (CHECKMARK EACH BOX AND SUBMIT WITH APPLICATION) ---PAGE BREAK--- Deferred FIRE SPRINKLER AND ALARM PLANS. Fire sprinkler and alarm design. This must be submitted to Unified Fire Authority for approval before installation. ELECTRICAL PLANS. One line electrical diagram with the location of all lights, switches, outlets, Location of smoke and CO detectors, Note GFCI on required outlets, Location of meters and panels, electrical load calculations. Emergency lighting. DEFERRED SUBMITTALS PLUMBING PLANS. Location of water heater, location of all plumbing fixtures, shut-off valves, location of all floor drains. Gas line diagram. STRUCTURAL PLANS. Footing, foundation, posts, and/or beam sizes and schedules, General notes and details. GAS LINE DIAGRAM. A complete drawing including pipe size, length, BTU's of each appliance on gas line and meter size. Include longest length and CFH. MECHANICAL PLANS. Heat loss calculations, Equipment Sizing, Duct Sizing. Engineered mechanical plans. Manual J/D/S. MECHANICAL PLANS. Location of furnace, Location and size of supply/return ducts, Location of exhaust fans, Location of combustion air, Manual J/D/S. STRUCTURAL CALCULATIONS. Show all applicable design loads and calculations. MILLCREEK Yes Additional Comments: Revise Accept ELECTRICAL PLANS. Please show a complete electrical load calculation including service amperage requirements, One line diagram, Panel Schedules, Com-checks. Engineered design. Note sheet/page number in plans COM-CHECK. Must be site specific. Envelope and lighting com-check. TRUSS DESIGN AND CALCULATIONS. These drawings must be stamped by a design professional and approved by the engineer of record. PLUMBING PLANS. Water line sizes and calculations, pipe insulation, Drainage fixture units and sewer design. Grease interceptor location and pipe sizes. Engineered design. INSTALLATION MANUALS AND LISTINGS. ES Report, UL Listing, ETL Listing, Manufacturer Installation Instructions, Product Manual. Please Identify Any Documents That Will Be Deferred. These Documents Must Be Reviewed By The Millcreek Building Department Prior To Installation. ---PAGE BREAK--- ---PAGE BREAK--- ---PAGE BREAK---