← Back to Anaheim, CA

Document Anaheim_doc_c8c75356c1

Full Text

DESIGN II 5' x 8'-6" x 6'-6" TRAFFIC 7'-6" 48" 36" 6" 6" 6" 9" 6" 9" 9" 9" 6" 48" 9" 9" 9" 36" 5'-0" (INSIDE) 8'-6" (INSIDE) 3A 3B 3C 2 1 5 7 4 6 1. BOTTOM SECTION 2. TOP SECTION 3A. 30"DIA FRAME & COVER W/ MARK " ANAHEIM ELECTRIC" I. JENSEN PART # K36-MN11-05 3B. CONE NECK I. 9"-MN36-N9 100012114 II. 12"-MN36-N12 100012113 3C. EXTENSION RING I. 3"-MN36-R3 100008557 II. 6"-MN36-R6 [PHONE REDACTED] III. 12"-MN36-R12 100012039 4. 13" x 14" DIA. SUMP x 5" DEEP W/GRATE & RECESS. BOTTOM SECTION 5. 7" DIA. KNOCKOUTS 6" CONDUIT MAX. TOP AND BOTTOM SECTION (56) 6. 12" x 18" KNOCKOUT x 4 1/2" DEEP. BOTTOM SECTION CORE MTD.;TOP SECTION CORE MTD. 7. 1 5/8" x 1 5/8" GALV. CAST-IN UNISTRUT x 24" LONG. BOTTOM SECTION (10) CORE MTD.; TOP SECTION (12) CORE MTD. 8. 5/8" GROUND ROD ATTACHED TO REBAR, 3" PROJECTION x 6" LONG, BOTTOM SECTION CORE MTD. 8 9 10 11 FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET UNDERGROUND VAULT 5' x 8'-6" x 6'-6" CU1600-3D REV9 9 07-21 1 2 CU 1600-3D TYPE COMPATIBLE UNIT NO. JENSEN UTILITY VAULT TRAFFIC V5X8-6X7CONT K586-FM78-16 COFA 856-78-MH MOVED PARKWAY STYLE TO MAINTENANCE 9. 1" SLEEVE W/ CAP, TOP SECTION CORE MTD. 10. 4 TON 9" GALV. RISS. BOTTOM SECTION SURFACE MTD. TOP SECTION CORE MTD., SUFACE MTD. 11. 1" DIA. COIL THR'D. INSERT. TOP AND BOTTOM SECTION CORE MTD. ---PAGE BREAK--- NOTES: 1. VAULT TO BE DESIGNED IN ACCORDANCE WITH AASHTO H-20-44 TRAFFIC BRIDGE LOADING USING 5,500 PSI [37.92MPa] COMPRESSIVE STRENGTH CONCRETE AND 60,000 PSI [413.2MPa] YIELD STRENGTH ASTM A-706 STEEL REINFORCEMENT PER CALCS. #31394. 2. VAULT TO BE PLACED ON A MIN. 6" BASE OF CRUSHER RUN FOR EASE OF INSTALLATION AND EVEN LOAD DISTRIBUTION. 3. SAFETY FLOOR PLATE FOR PARKWAY INSTALLATION TO BE GALVANIZED & MARKED ELECTRIC. 4. FOR HOLD DOWN BOLTS & SPRINGS, SPECIFY PARKWAY OR TRAFFIC USE. 5. ALL INTERIOR WALLS SHALL BE PAINTED WITH 2 COATS OF WHITE LATEX FLAT PAINT FRAZEE #410 OR EQUAL. 6. THIN WALL KNOCKOUTS MAY BE SUBSTITUTED, PARKWAY AND SOLID TRAFFIC COVER ARE BOTH AVAILABLE. FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET UNDERGROUND VAULT 5' x 8'-6" x 6'-6" CU1600-3D REV9 9 07-21 2 2 CU 1600-3D MOVED PARKWAY STYLE TO MAINTENANCE