← Back to Everett

Document Everett_doc_fcc6eaec09

Full Text

1 CITY OF EVERETT BUILDING DEPARTMENT, 3200 CEDAR ST, EVERETT, WA 98201 [PHONE REDACTED] www.everettwa.org NEW COMMERCIAL AND MULTI-F I.CONSTRUCTION DOCUMENTS A. Include a code data section on the coversheet to include the occupancy classifications, types of constr Architect’s stamp. All projects over 4,000 square feet or more than 4 dwelling units require the plans t Foundation plans and details.D. Floor plan with complete dimensions. Indicate the proposed use of each space. Show all exit doors, Building section with vertical dimensions and building construction details.F. Wall sections indicating proposed construction and assembly ratings as required for occupancy separat Exterior elevations (all sides) indicating proposed materials, finish grade and building height.H. Stair or ramp plans (1/4” = 1’ minimum scale) and sections.I. Toilet room plans (1/4” = 1’ minimum scale) and interior elevations, indicate wall and floor finishes, fix Land use reviews (SEPA, etc.) if required, must be completed prior to permit submittal. Includ Three sets of building plans that include site and landscape plans PLUS an additional four se Maximum size of plan sets: 42” long, 30” wide (bound edge), 5/8” thick. All pages in a plan set Twosetsof documentation i.e. storm water/drainage analysis, soils reports, engineering Completed Permit Application6. Plan check fee 7.All documents must be clearly legible for microfilming, each page consecut ---PAGE BREAK--- 2 CITY OF EVERETT BUILDING DEPARTMENT, 3200 CEDAR ST, EVERETT, WA 98201 [PHONE REDACTED] www.everettwa.org I.CONSTRUCTION DOCUMENTS (continued)J. Schedules: door, window, room finish and hardware.K. Lighting plan and energy budget calculations (indicate wattage of all fixtures, include exterior building Proof of compliance with the Washington State Energy Code including envelope insulation details.M. Structural drawings and calculations to include design loads, material specifications and structural sc Copies of any permits/approvals issued by the Planning Department.O. High-piled combustible storage (if applicable). Plans and specifications submittal per Chapter 23, S Hazardous materials (if applicable). Hazardous materials management plans and inventory statements Automatic Fire Detection & Suppression Systems Ordinance No. 1902-92 International Building Code (IBC), 2012Edition & WAC 51-50 Accessible and Usable Buildings & Facilities, ANSI A117.1-2009& WAC 51-50-005 International Fire Code (IFC), 2012Edition & WAC 51-54 International Mechanical Code (IMC), 2012Edition & WAC 51-52 NationalElectrical Code (NEC), 2008Edition & WAC 296-46B-010 Uniform Plumbing Code (UPC), 2012Edition & WAC 51-56 & 51-57 InternationalEnergy Conservation Code (IECC), 2012Edition, WAC 51-11(C or City of Everett Design & Construction Standards & Specifications Everett Stormwater Management (rev 7/13) ---PAGE BREAK--- BUILDING ENCLOSURE SUBMITTAL CHECKLIST FOR NEW OR TENANT IMPROVEMENTS TO MIXED-USE, MULTI-FAMILY OR TOWNHOUSE BUILDINGS EXEMPT BUILDINGS: Hotels, motels, dormitories, care facilities, floating homes, mixed-use buildings with maximum of two residential attached dwelling units or less, duplexes, and townhouses (as defined by the IRC) where each unit is on a single platted lot (approved and recorded zero lot line subdivisions). 3 PERMIT AND CERTIFICATE OF OCCUPANCY SUBMITTAL REQUIREMENTS 1. A letter from the applicant certifying that the cost of the construction work on the building enclosure is equal to or less than 5% of the assessed building value*, in addition to the building permit application and two sets of construction plans; or, 2. A certified recorded copy of the “Sale Prohibition Covenant” per RCW 64.55 in addition to the building permit application and two sets of construction plans; or, 3. Two complete sets of construction plans (per the building permit application submittal for „New Commercial and Multi-Family‟, „Tenant Improvement‟, or „Residential‟ which meet WA State RCW 64.55 requirements for building enclosure certifications;Maximum size of plan se 4. Completed Permit