← Back to Columbia County, GA

Document Columbiacountyga_doc_8347d7f066

Full Text

APPENDICES Sanitary Sewer Extension Forms Appendix A Water Line Extension Form Development – Water Supply & Demand Calculations Appendix B Water System Demand and Sanitary Sewer Contribution Form (Single Site Only) Appendix AB Water Meter Flow & Head Loss Design Information Appendix C Project Construction Cost Form Appendix D Sewer Flow Test Request Form Appendix E Water Flow Test Request Form Appendix F GDOT Encroachment Permit Check List Appendix G Sanitary Sewer Basin Map & WWTP Locations Appendix H Water System Pressure Zone Map Appendix I Development Plan Review Check List DPRC-1 thru 2 Final Plat / Easement Plat Review Check List PRC-1 As Built Review Check List ARC-1 ---PAGE BREAK--- Columbia County Board of Commissioners Stacey W. Gordon, P.E. Division Director P.O. Box 960 Grovetown, Columbia County, GA 30813 ---PAGE BREAK--- ---PAGE BREAK--- ---PAGE BREAK--- ---PAGE BREAK--- ---PAGE BREAK--- Appendix B.docx Appendix B Columbia County Water Utility Water Line Extension Form Development – Water Supply & Demand Calculations Name of Developer: Project Name & Type of Number of Proposed gpm per Lot: District: Number of Lots Previously Approved but not yet Constructed:____________ gpm per Lot: Required Fire Flow: (gpm) Size(s) of Water Main in Project: Total Length:___________(feet) Material:_________ Total Length:___________(feet) Material:_________ Total Length:___________(feet) Material:_________ Flow Test Information: a) Static Pressure (point of tie-in):______(psi) at elevation Size of Water Main at b) Maximum Elevation in Development: c) Flow Available:____________ (gpm) at (psi) residual, at the point of tie-in. d) Date of Flow Test: Test Performed By: Include all 24-hour pressure test results for projects connecting to existing systems. Flow test cannot be more than 6 months old. The Columbia County Water Supply System can sufficiently supply the requirements of this subdivision as well as those previously approved and not yet constructed. Water main material and size within the project area are adequate to meet minimum pressure requirements of 20psi at peak demand. The water system will be owned, operated and maintained by the Columbia County Water Utility Department. Wastewater for this Project will be handled by: Septic Tank:□ or Sewer System: □ (check one) Professional Engineer Information Name of Design Firm Name of Design Engineer: P.E. # ___________Expiration Date Mailing P.E. Signature Date Authorized Representative: Name Signature Title Date Pressure System (Zone) ---PAGE BREAK--- Appendix AB Columbia County Water Utility Engineering Department Water System Demand & Sanitary Sewer Contribution Form (Single Site Only) Project Location of Name Design PE # PE Water Estimated Domestic Water Demand gallons per minute Estimated Irrigation Water Demand gallons per minute Estimated Peaking Factor Sanitary Sewer Estimated Sanitary Sewer Contribution gallons per day (gpd): Estimated Peaking Factor Sewer: Please note for daily or business hour usages accordingly. Flows must reflect an actual amount contributing to the system. For example, businesses operating from 9am to 5pm, Monday through Friday. Gallons per Day equal the number of gallons contributing within a 24 hour period. Sanitary Sewer See Appendix H for Basin Map Information ---PAGE BREAK--- Appendix C APPENDIX C Water Meter Flow and Head Loss Design Information ---PAGE BREAK--- CONFORMANCE TO STANDARDS The iPERL system far exceeds the most recent revision of ANSI/AWWA Standard C-700 and C-710 for accuracy and pressure loss requirements. All iPERL systems are NSF/ANSI Standard 61 Annex F and G compliant and tested to AWWA standards. PERFORMANCE The patented measurement technology of the iPERL system allows enhanced accuracy ranges at both low and high flows and perpetual accuracy over the life of the product