← Back to Cortlandcountyny Gov

Document cortlandcountyny_gov_doc_ec1690b635

Full Text

Using Air Monitoring Device to Determine the Presence of CO Gas Air Monitoring – 2002 Edition, NFPA 472 6.2.1.3 NEW YORK STATE DEPARTMENT OF STATE Skill Sheet 29-1 Candidate's Name Date Evaluator's Name Evaluator's Signature The candidate, given a complete set of PPE and SCBA and given an air monitoring device in a simulated possible carbon monoxide environment, shall determine the presence of carbon monoxide in accordance with Delmar, Firefighter’s Handbook, 2 ed., NYS ed. Time limit for this station is 10 minutes. 02/2007 Criteria: Pass Fail Clears/calibrates monitor prior to entering simulated environment Enters simulated environment with full PPE and SCBA (activated) Samples atmosphere in two locations (two samples) Verbally reports both sample results Safely exits simulated atmosphere Evaluator Notes