← Back to Lafayette

Document Lafayette_doc_6f65af8f3c

Full Text

Deck / Pergola Checklist submittal requirements Items required for Electronic Submittal – incomplete submittals will not be accepted ☐ Completed application including project description, electrical valuation, total project valuation, square footage ☐ Site Plan showing the deck footprint, dimensions of the deck, height off the ground, property line setbacks (front, side, and rear as applicable) ☐ A copy of AOA (homeowners association) approval if applicable ☐ A Framing plan that includes the following: ☐ Caisson layout, size, and depth (36 inch minimum) ☐ Post layout, size, and spacing ☐ Beam layout, size, and spacing ☐ Joist size and spacing ☐ Identify any cantilevers (at both the house and the deck). Note: The deck cannot attach to a house cantilever without engineer stamped approval and the maximum cantilever for both beams and joists that can be accepted without an engineer’s stamp is 2 feet ☐ Identify the location of any windows that are within 60 inches of the deck stairs ☐ Identify the location of all stairs including the type of landing at the bottom ☐ Identify handrails and guard rails where required Design Information Codes: International Residential Code 2021 National Electrical Code 2023 International Energy Conservation Code 2021 Windspeed: 105 mph 3 second gust, single family Risk Category 1 Vult – 120 mph Risk Category 2 Vult – 135 mph Risk Category 3, 4 Vult – 145 mph Frost Depth: 36-inch front depth Snow Load: 30 lbs./sq.ft Deck / Pergola Permit Checklist 1290 S. Public Road, Lafayette Colorado 80026 [EMAIL REDACTED] I [PHONE REDACTED]