and can be installed horizontally, vertically or diagonally. CONSTRUCTION The iPERL system is an integrated unit that incorporates an electronic register and measuring device encased in an external housing. The measuring device is comprised of a composite alloy flowtube with externally-threaded spud ends. Embedded in the flowtube are magnetic flow sensors. The all electronic, programmable register is hermetically sealed with a tempered glass cover. The iPERL system has a 20 year life cycle, along with a 20 year battery life guarantee. ELECTRONIC REGISTER The high resolution 9-digit hermetically sealed electronic register with LCD display was designed to eliminate dirt, lens fogging issues and moisture contamination in pit settings with built in tamper protection. The tempered glass register cover displays readings with the AMR digits highlighted. Direction of flow and units of measure are also easily readable on the register display. The iPERL register features; AMR resolution and unit of measure that are fully programmable, integral customer data logging compatible with UniPro software tools. The large, easy to read display also includes battery life, empty pipe and forward/reverse flow indicators. TAMPERPROOF FEATURES The integrated construction of the iPERL system prevents removal of the register to obtain free water. The magnetic tamper and low field alarms will both indicate any attempt to tamper with the magnetic field of the iPERL system. AMR / AMI SYSTEMS iPERL systems are compatible with current Sensus AMR/AMI systems. Features Description 5/8” (DN 15mm), 3/4” (DN 20mm) and 1” (DN 25mm) Sizes With no moving parts, the Sensus iPERL water management system is based on innovative electromagnetic flow measurement technology. The iPERL system family has an operating range as low as 0.03 gpm (0.007 m3/ hr) to 55 gpm. WDS-10006-02 iPERL TM Water Management System Electromagnetic Flow Measurement System Electronic Register LCD Display ---PAGE BREAK--- SERVICE Measurement of potable and reclaim water. Operating temperature range of 33 oF (0.56 oC) - 150 oF (65.6 oC) NORMAL OPERATING FLOW RANGE 5/8” (DN 15mm) size: 0.18 to 25 gpm (0.04 to 5.7 m3/hr) 3/4” (DN 20mm) size: 0.18 to 35 gpm (0.04 to 8.0 m3/hr) 1” (DN 25mm) size: 0.4 to 55 gpm (0.09 to 12.5 m3/hr) LOW FLOW RANGE 5/8” (DN 15mm) size: >0.11 gpm (0.025 m3/hr) to <0.18 gpm (0.041 m3/hr) 3/4” (DN 20mm) size: >0.11 gpm (0.025 m3/hr) to <0.18 gpm (0.041 m3/hr) 1” (DN 25mm) size: >0.3 gpm (0.068 m3/hr) to <0.4 gpm (0.09 m3/hr) STARTING FLOW 5/8” (DN 15mm) size: 0.03 gpm (0.007 m3h) 3/4” (DN 20mm) size: 0.03 gpm (0.007 m3h) 1” (DN 25mm) size: 0.11 gpm (0.025 m3h) MAXIMUM OPERATING PRESSURE 200 psi (13.8 bar) MEASUREMENT TECHNOLOGY Solid state electromagnetic flow REGISTER Hermetically sealed, 9-digit programmable electronic register AMR/AMI compatible iPERL system register programmable using the UniPro programming package MATERIALS External housing – Thermal plastic Flowtube – Polyphenylene sulfide alloy Electrode – Silver/silver chloride Register cover – Tempered glass ALARM DEFAULTS Alarm Duration – 90 days Leak Duration – 24 hours Datalog Interval – 1 hour Alarm Mask – All alarms reported History Mask – All event types reported WDS-10006-01 Page 2 of 3 SPECIFICATIONS DIMENSIONS AND NET WEIGHTS Size A (lay length) B C Spud Ends NPSM Thread Size Width Net Weight 5/8” (DN 15 mm) 7-1/2” (190 mm) 6-1/10” (155 mm) 1-3/4” (44 mm) 5/8” (15 mm) 3/4” (19 mm) 4-1/2” (114 mm) 3.1 lb. (1.4 kg) 3/4”S (5/8” x 3/4”) (DN 20 mm) 7-1/2” (190 mm) 6-1/10” (155 mm) 1-3/4” (44 mm) 3/4” (20 mm) 1” (25 mm) 4-1/2” (114 mm) 3.1 lb. (1.4 kg) 3/4” (DN 20 mm) 9” (229 mm) 6-1/10” (155 mm) 1-3/4” (44 mm) 3/4” (20 mm) 1” (25 mm) 4-1/2” (114 mm) 3.2 lb. (1.5 kg) 1” (DN 25 mm) 10-3/4” (273 mm) 6-1/10” (155 mm) 1-3/4” (44 mm) 1” (25 mm) 1-1/4” (32 mm) 4-1/2” (114 mm) 3.3 lb. (1.6 kg) ” ---PAGE BREAK--- 8601 Six Forks Road, Suite 700 Raleigh, NC 27615 1-[PHONE REDACTED] www.sensus.com/water © All products purchased and services performed are subject to Sensus’ terms of sale, available at either; http://na.sensus.com/TC/TermsConditions.pdf or 1-[PHONE REDACTED]. