← Back to Anaheim, CA

Document Anaheim_doc_a07c850fdb

Full Text

FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT T&D CONSTRUCTION STANDARDS SUB MAINT - - METHOD OF INSTALLING ARTIFICIAL IVY ON PADMOUNT CABINETS CO 114-12 REV 0 0 01-14 1 8 CO 114-12 THREE PHASE PMT SCOPE: THIS STANDARD SHOWS THE METHOD OF INSTALLATION OF ARTIFICIAL IVY ON PADMOUNT CABINETS. TRANSFORMER NUMBER (DO NOT COVER) WARNING SIGN (DO NOT COVER) DOOR HANDLE ANTI-TAMPER BOLT & LOCK ASSEMBLY (DO NOT COVER) SINGLE PHASE PMT RISER NUMBER (DO NOT COVER) SAFE WORKING CLEARANCE STICKER (DO NOT COVER) SAFE WORKING CLEARANCE STICKER (DO NOT COVER) A. TRANSFORMER PADMOUNT 6" ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP) EQUIPMENT NUMBER (EXAMPLE: 19076) (DO NOT COVER) RISER NUMBER (EXAMPLE: RC892) (DO NOT COVER) TRANSFORMER NUMBER (DO NOT COVER) WARNING SIGN (DO NOT COVER) DOOR HANDLE ANTI-TAMPER BOLT AND LOCK ASSEMBLY (DO NOT COVER) EQUIPMENT NUMBER (DO NOT COVER) COVER TOP (NOTE 4) COVER TOP (NOTE 4) ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT T&D CONSTRUCTION STANDARDS SUB MAINT - - METHOD OF INSTALLING ATIFICIAL IVY ON PADMOUNT CABINETS CO114-12 REV 0 0 01-14 2 8 CO 114-12 AUTO TRANSFER SWITCH DESIGNATION NUMBER (DO NOT COVER) ATS WARNING SIGN (REFER TO CO 170) (DO NOT COVER) B. AUTOMATIC TRANSFER SWITCH, PADMOUNT (AUTOMATIC TRANSFER SWITCH) SAFE WORKING CLEARANCE STICKER (DO NOT COVER) DOOR HANDLE ANTI-TAMPER BOLT AND LOCK ASSEMBLY (DO NOT COVER) CIRCUIT IDENTIFICATION (DO NOT COVER) PREFERRED/EMERGENCY IDENTIFICATION (DO NOT COVER) CIRCUIT IDENTIFICATION (DO NOT COVER) ATS XXX 6" ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) COVER TOP (NOTE 4) ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT T&D CONSTRUCTION STANDARDS SUB MAINT - - METHOD OF INSTALLING ARTIFICIAL IVY ON PADMOUNT CABINETS CO114-12 REV0 0 01-14 3 8 CO 114-12 WARNING SIGN (DO NOT COVER) WARNING SIGN (DO NOT COVER) CIRCUIT INTERRUPTER (CI) IDENTIFICATION - USE 212" LETTERS AND NUMERALS (DO NOT COVER) C. 15KV 600 AMP PADMOUNT LIVE FRONT FUSE CABINET (PMH) PADMOUNT CABINET IDENTIFICATION ON CENTER OF STREET SIDE - USE 2 1/2" LETTERS AND NUMERALS (DO NOT COVER) SAFE WORKING CLEARANCE STICKER. (DO NOT COVER) COMPARTMENT IDENTIFICATION USE 1" NUMBERS (DO NOT COVER) DOOR HANDLE ANTI-TAMPER BOLT AND LOCK ASSEMBLY (DO NOT COVER) ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) COVER TOP (NOTE 4) ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT T&D CONSTRUCTION STANDARDS SUB MAINT - - METHOD OF INSTALLING ARTIFICIAL IVY ON PADMOUNT CABINETS CO114-12 REV 0 0 01-14 4 8 CO 114-12 FRONT SIDE BACK SIDE PSC D. SWITCHED CAPACITOR BANK, PADMOUNT (PADMOUNTED SWITCHED CAPACITOR) SAFE WORKING CLEARANCE STICKER (DO NOT COVER) SAFE WORKING CLEARANCE STICKER (DO NOT COVER) EQUIPMENT NUMBER (EXAMPLE: 19076) (DO NOT COVER) ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) PSC NUMBER (EXAMPLE: PSC123) (DO NOT COVER) WARNING SIGN (DO NOT COVER) DOOR HANDLE ANTI-TAMPER BOLT AND LOCK ASSEMBLY (DO NOT COVER) WARNING SIGN (DO NOT COVER) DOOR HANDLE ANTI-TAMPER BOLT AND LOCK ASSEMBLY (DO NOT COVER) COVER TOP (NOTE 4) ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT T&D CONSTRUCTION STANDARDS SUB MAINT - - METHOD OF INSTALLING ARTIFICIAL IVY ON PADMOUNT CABINETS CO114-12 REV 0 0 01-14 5 8 CO 114-12 PMV WARNING SIGN (DO NOT COVER) PMV NUMBER (EXAMPLE: PMV 123) (DO NOT COVER) WARNING SIGN (DO NOT COVER) E. 15KV 600 AMP DEAD FRONT SWITCH (VFI), PADMOUNT DOOR HANDLE ANTI-TAMPER BOLT AND LOCK ASSEMBLY (PADMOUNTED VFI SWITCH) SAFE WORKING CLEARANCE STICKER (DO