1 CITY OF EVERETT BUILDING DEPARTMENT 3200 CEDAR ST, EVERETT, WA 98201 [PHONE REDACTED] www.everettwa.org RESIDENTIAL CONSTRUCTION S I. SITE (PLOT) PLAN  A site plan is required. See attached site plan checklist and sample drawing.II. STRUCTURAL PLANS  Show all four elevationswith roof pitch, materials, finished floor level&plate height(s) Foundation plan (cross section and plan view) showing: rebar placement, slab, ventilation, access, an Floor plans showing: each story or level, all rooms labeledfor use, dimensions of rooms, location of Total square footage: livingspace, garage, covered porches, deck(including stairs) Cross section –exterior(s) –all materials/connections Cross section –interior(s) structural framing PERMIT SUBMITTAL REQUIREMENTS:1. Completed Permit Application form2. Two complete sets of building plans (1/4” = 1’ minimum scale) and One additional reduc Three siteplans, no larger than 11” x 17” in size and to scale = 20’ minimum scale). Maximum size of plan sets: 42” long, 30” wide (bound edge), 5/8” thick. All pages in a plan set Two copies of engineering calculations if required, and one copy of soils or other report Plan check fee7. 1 copy of any Land Use decision if applicable.NOTES: All documents must be clearly legib ---PAGE BREAK--- 2 CITY OF EVERETT BUILDING DEPARTMENT 3200 CEDAR ST, EVERETT, WA 98201 [PHONE REDACTED] www.everettwa.org  Floor framing plan showing: each story, all support pads, posts, beams, sizes, connections, all header Stair cross section showing: construction, fireblocking, headroom, handrailsize and height, riser he Masonry fireplace/chimney detail(s) Building section(s)specific to this structure Roof framing plan(s) showing: trusses, girder truss, hipmaster, special trusses. If stick frame show: si All structural garage details: plan view, cross section, wall and ceilingseparation. All structural deck details: pressure treatedwood, all support pads, post&beamsizes, connectio SYSTEMS ANALYSIS (Chapter 4) –building heating/cooling load calculations COMPONENT PERFORMANCE APPROACH (Chapter 5) –thermal performance calculations inc PRESCRIPTIVE REQUIREMENTS APPROACH (Chapter 6) –completed compliance application re Foundation walls over 8 feet  Retaining wall over 4 feet Sheer and lateral bracing of walls not complying with IRC R602.10 and Table R602.10.1APPLICABL International Residential Code (IRC), 2012Edition & WAC 51-51 International Fire Code (IFC), 2012Edition & WAC 51-54 National Electrical Code (NEC), 2008Edition & WAC 296-46B-010 Uniform Plumbing Code (UPC), 2012Edition & WAC 51-56, 51-57 InternationalEnergyConservationCode(IECC), 2012Edition, WAC 51-11R City ofEverett Design & Construction Standards & (rev 10/13) ---PAGE BREAK--- ---PAGE BREAK--- ---PAGE BREAK--- ---PAGE BREAK---