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. WDS-10006-01 Page 3 of 3 HEADLOSS CURVES 1” Headloss Curve 3/4” Headloss Curve 3/4” Short Headloss Curve 5/8” Headloss Curve ---PAGE BREAK--- SCOPE These specifi cations set forth the minimum acceptable design criteria and performance requirements for cold water meters - Fire Service type consisting of a Class II turbine type meter, and a ductile iron strainer assembly. This meter assembly is intended where an extremely wide fl ow range is required and where measurement of both domestic and fi re service water usage is desired. CONFORMANCE TO STANDARDS The meter package shall meet or exceed all requirements of AWWA Standard C703 for Class II. The measuring shall be so confi gured to capture all fl ows as specifi ed, without the requirement of an automatic valve. Each meter assembly shall be performance tested to ensure compliance. Each meter package shall meet or exceed all requirements of NSF/ANSI Standard 61, Annex F and G. MAINCASES The meter maincase shall be of an epoxy coated iron composition. The epoxy coating shall be provided as standard fusion-bonded and adhere to NSF for non-lead regulation compliance. PERFORMANCE The meter assembly shall have performance capability of continuous operation up to the rated maximum fl ows as listed below without affecting long-term accuracy or causing any undue component wear. The meter assembly shall also provide a 25% fl ow capacity in excess of the maximum fl ows listed for intermittent fl ow demands. Maximum headloss through the meter / strainer assembly shall not exceed those listed in the following table per meter size. OPERATING CHARACTERISTICS Meter Size Low Flow (95% Min.) Operating Range (98.5 - 101.5%) Intermittent Flows (98.5 - 101.5%) Pressure Loss (Not to Exceed) 4” 0.75 GPM 1.5 to 1000 GPM 1250 GPM 6.4 PSI @ 1000 GPM 6” 1.5 GPM 3.0 to 2000 GPM 2500 GPM 6.7 PSI @ 2000 GPM 8” 2.5 GPM 4 to 3500 GPM 4700 GPM 5 PSI @ 3500 GPM 10” 3.5 GPM 5 to 5500 GPM 7000 GPM 7 PSI @ 5500 GPM MEASURING CHAMBER The measuring chamber shall consist of a measuring element, removable housing, and all-electronic register. The measuring element shall be mounted on a horizontal, stationary titanium shaft with sleeve bearings and be essentially weightless in water. The measuring element comes integrated with the advanced Floating Ball Technology design. The measuring chamber shall be capable of operating within the above listed accuracy limits without calibration when transferred from one maincase to another of the same size. The measuring shall be so confi gured to capture all fl ows as specifi ed above, without the requirement of an automatic valve. DIRECT MAGNETIC DRIVE SYSTEM The direct magnetic drive shall occur between the motion of the measuring element blade position and the electronic register. The OMNI direct drive system with Floating Ball Technology is designed to extend service life, enhance low fl ow sensitivity and provide extended fl ow capacity and overall accuracy of the meter assembly. Additional intermediate, magnetic or mechanical, drive couplings are not acceptable. ELECTRONIC REGISTER The meter’s register is all-electronic and does not contain any mechanical gearing to display fl ow and accurate totalization. The electronic register includes the following partial list of features: • AMR resolution units fully programmable • Pulse output frequency fully programmable • Integral data logging capability • Integral resettable accuracy testing feature • Large, easy-to-read LCD display • 10-year battery life guarantee 8” and 10” Sizes (UL Listed and FM Approved) SP-W-OMF-00-00-0611-03-A OMNI TM F2 Specifi cations ---PAGE BREAK--- 8601 Six