← Back to Millcreek

Document Millcreek_doc_53d819dd3a

Full Text

SUBMITTAL Yes Revise Accept Millcreek 3330 South 1300 East Millcreek, Utah 84106 Phone: (801) 214-2700 DATE: Remember, this is meant to be a helpful guide, not a comprehensive list. PROPERTY ADDRESS: millcreek.us ONE, TWO FAMILY DWELLING, AND TOWNHOMES BUILDING PERMIT REQUIREMENTS APPLICANT NAME: GENERAL (CHECKMARK EACH BOX AND SUBMIT WITH APPLICATION) Locate the Building Department webpage by visiting Refer to for more information and documents. (i.e. Apply for a permit, request an inspection, adopted construction codes, forms and links, climate and geographic design, and FAQ's) SITE PLAN AND ELEVATIONS Permit applications and inspection requests can be made online by visiting Is the lot part of a recorded subdivision? If so, What is the name and lot number of the subdivision? Is there an overall drainage plan in place for the entire subdivision? If so, ensure the overall drainage plan is followed for the lot. MILCREEK NOTE OF SCALE USED. Must be scaled with dimensions and measurements. A scale of 1”=10' is typical, but others may be acceptable. DIRECTION OF NORTH POINT. Indicating the direction North. LOT LINES. Together with adjacent streets, roads and rights-of-ways, public utility easements, access easements, and irrigation and canal easements, etc. UTILITY LOCATIONS. Show where water, sewer, electric, and gas utility lines and meters are located. Is the property within FEMA Floodplain Zones A, AE, AO, or an Alluvial Fan? (click on Flood Plain layer within the Geological Features Map) Always identify floodplain on cover sheet of plans and reference source, elevations, and obtain any floodplain permits required. What zones apply to the property? (Go to Map Gallery on millcreek.us, then click on the Planning Zoning Public Map ) Click on property and follow links to the Salt Lake County Accessors webpage for more information regarding the property configuration, size and legal description. Are there any waterbodies near or adjacent to property? (click on appropriate layer) If part of an existing subdivision, were there any exceptions, special conditions, notes, etc.? Does property fall within a Fault Study Area (Go to Map Gallery on millcreek.us, then click on each Geological Feature Map . Click on layers to identify applicable features. Is Liquefaction Potential moderate or high? (click only on the Liquefaction layer only, then the subject parcel MKZ 19.02.080 Site Plans And Building Elevations Required; Contents MKZ 19.02.080 Site Plans And Building Elevations Required; Contents Note the total project cost on the application. This must include labor and materials. Dumpsters, restrooms, and material storage shall be kept on the property and off city streets, sidewalks and adjacent properties. Dumpsters can be stored on the street for a maximum of one week by obtaining a dumpster encroachment permit from the Public Works Department. Please visit SETBACKS. Note setback measurements from lot lines to structures. Note sheet/page number in plans requirement is satisfied 1 New Residential (One Two Family Dwellings and Townhomes) ---PAGE BREAK--- SUBMITTAL Yes Revise Accept Deferred DEFERRED SUBMITTALS ENERGY CODE COMPLIANCE. Show R-values of slab, walls floors, and ceiling. Window U-factors. SHOW ORIGINAL GROUND SURFACE. Label all points along each elevation of the building. Refer to MKZ 19.04.095 "Building, Height Of" for definitions. PROPOSED FINISH GRADE AT ALL POINTS ALONG EACH ELEVATION OF THE BUILDING. LOT LINES. Each elevation view shall show all applicable lot lines. EXPLANATORY NOTES DESCRIBING MATERIALS. Including percentages of each material on each facade. STRUCTURAL PLANS. Footing, foundation, posts, and/or beam sizes and schedules, General notes and details. BUILDING AND OPEN SPACE COVERAGES. Include percentages showing minimums and maximums are met. NAMES, ADDRESS, TELEPHONE NUMBER OF BUILDER AND OWNER. Include subdivision name and lot number if applicable. MOTOR VEHICLE ACCESS. Show individual parking stalls and identify covered stalls. LABEL ZONES. Include whether the single family, two family, or twin home is located in the Residential Compatibility Overlay Zone, Ch. 19.71 of the MKZ. Note sheet/page number in plans MILLCREEK Yes Please Identify Any Documents That Will Be Deferred. These Documents Must Be Reviewed By The Millcreek Building Department Prior To Installation Revise Accept PLUMBING PLANS. Location of water heater, location of all plumbing fixtures, shut-off valves, location of all floor drains. Gas line diagram. LOCATION OF THE NEAREST FIRE HYDRANT. Note sheet/page number in plans BUILDING DEPARTMENT MILLCREEK 2015 International Residential Code (IRC) and MKZ 19.02.090 Building And Use Permits Required MKZ 19.02.090 Building And Use Permits Required CODE ANALYSIS. Note applicable