Full Text
FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS SYS PLN MGR SUB MAINT N/A N/A PR. ELEC. ENG. 17" x 30" PULL BOX AND COVER DETAILS CU1500-1B REV10 10 4-3-2024 1 3 CU 1500-1B B B C C 1" MIN. 1" MIN. COVER ELECTRIC ANAHEIM 2" CAUTION: 18" 173 4" 233 4" 2" TYP. 4" 1 2" 301 4" 261 2" 2" TYP. 1 3 8" 131 2" FIBERGLASS REINFORCED BOX SCOPE: THIS STANDARD SHOWS DETAILS, SPECIFICATIONS, AND ORDERING INFORMATION FOR APPROVED 17"x30" FIBERGLASS REINFORCED PULL BOX FOR USE ON CITY'S ELECTRIC DISTRIBUTION, STREET LIGHTING AND TELECOMMUNICATIONS SYSTEMS. ALSO, THIS STANDARD SHOWS PULL BOXES AND COVERS OF VARIOUS MATERIALS NOW DESIGNATED FOR MAINTENANCE ONLY. FIBERGLASS REINFORCED PULL BOX WITH POLYMER CONCRETE COVER SUITABLE FOR LANDSCAPED LOCATIONS OR LOCATIONS THAT MAY SEE OCCASIONAL NON-DELIBERATE TRAFFIC. 13 1 4" 63 4" 11 2" 45 8" 303 4" 33 1 4" 363 4" PLAN VIEW SECTION B-B TYPICAL FIBERGLASS REINFORCED BOX SECTION C-C 201 4" 171 2" 171 2" 171 4" PLAN VIEW END VIEW 301 2" SIDE VIEW TYPICAL POLYMER CONCRETE COVER UPDATED MANUFACTURER TABLE BOLT, PENTA HEAD 1/2" x REQ'D. LENGTH FLOATING NUT FOR 1/2" BOLT HOLD DOWN SEE DETAIL HOLD DOWN DETAIL POLYMER CONCRETE FRAME (RING) RECESS FOR HOLD DOWN BOLT 2 PLACES ELECTRIC ANAHEIM 2" 4" 1 2" 301 4" 261 2" 1 3 8" 131 2" 171 2" 171 2" 171 4" PLAN VIEW END VIEW 301 2" RECESS FOR HOLD DOWN BOLT 2 PLACES TYPICAL POLYMER CONCRETE COVER WITH STEEL PLATE SIDE VIEW 1 8" STEEL PLATE ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS SYS PLN MGR SUB MAINT N/A N/A PR. ELEC. ENG. 17" x 30" PULL BOX AND COVER DETAILS CU1500-1B REV10 10 4-3-2024 2 3 CU 1500-1B 12" MIN. 12" NOTES: A. FIBERGLASS REINFORCED PULL BOX W/ POLYMER CONCRETE COVER SHALL BE 20,000# LOAD RATED AND MEETAPPLICABLE REQUIREMENTS OF WESTERN UNDERGROUND (WUC) GUIDE 3.6. B. COVERS SHALL BE FASTENED TO THE BOX USING TWO, 1/2"-13 UNC (UNIFIED NATIONAL COARSE) BY LENGTH REQUIRED NON-CORROSIVE PENTA-HEAD BOLTS. C. ALL COVERS SHALL CONFORM TO DIMENSIONS SHOWN AND BE INTERCHANGEABLE WITH ALL OTHER BOXES OF THE SAME SIZE AND MATERIAL MANUFACTURED PER THIS STANDARD. D. FIBERGLASS REINFORCED PULL BOX SHALL BE SUITABLE FOR DIRECT BURIED INSTALLATION IN NATIVE SOIL (COMPACTED TO 95%) OR, EMBEDDED WITHIN CONCRETE OR ASPHALT SURFACE. WHEN EMBEDDED WITH CONCRETE OR ASPHALT SURFACE (OCCASIONAL TRAFFIC, ALLEY WAY) A 4500 PSI CONCRETE COLLAR 12" WIDE AND 12" THICK SHOULD BE POURED ALL AROUND THE FRAME, CURE CONCRETE 