Forks Road, Suite 700 Raleigh, NC 27615 1-[PHONE REDACTED] www.sensus.com/water © All products purchased and services performed are subject to Sensus’ terms of sale, available at either; http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. MAXIMUM OPERATING PRESSURE The meter assembly shall operate properly without leakage, damage, or malfunction up to a maximum working pressure of 175 pounds per square inch (psig). STRAINERS Each meter assembly shall have a separate UL (Underwriters Laboratories) Listed and FM (Factory Mutual) approved external fi re service strainer as a part of the meter package. The strainer’s screen shall have a minimum net open area of at least four times the pipe opening and be a V-shaped stainless steel screen for the purpose of obtaining a full unobstructed fl ow pattern. The strainer body shall be coated iron with stainless steel fasteners capable of maintaining the following static pressure ratings and physical dimensions: Meter Size Maximum Working Pressure Centerline to Strainer Base Compact Overall Length (Not to Exceed) Standard Overall Length (Not to Exceed) 4” 175 PSIG 4-3/4 INCHES 33 INCHES 51-7/8 INCHES 6” 175 PSIG 5-3/4 INCHES 45 INCHES 67-5/8 INCHES 8” 175 PSIG 6-3/4 INCHES 53 INCHES 77 INCHES 10” 175 PSIG 8-1/2 INCHES 68 INCHES 90 INCHES STRAIGHTENING VANES A straightening vane assembly is mandatory and shall be positioned directly upstream of the measuring element. The straightening vane assembly shall be an integral component of the measuring chamber. CONNECTIONS The meter assemblies shall have fl anges of the Class 125 round type, fl at faced and shall conform to ANSI B16.1 for specifi ed diameter, drilling and thickness. CERTIFICATIONS AND MARKINGS All sizes of meter packages shall be UL (Underwriters Laboratories) Listed and FM (Factory Mutual) approved as being accepted for use on fi re service lines and domestic water use. For such applications, the meter shall have a UL/ FM listed and approved strainer immediately upstream of the inlet fl ange. The meter shall have an identifi cation tag affi xed indicating such acceptance and the strainer shall also bear such acceptance symbols and markings on the casting. GUARANTEE AND MAINTENANCE PROGRAM Meters shall be guaranteed against defects in material and workmanship for a period of one year from date of shipment. In addition, the meter supplier shall submit nationally published literature clearly outlining its factory maintenance program and current price schedule covering complete measuring chamber exchange. INTENT Subject meter specifi cations are designed to establish minimum guidelines for selecting an extremely critical metering device. Areas of concern to be evaluated in the selection process include, but are not limited to, ease of installation, operational features and benefi ts, readability and future system maintenance expense. A design, which refl ects longevity of proper operation in all elements and high degree of sustained accuracy within the entire range of the meter assembly, is to be considered mandatory. Enhanced accuracy levels and performance are desired and should not be compromised. RECOMMENDATION Sensus OMNI F2 Meter. SP-W-OMF-00-00-0611-03-A Page 2 of 2 ---PAGE BREAK--- DS-W-OMF-00-00-0611-02-A Page 2 of 3 SPECIFICATIONS DIMENSIONS AND NET WEIGHTS Meter and Pipe Size Normal Operating Range Connections A B C D E F G H J Net Weight Shipping Weight Standard Fireline 4” DN 100mm 1.5 gpm .34 m3/hr 1000 gpm 227 m3/hr Flanged 33” 838mm 13-11/16” 348mm 15/16” 24mm 17-1/2” 446mm 4-3/4” 121mm 7-1/2” 191mm 8 5/8” 16mm 2” 50mm 212 lbs. 96 kg. 252 lbs. 115 kg. 51-7/8” (1317mm) 6” DN 150mm 3.0 gpm .681 m3/hr 2000 gpm 454 m3/hr Flanged 45” 1143mm 15-3/4” 400mm 15/16” 24mm 22-3/8” 569mm 5-3/4” 146mm 9-1/2” 242mm 8 3/4” 19mm 2” 50mm 394 lbs. 179 kg. 449 lbs. 204 kg. 67-5/8” (1717mm) 8” DN 200mm 4 gpm .91 m3/hr 3500 gpm 795 m3/hr Flanged 53” 1346mm 18-1/2” 