← Back to Anaheim, CA

Document Anaheim_doc_766f07945f

Full Text

APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : DISTRIBUTION VAULT 8' x 20' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600-3H REV4 4 01-16 1 4 CU 1600-3H VAULT LOCATION STYLE JENSEN CAT. NO. UTILITY VAULT CAT. NO. ANAHEIM CU. NO. TRAFFIC TUB K820-FV112-163H COFA 820-114-T V8X20CONT SCOPE: THIS STANDARD SHOWS DETAILS OF 8' X 20' X 9'-4" DISTRIBUTION VAULT, PARKWAY AND TRAFFIC INSTALLED. NOTES (TYPICAL): A. THE STRUCTURE SHALL MEET THE APPLICABLE REQUIREMENTS OF THE LATEST REVISED EDITIONS OF THE FOLLOWING STANDARDS: ACI318, ASTM C-857 & AASHTO (WHICH INCLUDES AASHTO H-20 TRAFFIC WHEEL LOADING). B. FOR VAULT DESIGN PURPOSES, USE 3' GROUND WATER TABLE LEVEL. C. INTERIOR WALLS, CEILING, AND NECK SHALL BE PAINTED WITH 2 COATS FLAT WHITE PAINT. (FRAZEE #410 LATEX OR APPROVED EQUAL). D. ALL JOINTS SHALL BE GASKETED AND WATERTIGHT. E. EXCAVATIONS PER CU 1600-4B, MINIMUM SIZE: SEE MANUFACTURES SUGGESTED EXCAVATION SIZE. F. SEE CU 1600-4D FOR TYPICAL VAULT SETTING DETAILS. G. PANEL OR TUNNEL STYLE REQUIRE APPROVAL BY ELECTRICAL ENGINEERING DIVISION. H. TRAFFIC STYLE TO INCLUDE 2 ACCESS LADDER. J. FOR VAULT VENTING, SEE CU 1700-6. K. FOR SUMP PUMP INSTALLATION, SEE CU 1700-5. L. FOR VAULT IDENTIFICATION, SEE C0 114-10. MOVED PARKWAY STYLE TO MAINTENANCE TRAFFIC INSTALLATION ---PAGE BREAK--- APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : DISTRIBUTION VAULT 8' x 20' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600-3H REV4 4 01-16 2 4 CU 1600-3H ITEM (PER SIDEWALL): A. 6" DIAMETER PVC CONDUIT TERMINATORS - 24 REQD. B. 1" DIAMETER PVC GROUND WIRE SLEEVE - 2 REQD. C. 1" DIA. x 6" DOUBLE COIL INSERT, GALV., 10,000 LB. PULL CAPACITY - 6 REQD. D. 1k" x 1k" x 48" LG. UNISTRUT WITH SHORT SLOTS, GALV., WITH y" DIA. STAINLESS STEEL FASTENERS - 14 REQD. E. y" DIA. IMPERIAL I-5000 PLASTIC INSERT - 28 REQD. F. k" DIA. x 3j" NC THREADED INSERT, 2000 LB LOAD CAPACITY - 4 REQD. G. y" DIA. BRONZE GROUND INSERT, GROUND TO REINFORCEMENT BARS. - 2 REQD. H. 10" DIA. PLASTIC VENT COUPLING - 2 REQD. MOVED PARKWAY STYLE TO MAINTENANCE TYPICAL SIDEWALL INTERIOR ELEVATION ---PAGE BREAK--- APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : DISTRIBUTION VAULT 8' x 20' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600-3H REV4 4 01-16 3 4 CU 1600-3H ITEM (PER ENDWALL): A. 6" DIAMETER PVC CONDUIT TERMINATORS - 24 REQD. B. 1" DIAMETER PVC GROUND WIRE SLEEVE - 2 REQD. C. 1" DIA. x 6" DOUBLE COIL INSERT, GALV., 10,000 LB. PULL CAPACITY - 4 REQD. D. 1k" x 1k" x 48" LG. UNISTRUT WITH SHORT SLOTS, GALV., WITH y" DIA. STAINLESS STEEL FASTENERS - 4 REQD. E. y" DIA. IMPERIAL I-5000 PLASTIC INSERT - 8 REQD. F. k" DIA. x 3j" NC THREADED INSERT, 2000 LB LOAD CAPACITY - 1 REQD. H. 10" DIA. PLASTIC VENT COUPLING - 1 REQD. MOVED PARKWAY STYLE TO MAINTENANCE TYPICAL ENDWALL INTERIOR ELEVATION ---PAGE BREAK--- APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS PREP BY SYS PLN MGR SUB MAINT NEW SHEET NEW SHEET FILENAME: REVISION KEYS: ADDED / REVISED TEXT CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : DISTRIBUTION VAULT 8' x 20' x 9'-4" DEEP PARKWAY OR TRAFFIC INSTALLED CU1600-3H REV4 4 01-16 4 4 CU 1600-3H ITEM A. 1" DIAMETER COIL INSERT, GALV. - 8 REQD. B. k" DIA COPPER CLAD GROUND ROD, WELD TO REINFORCEMENT & PROJECT 3" MIN. - 2 REQD. C. 13" DIA. SUMP, 5" DEEP W/PLATE RECESS. L0CATE AS SHOWN. - 2 REQD. MOVED PARKWAY STYLE TO MAINTENANCE TYPICAL FLOOR VIEW CEILING VIEW