NOT COVER) DOOR HANDLE ANTI-TAMPER BOLT AND LOCK ASSEMBLY (DO NOT COVER) EQUIPMENT NUMBER (EXAMPLE: 19076) (DO NOT COVER) ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) COVER TOP (NOTE 4) ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT T&D CONSTRUCTION STANDARDS SUB MAINT - - METHOD OF INSTALLING ARTIFICIAL IVY ON PADMOUNT CABINETS CO114-12 REV 0 0 01-14 6 8 CO 114-12 LIFTING LUGS FRONT VIEW FUSE CABINET NUMBER (EX. DFC-001) (DO NOT COVER) WARNING SIGN (DO NOT COVER) DFC F. DISTRIBUTION FUSE CABINET (DISTRIBUTION FUSED CABINET) SAFE WORKING CLEARANCE STICKER (DO NOT COVER) XXX EQUIPMENT NUMBER (DO NOT COVER) ARTIFICIAL IVY (TYP.) ARTIFICIAL IVY (TYP.) (DO NOT COVER) COVER TOP (NOTE 4) * LIFTING EARS REMOVABLE DOOR HANDLE W/ PAD LOCK PROVISIONS (DO NOT COVER) RADIO ANTENNA OPTIONAL FRONT VIEW AC (AUTOMATION CABINET) COVER TOP (NOTE 4) COVER SIDES & BACK IF ACCESSIBLE COVER SIDES & BACK IF ACCESSIBLE ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT T&D CONSTRUCTION STANDARDS SUB MAINT - - METHOD OF INSTALLING ARTIFICIAL IVY ON PADMOUNT CABINETS CO114-12 REV 0 0 01-14 7 8 CO 114-12 ITEM# DESCRIPTION QTY. MANUFACTURER STOCK CODE CU MFR MODEL 1 ARTIFICIAL IVY AS NEEDED IVY-IT 2 WIRE TIE MOUNT AS NEEDED WELD MOUNT SYSTEM* AT-5 (BLACK) 3 ADHESIVE AS NEEDED WELD MOUNT SYSTEM* AT-2010 * FRONT SIDE WIRE TIE MOUNT 12" MAX (TYP) 12" MAX (TYP) TYPICAL WIRE-TIE-MOUNT APPLICATION GRID LINES (NOTE 15) ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT T&D CONSTRUCTION STANDARDS SUB MAINT - - METHOD OF INSTALLING ARTIFICIAL IVY ON PADMOUNT CABINETS CO114-12 REV 0 0 01-14 8 8 CO 114-12 NOTES: 1. ARTIFICIAL IVY SHOULD BE INSTALLED USING NON-INTRUSIVE MATERIAL, AND SHOULD LEAVE NO OR MINIMAL RESIDUE AFTER REMOVAL FROM EQUIPTMENT SURFACE. THE RESIDUE SHOULD BE REMOVABLE AND CLEANABLE WITHOUT LEAVING ANY MARK OR DAMAGE TO EQUIPMENT CABINET. 2. INSTALL ARTIFICIAL IVY ONLY ON SURFACES VISIBLE TO THE PUBLIC, UNLESS OTHERWISE APPROVED BY THE UTILITY INSPECTOR. INCLUDE TRANSFORMER OUTSIDE FINS. 3. DOOR SEAMS SHOULD NOT BE COVERED AND INSIDE OF CABINET SHOULD BE ACCESSIBLE FOR OPERATING AND MAINTAINING EQUIPMENT. 4. COVER TOP OF EQUIPMENT IF EQUIPMENT IS SHORTER THAN 4 FEET OR TOP IS REACHABLE FOR APPLYING GRAFFITI. 5. USE NYLON TIE WRAP WITH UV RATING TO INSTALL ARTIFICIAL IVY TO WIRE TIE MOUNT. 6. WASH EQUIPTMENT OFF OF LOOSE DIRT /SOOT ETC. (IF EQUIPMENT HAS RUST, HOLES, SHOWS ANY SIGNS OF OIL LEAKAGE, OR ANY OTHER DAMAGE OF ANY SORT REPORT IT TO CITY REPRESENTATIVE IMMEDIATELY). 7. PAINT OVER GRAFFITI MARKINGS WITH MUNSELL GREEN 7GY3.29/1.5 PAINT AS NEEDED. 8. APPLY/REPLACE ALL EQUIPMENT IDENTIFICATION MARKINGS, WARNING STICKERS, AND ANY OTHER LABELS THAT ARE REQUIRED. 9. PRIOR TO IVY INSTALLATION USE INFRA-RED GUN TO TAKE TEMPERATURE READINGS. 10. APPLY WIRE-TIE-MOUNT TO EACH OF THE FOUR SIDES AND TOP OF THE EQUIPMENT LESS THAN 12" APART AS NEEDED (THE NUMBER OF TABS VARIES DEPENDING ON THE SIZE OF THE EQUIPMENT). USE THE TWO PART EPOXY GLUE RECOMMENDED BY THE TAB MANUFACTULRER TO ADHERE TABS TO THE EQUIPMENT. 11. TRIM IVY TO DESIRED AND SHAPES TO EXPOSE ALL WARNING LABELS AND EQUIPMENT MARKINGS. 12. TRIM IVY FOR DOOR HANDLES AND TO ALLOW DOORS TO OPEN AND CLOSE WITHOUT INTERFERENCE. 13. APPLY ARTIFICIAL IVY BY CABLE TYING TO WIRE-TIE-MOUNTS APPLIED IN STEP 10, USING UV RATED CABLE TIES. 14. AFTER INSTALLATION OF IVY IS COMPLETE, TAKE ADDITIONAL TEMPERATURE READING ON ALL FOUR SIDES OF THE EQUIPMENT, RECORD READINGS. 15. TO PLACE WIRE-TIE-MOUNTS ACCURATELY IDENTIFY THEIR LOCATIONS BY DRAWING GRIDLINES AS SHOWN ON PAGE 6. *