470mm 11/16” 17mm 31” 787mm 6-3/4” 172mm 11-3/4” 298mm 8 3/4” 19mm 2” NPT 736 lbs. 334 kg. 786 lbs. 357 kg. 77” (1956mm) 10” DN 250mm 5 gpm 1.1 m3/hr 5500 gpm 1249 m3/hr Flanged 68” 1727mm 22-1/4” 565mm 11/16” 17mm 37-1/3” 947mm 8-1/2” 216mm 14-1/4” 362mm 12 7/8 22mm 2” NPT 1155 lbs. 524 kg. 1215 lbs. 551 kg. 90” (2286mm) 1 Standard Fireline lay length with optional spool piece added. E D F - Bolt Circle G - No. of Bolts H - Size of Bolts { C A B Direction of Flow Strainer Screen Maincase F2 Rotor Strainer Cover Register with Pulse and AMR Test Plug Measuring Chamber Assembly J OMNI F2: 8” and 10” SERVICE Measurement of potable and reclaim water. Operating temperature range of 33 oF (56 oC) - 150 oF (65.6 oC) OPERATING RANGE (100% ± 1.5%) 1.5 – 1000 GPM (.34 - 227 m3/hr) 3.0 – 2000 GPM (.34 - 227 m3/hr) 4– 3500 GPM (0.91-795 m3/hr) 10”: 5– 5500 GPM (1.1-1249 m3/hr) LOW FLOW (95% – 101.5%) .75 GPM (.06 m3/hr) 1.5 GPM (.06 m3/hr) 2.5 GPM (0.57 m3/hr) 10”: 3.5 GPM (0.8 m3/hr) UL MINIMUM FLOW 97% @ 3 GPM (0.68 m3/hr) 10”: 97% @ 4 GPM (0.9 m3/hr) MAXIMUM CONTINUOUS OPERATION 1000 GPM (227 m3/hr) 2000 GPM (454 m3/hr) 3500 GPM (795 m3/hr) 10”: 5500 GPM (1249 m3/hr) MAXIMUM INTERMITTENT OPERATION 1250 GPM (284 m3/hr) 2500 GPM (568 m3/hr) 4700 GPM (1067 m3/hr) 10”: 7000 GPM (1590 m3/hr) PRESSURE LOSS 6.4 psi @ 1000 GPM (.60 bar @ 227 m3/hr) 6.7 psi @ 2000 GPM (.56 bar @ 454 m3/hr) 5 psi @ 3500 GPM (.34 bar @ 795 m3/hr) 10”: 7 psi @ 5500 GPM (.48 bar @ 1249 m3/hr) MAXIMUM OPERATING PRESSURE 175 PSI (12 bar) FLANGE CONNECTIONS U.S. ANSI B16.1 / AWWA Class 125 REGISTER Fully electronic sealed register with programmable registration (Gal. /Cu.Ft./ Cu. Mtr. / Imp.Gal / Acre Ft.) Programmable AMR/AMI reading and pulse outputs Guaranteed 10 year battery life NSF APPROVED MATERIALS Maincase: Measuring Chamber: Rotor “Floating Ball”: Radial Bearings: Thrust Bearings: Magnets: Strainer Screen: Strainer Cover: Test Plug: Coated Ductile Iron Thermoplastic Thermoplastic Hybrid Thermoplastic Sapphire/Ceramic Jewel Ceramic Magnet Stainless Steel Coated Ductile Iron Coated Ductile Iron ---PAGE BREAK--- 8601 Six Forks Road, Suite 700 Raleigh, NC 27615 1-[PHONE REDACTED] www.sensus.com/water © All products purchased and services performed are subject to Sensus’ terms of sale, available at either; http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. DS-W-OMF-00-00-0611-02-A Page 3 of 3 OMNI F2: 8” and 10” Headloss Curves 4" F2 Pressure Loss Curve with Strainer 0 1 0 5 0 100 200 [PHONE REDACTED] Rate of Flow (GPM) 0 4 2 6 8 10 12 14 Pressure Loss (PSI) 95 97 96 98 99 100 101 102 4" F2 Accuracy Curve 0 .5 1.5 10 50 100 200 [PHONE REDACTED] 101.5 98.5 Rate of Flow (GPM) Accuracy 6" F 2 Pressure Loss Curve with Strainer 0 2 5 5 0 [PHONE REDACTED] 1500 2000 2500 Rate of Flow (GPM) 0 4 2 6 8 10 12 14 Pressure Loss (PSI) 95 97 96 98 99 100 101 102 6" F 2 Accuracy Curve 0 1 3.0 25 50 [PHONE REDACTED] 1500 2000 2500 101.5 98.5 Rate of Flow (GPM) Accuracy 8" F 2 Pressure Loss Curve with Strainer 0 2 5 5 0 [PHONE REDACTED] 2000 3500 2500 Rate of Flow (GPM) 0 2 1 3 4 6 8 10 Pressure Loss (PSI) 95 97 96 98 99 100 101 102 8" F 2 Accuracy Curve 0 3 6 25 50 [PHONE REDACTED] 2000 3500 2500 101.5 98.5 Rate of Flow (GPM) Accuracy 10" F 2 Pressure Loss Curve with Strainer 0 2 5 5 0 [PHONE REDACTED] 2500 5500 2500 Rate of Flow (GPM) 0 3 1 5 6 8 10 12 Pressure Loss (PSI) 4500 95 97 96 98 99 100 101 102 10" F 2 Accuracy Curve 0 3 6 25 50 [PHONE REDACTED] 2500 5500 2500 101.5 98.5 Rate of Flow (GPM) Accuracy 4500 ---PAGE BREAK--- SCOPE These specifi cations set forth the minimum acceptable design criteria and performance requirements for Turbine- type cold water meters including the following potential service applications and general considerations: • Intended where a moderately wide fl ow range is anticipated • Measurement of water usage for typical billing applications • Measurement intended for