building codes, use, and square footage. FINISHED FLOOR LEVELS. Including all levels of a building, including but not limited to, basements, garages, patios, and decks. TOP OF FOOTING ELEVATIONS. An elevation certificate will be required at footing inspection. TOTAL HEIGHT OF HOME. Identify total height as measured from original ground surface to the highest point of the coping of a flat roof, or to the deck line of a mansard roof, or to the highest point of a pitched roof or hipped roofs, or gambrel roofs NECESSARY EXPLANATORY NOTES. Address any requirements particular to the zone(s). ALL OTHER INFORMATION THAT MAY BE REQUIRED, AS DETERMINED BY THE DIRECTOR. Include any previous approvals such as LUHO approval, CUP letter, or an RCOZ B/C approval, variances, Foothill Canyons Overlay Zone (FCOZ) approval letter. Click here for the FCOZ Chapter 19.72 of the MKZ ORIENTATION OF EACH ELEVATION. (NORTH, SOUTH, EAST and WEST) STRUCTURAL CALCULATIONS. Show all applicable design loads and calculations. MECHANICAL PLANS. Location of furnace, Location and size of supply/return ducts, Location of exhaust fans, Location of combustion air, Manual J/D/S. ELECTRICAL PLANS. One line electrical diagram with the location of all lights, switches, outlets, Location of smoke and CO detectors, Note GFCI on required outlets, Location of meters and panels, electrical load calculations. CONTRACTOR INFORMATION SHEET OR OWNER BUILDER CERTIFICATION. Name and contact information of who is performing the work. SCOPE OF WORK. An itemized list of work that is being proposed. Project description. CONSTRUCTION PLANS. Clear plans showing area, Dimensions of each room and space, Use of each room and space, Window/Door locations with sizes, A statement indicating that actual construction will comply with applicable local ordinances and building codes. 2 New Residential (One Two Family Dwellings and Townhomes) ---PAGE BREAK--- SUBMITTAL SUBMITTAL Yes Revised Accept MAXIMUM LOT COVERAGE. The lot coverage of all structures on the lot shall be not more than the percentages given in Table I, column FRONT YARD. The minimum front yard setback shall be as specified in the applicable City code. DIMENSIONS between buildings, and from buildings (including overhangs and projections) to all property lines. Refer to required setbacks of each zone and RCOZ. LOCATIONS AND SQUARE FOOTAGES of all existing and/or proposed driveways, walkways, decks, patios and other impervious surfaces, indicating surface materials and dimensions. USE of each building or area (garage, residence, ADU, shop, shed, etc.). Include retaining walls, rockeries, and the like. REAR YARD. The minimum rear setback of the primary residence and any accessory building shall be as specified in the applicable City code. RCOZ (Residential Compatibility Overlay Zone ) Chapter 19.71.030 of the MKZ (if located in any R-1, R-2, or A-1 Zones ) HEIGHT of all structures, fences, decks, retaining walls, rockeries and other similar elements from original ground surface/existing grade. LOT COVERAGES. Area of impervious surfaces and supporting calculations. Provide separate subtotals for buildings, driveways/parking areas, and walkways/patios. Identify existing, proposed, and replaced impervious surfaces. PROPERTY INFORMATION, including relevant zoning code, topography, site features, etc., for your property may be obtained from PLANNING AND ZONING DEPARTMENT General requirements needed and example can be located at RES-CHECK. Must be site specific. Must pass by a minimum of 5% if designed under the Utah State ammendments. TRUSS DESIGN AND CALCULATIONS. These drawings must be stamped by a design professional and approved by the engineer of record. WATER LINE CRITERIA. Show size of new water meter and service line with calculations. ELECTRICAL LOAD CALCULATIONS. Please show a complete electrical load calculation including service amperage requirement. INSTALLATION MANUALS AND LISTINGS. ES Report, UL Listing, ETL Listing, Manufacturer Installation Instructions, Product Manual. Note sheet/page number in plans requirement is satisfied MAXIMUM BUILDING HEIGHT. Maximum Building Height. Each point on the highest ridge of the structure shall be no more than that specified in Table I, column for the zone in which the property is situated. Maximum building height shall be measured in feet from that point on the original grade vertically below the referenced ridge height (not including chimneys and vent stacks). MILLCREEK MILLCREEK SIDE YARD. The combined side yard setbacks for any main structure shall be at least twenty-five percent of the lot width with no side setback less than eight feet. For purposes of this provision, "lot width" is the diameter of the largest circle that can be inscribed entirely within the lot, not including streams, floodplains, wetlands, areas of thirty