3 DAYS BEFORE LOADING. UPDATED MANUFACTURER TABLE CONCRETE COLLAR (FLUSH W/TOP) CONCRETE OR ASPHALT SURFACE (VEHICLE ACCESS) FIBERGLASS REINFORCED BOX ONLY CONCRETE COLLAR DETAIL (NOTE D) MAT'L TYPE MANUFACTURER & CATALOG NO. ANAHEIM PART NO. COMPATIBLE UNITS ARMORCAST/ HUBBELL CDR/ HUBBELL MARTIN/ OLD CASTLE NEWBASIS FIBERGLASS REINFORCED BOX W/POLY CONCRETE COVER (18" DEEP) PULL BOX W/COVER A6001640TAX18 PA12-1730-18 173018FRP-COA FCA173018T-9000 8 486300 PB17X30POLY ELECTRIC COVER ONLY A6001947T 1730PC-COA PCC1730P1-90008 486305 PB17X30PCVR COMM COVER ONLY A6001947T-COA - PCC1730P1-90045 486325 - WEIGHT # BOX/COVER 56/50 - 95 /73 - - POLYMER CONCRETE COVER WITH STEEL PLATE BOXCOM COVER A6001947T-STL -PLATE-01 486375 ---PAGE BREAK--- FILENAME: REVISION KEYS: ADDED / REVISED TEXT NEW SHEET CONSTRUCTION STANDARD: ADDED / REVISED MATERIAL SHEET OF REVISION NO. ISSUE DATE : APPROVALS T&D MGR CITY OF ANAHEIM ELECTRICAL DIVISION PUBLIC UTILITIES DEPARTMENT OPS MGR T&D CONSTRUCTION STANDARDS SYS PLN MGR SUB MAINT N/A N/A PR. ELEC. ENG. 17" x 30" PULL BOX AND COVER DETAILS CU1500-1B REV10 10 4+3-2024 3 3 CU 1500-1B NOTES: (CONTINUED) E. POLYMER CONCRETE COVER SHALL HAVE HIGH COEFFICIENT OF FRICTION EQUAL TO OR BETTER THAN 0.65, SLIP-RESISTANT SURFACE. F. COVER AND EXPOSED PORTIONS OF FIBERGLASS REINFORCED BOX SHALL BE CONCRETE COLOR. G. PURCHASE ORDER SHALL SPECIFY COVER MARKING AS "ANAHEIM ELECTRIC" OR "ANAHEIM COMM". H. BOX BODY AND COVER MUST BE LABELED WITH MANUFACTURER'S NAME AND CATALOG NUMBER ON INSIDE SURFACE. J. EXTENSIONS OF SAME MATERIAL AND MANUFACTURER MAY BE USED TO BRING COVER ON EXISTING INSTALLATIONS TO A NEW FINISH GRADE. CONSULT ELECTRICAL ENGINEERING DIVISION FOR APPROVAL. SELECTION OF THE CORRECT TYPE OF PULL BOX INVOLVES JUDGMENT, TAKING INTO ACCOUNT THE PRESENT AND FUTURE INTENDED TRAFFIC FOR THE AREA WHERE THE PULL BOX WILL BE INSTALLED. SUITABLE LOCATIONS FOR FIBERGLASS REINFORCED PULL BOXES ARE: SIDEWALKS; PEDESTRIAN TRAFFIC AREAS; LANDSCAPED AREAS; PARKWAY STRIPS ADJACENT TO CURBS; DRIVEWAYS; PARKING LOTS; COMMERCIAL/INDUSTRIAL AREAS. ITEMS TO BE CONSIDERED IN SELECTION OF PULL BOXES ARE AS FOLLOW: A. NUMBER AND SIZE OF CABLES INVOLVED. B. LOCATION OF CONDUIT ENTRANCES, CABLE LAYOUT AND MINIMUM BENDING RADIUS OF CABLES. C. THESE PULL BOXES SHALL NOT BE USED FOR PRIMARY CABLES. D. DO NOT PAVE OVER COVER WHEN INSTALLED IN TRAFFIC AREAS. APPLICATION: UPDATED MANUFACTURER TABLE