typical commercial and industrial applications • Measurement of low fl ow usage above OMNI C2 Meter threshold levels • Measurement of constant medium to extended high fl ow usage CONFORMANCE TO STANDARDS The meter package shall meet or exceed all requirements of ANSI/AWWA Standard C701 for Class II turbine meter as- semblies. Each meter assembly shall be performance tested to ensure compliance. The meter package shall meet or exceed all requirements of NSF/ANSI Standard 61, Annex F and G. MAINCASES The meter maincase shall be of epoxy coated ductile iron composition. The epoxy coating shall be provided as stan- dard fusion-bonded and adhere to NSF for non-lead regula- tion compliance. PERFORMANCE The meter assembly shall have performance capability of continuous operation up to the rated maximum fl ows as listed below without affecting long-term accuracy or causing any undue component wear. The meter assembly shall also provide a 25% fl ow capacity in excess of the maximum fl ows listed for intermittent fl ow demands. Maximum headloss through the meter/strainer assembly shall not exceed those listed in the following table per meter size. OPERATING CHARACTERISTICS Meter Size Low Flow (95% Min.) Operating Range (98.5 - 101.5%) Intermittent Flows (98.5 - 101.5%) Pressure Loss (Not to Exceed) 1-1/2 .75 GPM 1.25 to 160 GPM 200 GPM 6.9 PSI @ 160 GPM 2” 1.0 GPM 1.5 to 200 GPM 250 GPM 7.0 PSI @ 200 GPM 3” 1.5 GPM 2.5 to 500 GPM 650 GPM 5.1 PSI @ 500 GPM 4” 2.0 GPM 3.0 to 1000 GPM 1250 GPM 8.7 PSI @ 1000 GPM 6” 2.5 GPM 4.0 to 2000 GPM 2500 GPM 8.2 PSI @ 2000 GPM 8” 4 GPM 5 to 3500 GPM 4700 GPM 5.1 PSI @ 3500 GPM 10” 5 GPM 6 to 5500 GPM 7000 GPM 7.2 PSI @ 5500 GPM MEASURING CHAMBER The measuring chamber shall consist of a measuring element, removable housing, and all-electronic register. The measuring element shall be mounted on a horizontal, stationary stainless steel shaft with sleeve bearings and be essentially weightless in water. The measuring element comes integrated with the advanced Floating Ball Technology design. The measuring chamber shall be capable of operating within the above listed accuracy limits without calibration when transferred from one maincase to another of the same size. The measuring shall be so confi gured to capture all fl ows as specifi ed above. DIRECT MAGNETIC DRIVE SYSTEM The direct magnetic drive shall occur between the motion of the measuring element blade position and the electronic register. The OMNI direct drive system with Floating Ball Technology is designed to extend service life, enhance low fl ow sensitivity and provide extended fl ow capacity and overall accuracy of the meter assembly. Any and all additional intermediate, magnetic or mechanical, drive couplings are not acceptable. ELECTRONIC REGISTER The meter’s register is all-electronic and does not contain any mechanical gearing to display fl ow and accurate totalization. The electronic register includes the following partial list of features: • AMR resolution units fully programmable • Pulse output frequency fully programmable • Integral data logging capability • Integral resettable accuracy testing feature • Large, easy-to-read LCD display • 10-year battery life guarantee 1-1/2”, 8” and 10” Sizes SP-W-OMT-00-00-0611-04-A OMNI TM T2 Specifi cations ---PAGE BREAK--- 8601 Six Forks Road, Suite 700 Raleigh, NC 27615 1-[PHONE REDACTED] www.sensus.com/water © All products purchased and services performed are subject to Sensus’ terms of sale, available at either; http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. MAXIMUM OPERATING PRESSURE The meter assembly shall operate properly without leakage, damage, or malfunction up to a maximum working pressure of 200 pounds per square inch (psig). STRAINERS The meter strainer shall be integral and cast as part of the meter’s maincase. The strainer’s screen shall have a minimum net open area of at least two times the pipe opening