Full Text
VAULT LOCATION STYLE JENSEN CAT. NO. OLD CASTLE CAT. NO. ANAHEIM CU. NO. TRAFFIC TUB K814-FV112-163F ANA 814-114 DV V8X14CONT SCOPE: THIS STANDARD SHOWS DETAILS OF 8' x 14' x 9'-4" DISTRIBUTION VAULT, PARKWAY OR TRAFFIC INSTALLED. FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : NEW SHEET NEW SHEET APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS SYS PLN MGR SUB MAINT SR ELEC ENG. DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600*3F REV 11 11 06-21 1 5 CU 1600-3F ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : NEW SHEET NEW SHEET APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS SYS PLN MGR SUB MAINT SR ELEC ENG. DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600*3F REV 11 11 06-21 2 5 CU 1600-3F ITEM (PER SIDEWALL): A. 6" DIAMETER PVC CONDUIT TERMINATORS - 24 REQD. B. 1" DIAMETER PVC GROUND WIRE SLEEVE - 2 REQD. C. 1" DIA. x 6" DOUBLE COIL INSERT, GALV., 10,000 LB. PULL CAPACITY - 2 REQD. (SEE NOTE ABOVE) D. 1 5/8" x 1 5/8" x 48" LG. UNISTRUT WITH SHORT SLOTS, GALV., WITH 1/2" DIA. STAINLESS STEEL FASTENERS - 8 REQD. E. 1/2" DIA. IMPERIAL I-5000 PLASTIC INSERT - 16 REQD. F. 5/8" DIA. x 3 5/8" NC THREADED INSERT, 2000 LB LOAD CAPACITY - 2 REQD. G. 1/2" DIA. BRONZE GROUND INSERT, GROUND - 2 REQD. TO REINFORCEMENT BARS. H. 10" DIA. PLASTIC VENT COUPLING - 2 REQD. ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : NEW SHEET NEW SHEET APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS SYS PLN MGR SUB MAINT SR ELEC ENG. DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600*3F REV 11 11 06-21 3 5 CU 1600-3F ITEM (PER ENDWALL): A. 6" DIAMETER PVC CONDUIT TERMINATORS - 24 REQD. B. 1" DIAMETER PVC GROUND WIRE SLEEVE - 2 REQD. C. 1" DIA. x 6" DOUBLE COIL INSERT, GALV., 10,000 LB. PULL CAPACITY - 4 REQD. D. 1 5/8" x 1 5/8" x 48" LG. UNISTRUT WITH SHORT SLOTS, GALV., WITH 1/2" DIA. STAINLESS STEEL FASTENERS - 4 REQD. E. 1/2" DIA. IMPERIAL I-5000 PLASTIC INSERT - 8 REQD. F 5/8" DIA. x 3 3/8" NC THREADED INSERT 2000 LB. LOAD CAPACITY - 1 REQD. H. 10" DIA. PLASTIC VENT COUPLING - 1 REQD. ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : NEW SHEET NEW SHEET APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS SYS PLN MGR SUB MAINT SR ELEC ENG. DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600*3F REV 11 11 06-21 4 5 CU 1600-3F NOTES: A. 1" DIA. COIL INSERT, GALV. - 7 REQD. B. 5/8" DIA COPPER CLAD GROUND ROD, WELD TO REINFORCEMENT & PROJECT 3" MIN. - 2 REQD. C. 13" DIA. SUMP, 5" DEEP W/PLATE RECESS. L0CATE AS SHOWN. - 2 REQD. ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : NEW SHEET NEW SHEET APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS SYS PLN MGR SUB MAINT SR ELEC ENG. DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600*3F REV 11 11 06-21 5 5 CU 1600-3F GENERAL NOTES A. THE STRUCTURE SHALL MEET THE APPLICABLE REQUIREMENTS OF THE LATEST REVISED EDITIONS OF THE FOLLOWING STANDARDS: ACI318, ASTM C-857 & AASHTO (WHICH INCLUDES AASHTO H-20 TRAFFIC WHEEL LOADING). B. FOR VAULT DESIGN PURPOSES, USE 3' GROUND WATER TABLE LEVEL. C. INTERIOR WALLS AND CEILING SHALL BE PAINTED WITH 2 COATS FLAT WHITE PAINT. (FRAZEE #410 LATEX OR APPROVED EQUAL). D. ALL JOINTS SHALL BE GASKETED AND WATERTIGHT. E. EXCAVATIONS PER CU 1600-4B, MINIMUM SIZE: SEE MANUFACTURES SUGGESTED EXCAVATION SIZE. F. SEE CU 1600-4D FOR TYPICAL VAULT SETTING DETAILS. G. PANEL OR TUNNEL STYLE REQUIRE APPROVAL BY ELECTRICAL ENGINEERING DIVISION. H. TRAFFIC STYLE TO INCLUDE 1 ACCESS LADDER. J. FOR VAULT VENTING, SEE CU 1700-6. K. FOR SUMP PUMP INSTALLATION, SEE CU 1700-5. L. FOR VAULT IDENTIFICATION, SEE C0 114-10.