Emergency Scene Illumination Emergency Scene Illumination – 2002 Edition, NFPA 1001 5.1.1.2, 5.3.1, 5.3.17 NEW YORK STATE DEPARTMENT OF STATE Skill Sheet 20-1 Candidate's Name Date Evaluator's Name Evaluator's Signature The candidate, given a complete set of PPE and a portable electric generator, electric extension cords, and portable lighting equipment, employing all safety precautions and operating individually, shall illuminate an area(s) as directed by the evaluator in accordance with Delmar, Firefighter’s Handbook, 2 ed., NYS ed. Time limit for this station is 10 minutes. 02/2007 Criteria: Pass Fail Considers grounding of generator (may be verbalized) Assures generator readiness and performance (checks fuel/oil) Identifies limitations of power supply equipment (load cannot exceed amperage of circuit breaker, total load cannot exceed output of generator, and fuel dependent) Identifies hazards associated with electric generating equipment (wet environment, tight connections, and ventilation of exhaust Operates equipment within manufacturer’s guidelines Illuminates area(s) as directed Evaluator Notes