and be a V-shaped confi guration for the purpose of maintaining a full unobstructed fl ow pattern. The strainer body shall be a coated ductile iron fusion-bonded epoxy identical to that of the meter’s maincase. All fasteners shall be stainless steel capable of maintaining the following static pressure ratings and physical dimensions: Meter Size Maximum Operating Pressure Centerline to Strainer Base Overall Length (Not to Exceed) 1-1/2” 200 PSIG 2-5/16 INCHES 13 INCHES 2” 200 PSIG 2-5/16 INCHES 17 INCHES 3” 200 PSIG 4-1/8 INCHES 19 INCHES 4” 200 PSIG 4-3/4 INCHES 23 INCHES 6” 200 PSIG 5-3/4 INCHES 27 INCHES 8” 200 PSIG 6-3/4 INCHES 30-1/8 INCHES 10” 200 PSIG 8-1/2 INCHES 41-1/8 INCHES STRAIGHTENING VANES A straightening vane assembly is mandatory and shall be positioned directly upstream of the measuring element. The straightening vane assembly shall be an integral component of the measuring chamber. CONNECTIONS Flanges for the 1-1/2” and 2” size meter assemblies shall be of the 2-bolt oval fl ange confi guration. The 8” and 10” size meter assemblies shall have fl anges of the Class 125 round type, fl at faced and shall conform to ANSI B16.1 for specifi ed diameter, drilling and thickness. CERTIFICATIONS AND MARKINGS All sizes of meter packages shall display the sizes, model, manufacturer name, and direction of fl ow. Such display shall be cast on the side of the meter maincase. GUARANTEE AND MAINTENANCE PROGRAM Meters shall be guaranteed against defects in material and workmanship for a period of one year from date of shipment. In addition, the meter supplier shall submit nationally published literature clearly outlining its factory maintenance program and current price schedule covering complete measuring chamber exchange. INTENT Subject meter specifi cations are designed to establish minimum guidelines for selecting an extremely critical metering device. Areas of concern to be evaluated in the selection process include, but are not limited to, ease of installation, operational features and benefi ts, readability and future system maintenance expense. A design, which refl ects longevity of proper operation in all elements and high degree of sustained accuracy within the entire range of the meter assembly, is to be considered mandatory. Enhanced accuracy levels and performance are desired and will not be compromised. RECOMMENDATION Sensus OMNI T2 Meter SP-W-OMT-00-00-0611-04-A Page 2 of 2 ---PAGE BREAK--- DS-W-OMT-00-00-0611-03-A Page 2 of 5 OMNI T2: 1-1/2”, 8” and 10” Sizes DIMENSIONS AND NET WEIGHTS Meter and Pipe Size Normal Operating Range Connections A B C D E F G H J Net Weight Shipping Weight 1-1/2” DN 40mm 1.25 gpm .28 m3/hr 200 gpm 45 m3/hr Flanged 13” 330mm 7-7/8” 200mm 15/16” 24mm 5-1/8” 130mm 2-5/16” 59mm 4” 102mm 2 5/8” 16mm 1” 25mm 18.8 lbs. 8.53 kg.. 22.5 lbs. 10.20 kg. 2” DN 50mm 1.5 gpm .34 m3/hr 250 gpm 57 m3/hr Flanged 17” 432mm 7-7/8” 200mm 1” 25mm 5-3/4” 146mm 2-5/16” 59mm 4-1/2” 114mm 2 3/4” 19mm 1-1/2” 40mm 27.4 lbs. 12.42 kg. 34.5 lbs. 15.65 kg. 2” without Strainer DN 50mm 1.5 gpm .34 m3/hr 250 gpm 57 m3/hr Flanged 10” 254mm 7-7/8” 200mm 1” 25mm 5-3/4” 146mm 2-5/16” 59mm 4-1/2” 114mm 2 3/4” 19mm N/A 17.4 lbs. 7.9 kg. 24.5 lbs. 11.11 kg. 3” DN 80mm 2.5 gpm .57 m3/hr 650 gpm 148 m3/hr Flanged 19” 432mm 8-3/4” 222mm 3/4” 19mm 7-7/8” 200mm 4-1/8” 105mm 6” 153mm 4 5/8” 16mm 2” 50mm 48.5 lbs. 22.00 kg. 57.4 lbs. 26.04 kg. 4” DN 100mm 3.0 gpm .68 m3/hr 1250 gpm 284 m3/hr Flanged 23” 584mm 11-3/16” 284mm 15/16” 24mm 9-1/8” 232mm 4-3/4” 121mm 7-1/2” 191mm 8 5/8” 16mm 2” 50mm 67.9 lbs. 30.80 kg. 75.8 lbs. 34.38 kg. 6” DN 150mm 4 gpm .91 m3/hr 2500 gpm 568 m3/hr Flanged 27” 685mm 13-1/4” 336mm 15/16” 24mm 11” 279mm 5-3/4” 146mm 9-1/2” 242mm 8 3/4” 19mm 2” 50mm 140 lbs. 52.3 kg. 165 lbs. 61.6 kg. 8” DN 200mm 5 gpm 1.1 m3/hr 3500 gpm 795 m3/hr Flanged 30-1/8” 765 mm 15” 381 mm 11/16” 17 mm 13-1/2” 343 mm 6-3/4” 172 mm 11-3/4” 300 mm 8 3/4” 19 mm 