Application; 5. Plan check fee as applicable; and, 6. All documents must be clearly legible for microfilming NOTE- Applications are accepted between the hours of 8:00 AM and 4:00 PM only. *Internet reference for assessed building value, subject to change and verification of single building value: http://web5.co.snohomish.wa.us/propsys/Asr-Tr-PropInq/PrpInq01-Entry.asp The City of Everett will not review or approve plans or inspect the work required by RCW 64.55 but will collect the required submittals for RCW 64.55 as noted on this checklist. I. REQUIRED PRIOR TO ISSUING A BUILDING PERMIT A. The building enclosure design documents submitted for permit should include details and specifications to protect the building or its components from water or moisture intrusion, including details of flashing, intersections at roof, eaves or parapets, means of drainage, water-resistive membrane, and details around openings. These documents should be submitted prior to the start of new construction or rehabilitative construction. B. Building enclosure design documents must contain a stamped statement by the Washington State licensed architect or engineer in substantially the following form: “The undersigned has provided building enclosure documents that in my professional judgment are appropriate to satisfy the requirements of RCW 64.55.005 through 64.55.090.” REQUIRED PRIOR TO SCHEDULING FINAL INSPECTION A. A qualified inspector (a special inspector retained by the owner at their cost) shall prepare and submit a signed letter certifying to the City of Everett Building Department Building Official that the building enclosure has been inspected during the course of construction or rehabilitative construction and that it has been constructed in substantial compliance with the submitted building enclosure design documents. APPLICABLE CODES AND REFERENCES  Chapter 64.55 RCW Construction Defect Disputes-Multiunit Residential Buildings, effective date 8/01/2005. Internet reference: http://apps.leg.wa.gov/RCW/default.aspx?cite=64.55  Chapter 64.34 RCW Washington Condominium Act (rev 8/5/09) ---PAGE BREAK--- 4 com and condo (rev 4/23/08) FOR OFFICE USE ONLY RCW REHABILITATIVE CONSTRUCTION, NEW CONSTRUCTION, RECORDED COVENANT OR CONVERSION CHECK ONE BOX Property Name Address Building Number Permit Number □ REHABILITATIVE CONSTRUCTION equal to or less than 5% or less of current assessed market improvement value of specified building* *NOTE: Applicant to provide entire cost of rehabilitative construction to the building enclosure for a multiunit residential building or mixed use project per RCW 64.55.010, which may exceed the valuation for building permit. □ NEW CONSTRUCTION OR REHABILITATIVE CONSTRUCTION equal to more than 5% of current assessed market improvement value of specified building* *NOTE: Per RCW 64.55.010, RCW 64.55.020 and RCW 64.55.060 Each building enclosure design document is to be stamped and signed by a Washington State architect. The documents should also contain a stamped signed statement by the same architect that “the undersigned has provided building enclosure documents that in my professional judgment are appropriate to satisfy the requirements or RCW 64.55.005 through 64.55.090”. Final inspection or „Certificate of Occupancy' cannot be issued by the building department prior to receipt of a signed letter from an independent inspector certifying that the building enclosure has been inspected during the course of construction and has been constructed in substantial compliance with the building enclosure design documents. □ RECORDED COVENANT OF SALE from Snohomish County* *NOTE: Sale Prohibition Covenant per RCW 64.55.010 Submit site plan with location of building, permit with description of work and certified copy of recorded covenant from the real property records of Snohomish County, Washington for specified building. □ CONVERSION to condominium* *NOTE: permits may be required by the City of Everett per the results of the independent inspection report. Undersigned will comply with owner independent inspection alternative per RCW 64.55.090 and RCW 64.34.400(2). Signatur