Full Text
B B C C PLAN VIEW SECTION B-B SECTION C-C 1" MIN. HOLD DOWN 1" MIN. FRAME (RING) COVER 16 1 2" DETAIL ELECTRIC ANAHIEM 13 1 2" 13 3 4" 2" 18" 14" 20" 2" TYP. 4" 1 2" 23" END VIEW PLAN VIEW 19 3 4" 2" TYP. 26" 1 3 8" 10 1 4" POLYMER CONCRETE FRAME (RING) 9 7 8" 5 1 8" 1 1 2" 4 5 8" 23 1 2" 29 1 2" 13 3 4" 1 2 FLOATING NUT FOR 1 2" BOLT BOLT, PENTA HEAD " x REQ'D. LENGTH HOLD DOWN SEE DETAIL SIDE VIEW TYPICAL POLYMER CONCRETE COVER UPDATED MANUFACTURER TABLE RECESS FOR HOLD DOWN BOLT 2 PLACES FIBERGLASS REINFORCED BOX 23 1 4" SCOPE: THIS STANDARD SHOWS DETAILS, SPECIFICATIONS, AND ORDERING INFORMATION FOR APPROVED 13"x24" FIBERGLASS REINFORCED OR PLASTIC (HDPE) PULL BOX FOR USE ON CITY ELECTRIC DISTRIBUTION, STREET LIGHTING AND TELECOMMUNICATIONS SYSTEMS. ALSO, THIS STANDARD SHOWS PULL BOXES AND COVERS OF VARIOUS MATERIALS NOW DESIGNATED FOR MAINTENANCE ONLY. CAUTION: FIBERGLASS REINFORCED PULL BOX WITH POLYMER CONCRETE COVER SUITABLE FOR LANDSCAPE LOCATIONS OR LOCATIONS THAT MAY SEE OCCASIONAL NON-DELIBERATE TRAFFIC. APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : 13" X 24" PULL BOX AND COVER DETAILS CU 1500-1A REV8 8 09-22 1 4 CU 1500-1A TYPICAL FIBERGLASS REINFORCED BOX ---PAGE BREAK--- PLAN VIEW 1 3 8" 1 2" SECTION B-B 10 1 4" 4" 23" 19 3 4" ANAHIEM ELECTRIC B PLAN VIEW C 1" MIN. B SECTION C-C 2" END VIEW 20" BOX 1" MIN. 14" COVER 2" TYP. C 9 7 8" 5 1 8" 1 1 2" 4 5 8" HOLD DOWN SEE DETAIL BOLT, PENTA HEAD 1 2" x REQ'D. LENGTH FLOATING NUT FOR 1/2" BOLT HOLD DOWN DETAIL 23 1 2" 15" 26" 2" TYP. 29 1 2" 13 3 4" UPDATED MANUFACTURER TABLE 16 1 2" 13 3 4" 13 1 2" 23 1 4" APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : 13" X 24" PULL BOX AND COVER DETAILS CU 1500-1A REV8 8 09-22 2 4 CU 1500-1A CAUTION: PLASTIC (HDPE) PULL BOX AND COVER SUITABLE FOR LANDSCAPE LOCATIONS ONLY. SIDE VIEW TYPICAL PLASTIC (HDPE) COVER TYPICAL PLASTIC (HDPE) BOX ---PAGE BREAK--- 4" 12" MIN. UPDATED MANUFACTURER TABLE MAT'L TYPE MANUFACTURER & CATALOG NO. ANAHEIM PART NO. COMPATIBLE UNITS ARMORCAST CDR CARSON NEWBASIS SYNERTECH MARTIN FIBERGLASS REINFORCED BOX W/POLY CONCRETE COVER. 18" DEEP PULL BOX W/COVER A6001946TAX18 PA12-1324-18 - FCA132418T-90015 S1324B18AA 132418FRP-COA 486290 PB13X24POLY COVER ONLY A6001969 - - PCC1324A1G20 S1324HBB0A 1324PC-COA 486295 PB13X24CVR WEIGHT # BOX/COVER 45/33 - - 45/35 65/30 56/44 - - PLASTIC (HDPE) 15" DEEP PULL BOX W/COVER - - 1324-15-3B - - 486025 PBPLAS13X24 COVER ONLY - - 1324-3PB - - 486005 PBPLAS13X24CVR WEIGHT # BOX/COVER - - 20/6 - - - - CONCRETE COLLAR (FLUSH W/TOP) CONCRETE OR ASPHALT SURFACE (VEHICLE ACCESS) FIBERGLASS REINFORCED BOX ONLY APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : 13" X 24" PULL BOX AND COVER DETAILS CU 1500-1A REV8 8 09-22 3 4 CU 1500-1A NOTES: A. FIBERGLASS REINFORCED PULL BOX W/ POLYMER CONCRETE COVER SHALL BE 20,000# LOAD RATED AND MEET APPLICABLE REQUIREMENTS OF WESTERN UNDERGROUND COMMITTEE (WUC) GUIDE 3.6. B. PLASTIC (HDPE) PULL BOX & COVER SHALL BE 300# LOAD RATED (ASTM C857, A-0.3) AND MEET APPLICABLE REQUIREMENTS OF WUC GUIDE 3.6. C. COVERS SHALL BE FASTENED TO THE BOX USING TWO, 1/2"-13 UNC (UNIFIED NATIONAL COARSE) BY REQUIRED LENGTH NON-CORROSIVE PENTA-HEAD BOLTS. D. ALL COVERS SHALL CONFORM TO DIMENSIONS SHOWN AND BE INTERCHANGEABLE WITH ALL OTHER BOXES OF THE SAME SIZE AND MATERIAL MANUFACTURED PER THIS STANDARD E. FIBERGLASS REINFORCED PULL BOX SHALL BE SUITABLE FOR DIRECT BURIED INSTALLATION IN NATIVE SOIL (COMPACTED TO 95%) OR, EMBEDDED WITHIN CONCRETE OR ASPHALT SURFACE. WHEN EMBEDDED WITHIN CONCRETE OR ASPHALT SURFACE (OCCASIONAL TRAFFIC), A CONCRETE COLLAR 12" WIDE x 4" MINIMUM THICKNESS SHALL BE INSTALLED PER DETAIL BELOW. CONCRETE COLLAR DETAIL (NOTE E) ---PAGE BREAK--- APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : 13" X 24" PULL BOX AND COVER DETAILS CU 1500-1A REV8 8 09-22 4 4 CU 1500-1A NOTES: (CONTINUED) F. ALL COVERS SHALL HAVE HIGH COEFFICIENT OF FRICTION (EQUAL TO OR BETTER THAN 0.65), SLIP-RESISTANT SURFACE. G. COVER AND EXPOSED PORTIONS OF FIBERGLASS REINFORCED BOX SHALL BE CONCRETE COLOR. H. PLASTIC (HDPE) PULL BOX AND COVER SHALL BE GREEN COLOR. J. COVER MUST HAVE "ANAHEIM ELECTRIC" OR "ANAHEIM TELECOMM" IDENTIFICATION. K. BOX BODY AND COVER MUST BE LABELED WITH MANUFACTURER'S NAME AND CATALOG NUMBER ON INSIDE SURFACE. L. EXTENSIONS OF SAME MATERIAL AND MANUFACTURER MAY BE USED TO BRING COVER ON EXISTING INSTALLATIONS TO A NEW FINISH GRADE. CONSULT ELECTRICAL ENGINEERING DIVISION FOR APPROVAL. APPLICATION: SELECTION OF THE CORRECT TYPE OF PULL BOX INVOLVES JUDGMENT, TAKING INTO ACCOUNT THE PRESENT AND FUTURE INTENDED TRAFFIC FOR THE AREA WHERE THE PULL BOX WILL BE INSTALLED. SUITABLE LOCATIONS FOR FIBERGLASS REINFORCED PULL BOXES ARE: SIDEWALKS; PEDESTRIAN TRAFFIC AREAS; LANDSCAPED AREAS; PARKWAY STRIPS ADJACENT TO CURBS; DRIVEWAYS; PARKING LOTS; COMMERCIAL/INDUSTRIAL AREAS. SUITABLE LOCATIONS FOR PLASTIC (HDPE) PULL BOXES ARE LANDSCAPED AREAS ONLY AWAY FROM VEHICLE TRAFFIC. ITEMS TO BE CONSIDERED IN SELECTION OF PULL BOXES ARE AS FOLLOW: A. NUMBER AND SIZE OF CABLES INVOLVED. B. LOCATION OF CONDUIT ENTRANCES, CABLE LAYOUT AND MINIMUM BENDING RADIUS OF CABLES. C. THESE PULL BOXES SHALL NOT BE USED FOR PRIMARY CABLES. D. DO NOT PAVE OVER COVER WHEN INSTALLED IN TRAFFIC AREAS.