← Back to Lafayette

Document Lafayette_doc_ae20aacc5c

Full Text

Building o Le o A be sp On‐Site F o N a fr o C ou o H m Knox Box o C ac Fire Prot o S m o F o F o F o C o F ex p Rubbish o C su so o D p Address: egible from th All rear and sid e addressed pace or busin Fire Hydrant No obstruction nd rear and u ont. Clear height to utlet of at leas Hydrants subje must properly x: Contains prope ccess codes tection Syste ystems prope maintained: ire sprinkler s ire alarm syst ire standpipe Commercial co ire departmen xterior of the rotective caps Containers: Containers sho ubject to smo ources. Dumpsters gre rovided with l Fire he street. de access doo or labeled to ness it serves ts: ns within 3’ of unobstructed f o bottom of lar st 1 foot. ect to vehicula protected from er keys & app for your busin ems: erly inspected system tem system ooking hood s nt connection building is un s or covers. ould not be lo oking material eater than 5-1 ids. Lafay Code S ors should indicate the . the sides from the rge hose ar damage m vehicles. plicable ness. d & system n (FDC) on nobstructed – ocated where s or ignition /3 cubic feet yette Fir Self-Insp Port o o o o o o o Com o o Stor o o o Com o o o o o re Depa pection table Fire Ex o Minimum general-p o 75 feet m o K-rated e kitchen h o Annual in o 6-year ma water ext o 12-year h maintena extinguis o 5-year hy dioxide (C mbustible Ru o Removed o Stored in approved rage of Mate o No storag o Maintaine o Maintaine head defl mbustible Sto o Must be o hazard to o Storage i o Boiler roo o Mechanic o Electrical artment Guide S xtinguishers m 5-pound A-B purpose areas maximum trave extinguisher fo ood systems nspection requ aintenance fo tinguishers. hydrostatic tes ance for dry ch hers. ydrostatic test CO2) extingu ubbish: d at least daily approved co d locations. erials and Eq ge in aisles or ed 2 feet belo ed 18 inches lectors. orage: orderly and n o people. s prohibited i om cal room l equipment ro Sheet s: B-C type for s. el distance. or commercia . uired. or dry chemic st and hemical or wa t for carbon ishers. y. ontainers loca quipment: r corridors. ow ceiling. below sprinkl ot present a n: oom al al or ater ated in ler ---PAGE BREAK--- Fueled Equipment: o Storage prohibited within buildings, unless specially designed for that purpose. Means of Egress: ` o Clear and unobstructed at all times. o Path of exit travel clearly identified. o Doors easily distinguishable as an exit door. o Emergency power/lighting operational. Exit Door Locks: o Operational and appropriate for exit type. o Must be operable from inside without use of keys, special effort or special knowledge during normal business hours. Panic Hardware (if applicable): o Operational and appropriately located on or about the door. Exit Lights: o Operational and visible from means of egress. o Illuminated when building is occupied. Electrical Hazards: o Portable electric heaters should be 3 feet from combustible materials. o All electrical cords should be in good condition with no abrasions, cuts, splits, or frays. Plug connections should not be altered or damaged. o Extension cords should be used only with portable equipment. o Electrical outlets shall have approved protective covers. o Electrical control panels front area unobstructed for a minimum width of 30 inches and a height of 6 feet. o Electrical panels breakers properly labeled. o Breakers or protective blanks are required on all panels. Flammable and Combustible Liquids: o No smoking in storage or use areas. o Where permitted indoor storage shall not exceed 10 gallons. o All storage shall be in approved flammable liquid storage containers. Hazardous Materials: o All materials should be stored in approved containers. o Storage areas should be identified by signs or placards. Contact the Lafayette Fire Prevention Bureau ([PHONE REDACTED]) for chemical specific storage, use and handling requirements.