2” NPT 471 lbs. 214 kg. 521 lbs. 236 kg. 10” DN 250mm 6 gpm 1.4 m3/hr 5500 gpm 1249 m3/hr Flanged 41-1/8 19” 485mm 11/16” 17mm 16” 406mm 8-1/2” 216mm 14-1/4” 362mm 12 7/8” 22mm 2” NPT 685 lbs. 311 kg. 745 lbs. 338 kg. E D F - Bolt Circle G - No. of Bolts H - Size of Bolts { C A B J Direction of Flow Strainer Screen Maincase T2 Rotor Strainer Cover Register with Pulse and AMR Test Plug Measuring Chamber Assembly OMNI T2: 8” - 10” OMNI T2: 1 1/2” - 6” ---PAGE BREAK--- DS-W-OMT-00-00-0611-03-A Page 4 of 5 1.5" T 2 Pressure Loss Curve with Strainer 0 .75 1.25 7 1 5 3 0 5 0 8 0 100 160 200 Rate of Flow (GPM) Pressure Loss (PSI) 0 4 2 6 8 10 12 14 95 97 96 98 99 [PHONE REDACTED].5" T2 Accuracy Curve 0 .75 1.25 7 15 30 50 80 100 160 200 101.5 98.5 Rate of Flow (GPM) Accuracy OMNI T2: 1-1/2”, 8” and 10” Sizes Headloss Curves 2" T 2 Pressure Loss Curve with Strainer 0 1.0 1.5 7 1 5 3 0 5 0 8 0 100 200 250 Rate of Flow (GPM) 0 4 2 6 8 10 12 14 Pressure Loss (PSI) 95 97 96 98 99 100 101 102 2" T2 Accuracy Curve 0 1.0 1.5 7 15 30 50 80 100 200 250 101.5 98.5 Rate of Flow (GPM) Accuracy 95 97 96 98 99 100 101 102 3" T2 Accuracy Curve 0 1.5 2.5 10 50 100 200 300 400 500 650 101.5 98.5 Rate of Flow (GPM) Accuracy 4" T 2 Pressure Loss Curve with Strainer 0 1 0 5 0 100 200 [PHONE REDACTED] 1250 Rate of Flow (GPM) 0 4 2 6 8 10 12 14 Pressure Loss (PSI) 95 97 96 98 99 100 101 102 4" T2 Accuracy Curve 0 2.0 3.0 10 50 100 200 [PHONE REDACTED] 1250 101.5 98.5 Rate of Flow (GPM) Accuracy ---PAGE BREAK--- Appendix D.doc Columbia County, Georgia Project Construction Cost Date: Complete Name of Development (Section/Phase): Name of Developer: Name of Engineering Firm/Surveyor: Name of Contractor: Total Number of Total Roadway Total Total Sanitary Sewer Total Total Storm Sewer Total Total Water Total Total Sidewalk Total ---PAGE BREAK--- Appendix E Columbia County Water Utility Engineering/Inspections Department P.O. Box 960 – Grovetown, GA 30813 Phone: (706) 651-0433 Fax: (706) 651-0648 Sewer Flow Test Request Form Date: Project: Requested By: Phone Number: Email Billing Address: Size of Sanitary Sewer Line: Location of Test: Office Use Only Type of Sanitary Sewer Line: Test Performed By: Start Date: Finish Date: This form is also available on the website. The form can be completed and forwarded directly to the Engineering / Inspection Department for processing. www.columbiacountyga.gov Please email request to [EMAIL REDACTED] ---PAGE BREAK--- Appendix F Columbia County Water Utility Engineering/Inspections Department P.O. Box 960 - Grovetown, GA 30813 Phone: (706) 651-0433 Fax: (706) 651-0648 Water Flow Test Request Form Date: Project: Requested By: Phone Number: Email Address: Billing Address: Size of Water Line: Location of Test: Hydrant-1 Number (Static Hydrant) Hydrant-2 Number (Flow Hydrant) Office Use Only Test Performed By: Start Date: Finish Date: Pressure System Zone: This form is also available on the website. The form can be completed and forwarded directly to the Engineering / Inspection Department for processing. www.columbiacountyga.gov Please email request to [EMAIL REDACTED] ---PAGE BREAK--- COLUMBIA COUNTY WATER UTILITY GDOT UTILITY ENCROACHMENT PERMIT CHECK LIST Appendix Beginning mile point (distance from nearest intersection) Ending mile point (distance from nearest intersection) Traffic Control Type Work Description Estimated number of work days Impact bridge or wall attachments ( Yes or No ) Minimum distance from edge of pavement Maximum distance from edge of pavement Pipe size Pipe material Casing diameter Casing material Valve quality Manhole quantity Minimum depth of utility Maximum depth of utility Involves pavement cutting ( * Yes or No) Involves blasting ( Yes or No ) Location map ( pdf format ) Utility plan sheet ( pdf format ) Utility profile sheet ( pdf format ) [required for road bores] *Requires a pavement repair detail ---PAGE BREAK--- ---PAGE BREAK---