Full Text
+ + + + + + CORNER DISTANCE FROM EDGE OF STRAP TO CORNER IS 1 1/2" + + + + + + + + + + + + + + + + + + + + + + + + + + + HEADER 3/8" MINIMUM SHEATHING 8d SHEATHING NAIL-OFF 3" O.C. EACH WAY FULL LENGTH DOUBLE STUDS STHD10 NAILED OFF WITH 16d NAILS SIMPSON STRONG-TIE SHEAR PANEL NAIL-OFF @ CITY OF KALISPELL BUILDING DEPARTMENT DETAILS NOT TO SCALE DOUBLE STUDS ARE REQUIRED FROM THE BOTTOM PLATE TO THE TOP PLATE 23 1/8" STRAP LENGTH 23 1/8" DOUBLE STUDS FULL LENGTH 16 INCHES MINIMUM 16" MINIMUM PANEL WIDTH SHEAR PANELS LESS THAN 16" IN WIDTH REQUIRES PROFESSIONAL ENGINEERING MINIMUM GARAGE DOOR SHEAR PANELS ALTERNATE BRACING REQUIREMENTS HEADERS MUST RUN TO EACH END OF THE SHERE PANEL 16" WIDE PANELS (16" TO 48") 2 SINMPSON STHD10 STRAPS AE REQUIRED AT EACH PAEN. A MINIMUM APA RATED SHEATHING APPLIED ON ONE SIDE OF THE PANEL FROM THE BOTTOM PLATE TO THE TOP PLATE WITH 8d COMMON OR GALV. NAILS 3" O.C. WALLS EXCEEDING 8' IN HEIGHT REQUIRE SOLID BLOCKING AT THE JOINTS THE HEADER MUST RUN TO THE END OF EACH PANEL. AT EACH CORNER OF GARAGE WALLS WITH GARAGE DOOR OPENINGS A 48" SHEAR PANEL IS REQUIRED. AREAS NOT ALLOWING A 48" SHEAR PANEL AN ALTENATE PANAL MAY BE USED.