percent slope or greater or other natural hazard areas. No extensions, bay windows or similar building elements may encroach into the required setbacks under Option A, except for attached air conditioning units, electrical boxes, utility meters and the like and roof overhangs or eaves that extend no more than two feet into the area of the minimum side setback. Yes Revise Accept MKZ Chapter 19.71.030 Note sheet/page number in plans requirement is satisfied Reviewed By The Millcreek Building Department Prior To Installation. MANUAL J/D/S. Heat loss calculations, Equipment Sizing, Duct Sizing. GAS LINE DIAGRAM. A complete drawing including pipe size, length, BTU's of each appliance and meter size. Include longest length and CFH. 3 New Residential (One Two Family Dwellings and Townhomes) ---PAGE BREAK--- SUBMITTAL GABLES. A gable may exceed the graduated height envelope, provided: BUILDING ENVELOPE. The height of all structures is further limited by the building envelope created by starting at a point eight feet above ground at each point on the property line of the lot and extending on a line at a forty- five degree angle from the vertical toward the interior of the lot, the projection of such line on the horizontal plane of the lot to be perpendicular to the property line. The entire building must fit under this envelope except for dormers and gables that satisfy the following limitations: DORMERS. A dormer may exceed the graduated height envelope, provided: The width of the dormer is no more than fourteen feet; MKZ Chapter 17.24, Chapter 19.75 and Title 14 Note sheet/page number in plans requirement is satisfied Yes Revise With multiple dormers, the distance to the front, or side edges of the roof is at least one-half the distance between dormers; and The dormer is no higher than the ridge of the roof. Accept MILLCREEK PUBLIC IMPROVEMENTS. Sidewalk, Curb, and Gutter are required along the frontage; if any of these items already exist, add a note that any damaged sidewalk, C&G must be replaced prior to issuance of C of O. Follow Millcreek Standard Plans 140 and 145 (see link below). Refer to Title 14 at Chapter 14.12 STANDARDS FOR ROADWAY DEVELOPMENT for standards and specifications. LOCATE CANALS AND DITCHES. Include any irrigation or canal company approval letter. NATURAL HAZRADS. Identify all potential hazards including but not limited to avalanche, liquefaction, surface fault rupture, and faults. EROSION CONTROL PLANS. Show and Identify the following: Silt fence or fiber roll to prevent silt and sediment from leaving the site. Storm drain inlet protection. Concrete Washout. Dumpster. Portable Toilet. Material Storage Area. Tracking pad at construction entrance. GRADING AND DRAINAGE PLANS. Grading and drainage plan showing existing contours and proposed contours with drainage arrows. Show storm drain calculations if new dwelling(s) will be disturbing one-acre or more. Check for canals on or adjacent to subject property. Cannot route stormwater to canals without canal co. permission. Owner to work with canal co. if moving, piping, etc. IDENTIFY AND LOCATE FLOOD ZONE OR PATHWAY DESIGNATION. Label FEMA Floodplain Zones A, AE, or an Alluvial Fan. IDENTIFY CENTERLINE OF ADJACENT STREETS WITH DISTANCE FROM CENTER LINE TO PROPERTY LINE. Label Adjacent Streets as Public or Private LIQUEFACTION DESIGNATION. Label Liquefaction Potential (moderate or high?) Use the neolocal features map and click only on the Liquefaction layer only, then the subject parcel. MKZ Chapter 17.24, Chapter 19.75 and Title 14 The height of the gable is no more than 1.75 times higher than the point where the graduated height envelope intersects the gable; and The height of the gable is less than the maximum building height. MASS AND SCALE. To avoid a large, continuous building mass of uniform height; no portion of any building shall continue more than forty feet horizontally without a minimum of an eighteen-inch break in the roofline or an architectural element such as an overhang, projection, inset, material and textural change to create shadow patterns along the elevation of the building. The elements required by this section are in addition to all other requirements under this Part. ENGINEERING DEPARTMENT Refer to the R-1 Zone Fact Sheet and the RCOZ Users Guide located on the Millcreek Planning and Zoning webpage for guides and examples. 4 New Residential (One Two Family Dwellings and Townhomes) ---PAGE BREAK--- Date: Comments: SENSITIVE LANDS. Property on or near sensitive lands (greater than 30%, near a water body, etc.) 5 New Residential (One Two Family Dwellings and Townhomes) ---PAGE BREAK--- 6 New Residential (One Two Family Dwellings and Townhomes) ---PAGE BREAK--- 7 New Residential (One Two Family Dwellings and Townhomes) ---PAGE BREAK--- 8 New Residential (One Two Family Dwellings and Townhomes)