CITY OF ANAHEIM DRAINAGE MANUAL FOR PUBLIC AND PRIVATE DRAINAGE FACILITIES DIVISION III 36 AUGUST 2005 DIVISION III PUBLIC STORM DRAINAGE FACILITIES REQUIREMENTS ---PAGE BREAK--- CITY OF ANAHEIM DRAINAGE MANUAL FOR PUBLIC AND PRIVATE DRAINAGE FACILITIES DIVISION III 37 AUGUST 2005 TABLE OF CONTENTS DIVISION III PUBLIC STORM DRAINAGE FACILITIES REQUIREMENTS PAGE SECTION 1—DESIGN 38 ---PAGE BREAK--- CITY OF ANAHEIM DRAINAGE MANUAL FOR PUBLIC AND PRIVATE DRAINAGE FACILITIES DIVISION III 38 AUGUST 2005 SECTION 1 – DESIGN A. PIPE MATERIAL Pipe material for public storm drains within the City of Anaheim shall be Reinforced Concrete Pipe (RCP) only. B. MINIMUM PIPE DIAMETER The minimum pipe diameter for publicly maintained storm drains in the City of Anaheim shall be 24 inches for mainline storm drains, and 18 inches for lateral connections to mainline storm drains.