← Back to Anaheim, CA

Document Anaheim_doc_bdb04f6b11

Full Text

200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax www.anaheim.net/building JAN 2018 B807 SINGLE-FAMILY DWELLING OR DUPLEX SUBMITTAL REQUIREMENTS Number of sets of plans and other information required for initial submittal:  Five sets of architectural/structural plans:  Two sets of energy calculations signed by the preparer, and two sets of structural calculations wet-stamped and wet-signed by the engineer/architect who prepares it.  Two sets of plans and calculations for prefabricated trusses if used.  Two copies of the Soils Report is required or qualify for Soils Report Waiver for Residential Structures (R-3 Occupancies). Please visit Grading plans are reviewed by Public Works Department-Engineering Services Division. For their grading procedures, please visit http://www.anaheim.net/322/Inspection Plans, drawn on 18” X 24” or larger paper, shall include the following: 1. Address and legal description of the property; owner’s name, address, and phone number. 2. Site plan showing the location of building/addition in relation to property lines, and any other existing structure(s), i.e. pool, shed, etc. A licensed survey is required if the new building/addition is located within one foot of the zoning code-required setback. 3. Dimensioned floor plans showing room layout/use, windows, doors, smoke detectors, light fixtures, and electrical switches and outlet locations. For room additions, provide existing building floor plan and the size and location of the existing window that adjoins the proposed addition. Use different legends for new versus existing construction. ---PAGE BREAK--- 200 S. Anaheim Blvd., Suite 145 Anaheim, California 92805 (714)765-5153 Phone (714)765-4607 Fax www.anaheim.net/building JAN 2018 B807 4. Roof plan with roofing material specified and roof pitch called out. 5. Building elevations and at least one longitudinal and one transverse building section. 6. On floor plans, show location of electrical outlets, plumbing fixtures, and mechanical units if used. For room additions, show method of providing heat to the addition. (Fireplace only is not an acceptable method of heating.) 7. Energy compliance forms CF-1R and MF-1R shall be made a part of the plan. 8. Structural foundation plan showing slab and footings. Provide foundation details and cross-reference them to the foundation plan. 9. Structural floor and roof framing plans showing floor/roof/ceiling member sizes and direction of span. Provide structural details and cross-reference them to floor and roof framing plans. 10. On foundation and floor framing plans, clearly show braced wall panels, its construction, nailing, and hold-down sizes.