SCOPE: THIS STANDARD SHOWS SIZES AND TYPES OF CONDUITS APPROVED FOR USE ON THE CITY OF ANAHEIM'S U.G. ELECTRICAL SYSTEM, UNLESS OTHERWISE SPECIFIED ON THE WORK ORDER DRAWINGS. 2000 1000 500 350 4/0 1/0 #2 CABLE SIZE VOLTAGE 600 VOLTS VOLTAGE 6.9KV VOLTAGE 12KV 4" 4" 3" 3" 3" 6" 6" 4" 4" 4" 6" 4" 4" 4" 6" 6" VOLTAGE 69KV 6" GUIDE FOR CONDUIT SIZE-RISER-MINIMUM 750 4" 6" 6" 2000 1000 500 350 4/0 1/0 #2 4" 4" 3" 3" 3" 6" 6" 6" 4" 4" 4" 6" - 6" GUIDE FOR CONDUIT SIZE-DUCT BANKS-MINIMUM 750 4" 6" 6" - - - 4" 6" A. ALL PRIMARY RISER CONDUITS SHALL BE PVC, SCHEDULE 80, FOR THE FIRST 8 FEET FROM FINISHED GRADE, PVC SHEDULE 40 MINIMUM COULD BE USED FOR THE REST OF THE RISER. GALVANIZED STEEL CONDUITS ARE ACCEPTABLE WHEN SPECIFIED IN WORK ORDER DRAWING FOR THE FIRST B. ALL RISERS SHALL BE BUILT IN ACCORDANCE WITH THE CITY OF ANAHEIIM CONSTRUCTION STANDARD CO 1101 AND GO95 RULE 54.6E. C. PVC REDUCER, IF REQUIRED, WILL BE SPECIFIED BY T&D ENGINEERING FOR CONNECTION OF RISER TO THE UNDERGROUND CONDUIT. A. ALL PRIMARY AND SECONDARY CONDUITS SHALL BE MINIMUM DB-100, CONCRETE ENCASED PER CONSTRUCTION STANDARD CU 1600-4. PVC SCHEDULE 80 AND GALVANIZED STEEL CONDUITS ARE ACCEPTABLE WHEN SPECIFIED IN WORK ORDER DRAWINGS. B. ALL CONDUITS CROSSING RAILROAD TRACKS, FREEWAYS, FLOOD CONTROL CHANNELS AND OTHER MAJOR CROSSING SHALL BE INSTALLED IN RIGID GALVANIZED STEEL CONDUIT PER CONSTRUCTION STANDARD CU 1600-96E. C. CONDUITS INSTALLED FOR STREETLIGHTS AND SUMP PUMPS SHALL BE 2" MINIMUM PVC SCHEDULE 80. FOR ALL STREET CROSSINGS, MINIMUM 2" HOT DIPPED GALVANIZED CONDUIT SHALL BE INSTALLED. D. CONDUITS INSTALLED FOR CITY OF ANAHEIM FIBER OPTIC AND AUTOMATION SHALL BE 4" MINIMUM CABLE SIZE VOLTAGE 600 VOLTS VOLTAGE 6.9KV VOLTAGE 12KV VOLTAGE 69KV 4" 4" NOTES NOTES - - - - - - - - - - - - - - - - - - - - APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : FIELD MGR OPER. MGR T&D CONSTRUCTION STANDARDS APPROVED CONDUIT TYPES, SIZES, AND APPLICATION CU1600-4A REV 1 1 01-11 1 2 CU 1600-4A ---PAGE BREAK--- NOTES: ALL CONDUIT SHALL BE INSTALLED PER CITY SPECIFICATIONS AND SHALL BE WATERTIGHT. A. THE MINIMUM RADIUS FOR BENDS IS: 24" FOR 2" DIA. CONDUIT 36" FOR 3" DIA. CONDUIT 60" FOR 5" & 6" DIA. CONDUITS B. THE MINIMUM RADIUS FOR SWEEPS OF ALL SIZE CONDUITS IS 12'-6" FOR 12KV AND 25' FOR 69KV UNLESS OTHERWISE SPECIFIED ON WORK ORDER DRAWINGS. C. ALL COUPLINGS, ADAPTERS, SEGMENTS, END BELLS, ETC. SHALL BE STANDARD TYPES, RECOMMENDED BY THE MANUFACTURER AND APPROVED BY UTILITIES INSPECTORS. D. SHORT OF CONDUIT, PROPERLY COUPLED, MAY BE USED IN CONDUIT INSTALLATIONS TO FORM SWEEPS OF LARGER RADIUSES. THE MAXIMUM NUMBER OF SEGMENTS USED FOR 12’-6” RADIUS SWEEPS SHOULD BE LIMITED TO FOUR PIECES AND FOR 25’SWEEPS SHOULD BE LIMITED TO FIVE PIECES. THE MAXIMUM DEFLECTION PER LENGTH OF CONDUIT SHALL BE: 1/2" FOR LENGTH 2 12' AND SHORTER AND 1" FOR OVER 2 12'. E. PVC CONDUIT MUST BE MADE BY AN APPROVED MANUFACTURER. CONSULT THE ELECTRICAL ENGINEERING DIVISION OR UTILITIES INSPECTOR FOR NAMES OF APPROVED MANUFACTURERS. F. WHITE CONDUIT (WATER PIPE, ETC.) AND ABS CONDUIT ARE NOT ACCEPTABLE FOR USE ON CITY'S U.G. ELECTRICAL SYSTEM. G. SEE CU 1600-96M FOR SOLVENT CEMENT JOINING AND PVC PLASTIC CONDUIT INSTALLATION. H. ALL CONDUIT STUBOUTS SHALL BE CAPPED AND APPROVED 3M ELECTRONIC LOCATOR BALL SHALL BE INSTALLED. I. ALL SECONDARY CONDUIT UNDER ROADS AND DRIVEABLE AREAS AND ALL PRIMARY CONDUIT SHALL BE CONCRETE-ENCASED. FOR SECONDARY CONDUIT IN NON-DRIVEABLE AREAS, PVC SCH 80 OR HOT DIPPED GALVANIZED MAY BE USED UNLESS OTHERWISE SPECIFIED ON WORK ORDER DRAWINGS. J. MANUFACTURED CONDUIT SEGMENTS ARE AVILABLE IN 11° AND 22.5°. TYPE APPLICATION X CONDUIT MATERIAL, COLOR INCLUDES INTERMEDIATE METAL CONDUIT (IMC) CONCRETE ENCASED HOT DIPPED GALVANIZED STEEL POLYVINYL CHLORIDE (PVC) GREY DB-100 (MINIMUM) SCHEDULE 40 GUIDE FOR CONDUIT TYPE ANSI SPEC C80.1 SCHEDULE 80 X SEE NOTE I X X X X NON-CONCRETE ENCASED APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : FIELD MGR OPER. MGR T&D CONSTRUCTION STANDARDS APPROVED CONDUIT TYPES, SIZES, AND APPLICATION CU1600-4A REV 1 1 01-11 2 2 CU 1600-4A