Full Text

Ventilation – Roof Ventilation Ventilation – 2002 Edition, NFPA 1001 5.3.11 NEW YORK STATE DEPARTMENT OF STATE Skill Sheet 18-1 Candidate's Name Date Evaluator's Name Evaluator's Signature The candidate, given a complete set of PPE, SCBA and a selection of hand and power tools, shall correctly and safely open a roof for vertical ventilation in accordance with Delmar, Firefighter’s Handbook, 2 ed., NYS ed. Time limit for this station is 15 minutes. 02/2007 Criteria: Pass Fail Brings necessary tools to roof Checks for signs of unsafe conditions Properly verbalizes techniques to students Finds appropriate location for opening Locates roof supports Opens inspection hole Verbalizes appropriate size for opening Candidate cuts opening in roof while a second firefighter ensures safety Tools used safely Roof supports are not cut Area completely cleared of all roofing material Opening cleared to fire area Evaluator Notes